Search: Posts Made By: backendcode
Forum: LIVE PLC Questions And Answers October 5th, 2018, 09:27 AM
Replies: 4
Views: 143
Posted By backendcode
dmroeder, That's what I realized now!! thank you...

dmroeder, That's what I realized now!! thank you for the help!
Forum: LIVE PLC Questions And Answers October 5th, 2018, 09:21 AM
Replies: 4
Views: 143
Posted By backendcode
Hey Ken, I did the reset using menu button....

Hey Ken,
I did the reset using menu button. However, I tried the different Ethernet cable and I can see the IP address now.

Quick question, when I don't connect Ethernet cable to my PV+, the IP...
Forum: LIVE PLC Questions And Answers October 5th, 2018, 08:59 AM
Replies: 4
Views: 143
Posted By backendcode
Assigned an IP address to panel view but disappear after restart

Hello Experts,

I have a question, I am programming AB HMI and i assigned an IP address yesterday, but when I came to work this morning and grabbed my HMI to work on it, there was no IP address to...
Forum: LIVE PLC Questions And Answers October 1st, 2018, 09:44 AM
Replies: 2
Views: 132
Posted By backendcode
Thank you garry!

Thank you garry!
Forum: LIVE PLC Questions And Answers October 1st, 2018, 07:22 AM
Replies: 2
Views: 132
Posted By backendcode
.apa file is not a valid archive file (Need help)

Good Morning Everyone,

I know this question has been asked many times on this forum but honestly, I couldn't find the answer. So I have .apa file which I received from customer and I do want to...
Forum: LIVE PLC Questions And Answers September 24th, 2018, 10:43 AM
Replies: 0
Views: 74
Posted By backendcode
Festo fb-36 configuration

Hello All,

I have Festo FB-36 hardware and I configured it with Generic Ethernet module in my AB PLC. But I noticed that there is another way to configure FB-36 module by using CPX-FB36...
Forum: LIVE PLC Questions And Answers August 25th, 2018, 07:11 AM
Replies: 2
Views: 432
Posted By backendcode
Hi Ken, Thank you for the reply. So I am...

Hi Ken, Thank you for the reply.

So I am getting two fault

16#0204
16#0203

It disconnect first, attempt to reconnect and make a connection again and then connection sustain for a while...
Forum: LIVE PLC Questions And Answers August 24th, 2018, 08:48 PM
Replies: 2
Views: 432
Posted By backendcode
Turck I/O block communication fault

Hello Expert,
I am just wondering if someone can help me with my current situation.

I have 5 robots controlled by 1 Allen Bradley PLC. It's a material handling application so each robot has a...
Forum: LIVE PLC Questions And Answers August 10th, 2018, 06:44 PM
Replies: 9
Views: 443
Posted By backendcode
Thank you Ken, I was more concerned about CIP...

Thank you Ken, I was more concerned about CIP connection because the controller we have right now is almost running out of CIP connection and sometimes we can't get online to the controller so we...
Forum: LIVE PLC Questions And Answers August 10th, 2018, 09:25 AM
Replies: 9
Views: 443
Posted By backendcode
You are correct! My bad I get confused with bytes...

You are correct! My bad I get confused with bytes and bits lol but yes you are right!

Thank you for suggestion and correcting me :)
Forum: LIVE PLC Questions And Answers August 10th, 2018, 08:54 AM
Replies: 9
Views: 443
Posted By backendcode
Thank you Jason for the AB manual link, So...

Thank you Jason for the AB manual link,

So I am limited to use SINT datatype with maximum 3 elements of an array to fall under the 500 bytes range


On my concern related to CIP connection,...
Forum: LIVE PLC Questions And Answers August 10th, 2018, 07:24 AM
Replies: 9
Views: 443
Posted By backendcode
Produced/Consumed tag and CIP connection

Hello Experts,

I would like to ask a general question and just wondering if someone can help me to explain it.

So I have a AB Compact logix processor on my main control panel and I am talking...
Forum: LIVE PLC Questions And Answers June 23rd, 2018, 10:00 PM
Replies: 2
Views: 253
Posted By backendcode
Hey do you need help to write PMC ladder for this...

Hey do you need help to write PMC ladder for this logic or wiring diagram of X AND Y signals from external machines to PMC and from PMC to a robot?

Thanks,
Forum: LIVE PLC Questions And Answers June 7th, 2018, 10:48 PM
Replies: 4
Views: 386
Posted By backendcode
Thank you jstolaruk, I was thinking about it...

Thank you jstolaruk,

I was thinking about it but then if I need to send 10 character string which is 10 bytes so I might be ended up using 80 bits point on I/O card in ABB controller which is a...
Forum: LIVE PLC Questions And Answers June 7th, 2018, 03:02 PM
Replies: 4
Views: 386
Posted By backendcode
Send a string from Allen Bradley to ABB robot

Hello Everyone,

I want to send a string from AB PLC to ABB robot control. I can send integers from PLC to abb robot using group input but not sure how can I send a string with a handshake.

Any...
Forum: LIVE PLC Questions And Answers June 2nd, 2018, 10:11 PM
Replies: 8
Views: 614
Posted By backendcode
Thank you for the forum link :)

Thank you for the forum link :)
Forum: LIVE PLC Questions And Answers June 2nd, 2018, 09:15 PM
Replies: 8
Views: 614
Posted By backendcode
hahah good one!

hahah good one!
Forum: LIVE PLC Questions And Answers June 2nd, 2018, 09:11 PM
Replies: 8
Views: 614
Posted By backendcode
Thank you for the valuable input :) I will...

Thank you for the valuable input :) I will definitely think about your input and i liked the idea too :)

Thank you again,
Forum: LIVE PLC Questions And Answers June 2nd, 2018, 05:02 PM
Replies: 8
Views: 614
Posted By backendcode
Jstolaruk, Thank you for the reply. I think...

Jstolaruk,

Thank you for the reply. I think we have a pretty much same method and I would say this is the very common method used in industry and robot always wait for PLC move command and do the...
Forum: LIVE PLC Questions And Answers June 2nd, 2018, 02:52 PM
Replies: 8
Views: 614
Posted By backendcode
Any Robot Programmer here to discuss auto recovery

Hello All,

I would like to know how do you guys write a program to do auto recovery at the cell.

Currently, at my workplace, we use ABB robots and most of the cell have auto recovery...
Forum: LIVE PLC Questions And Answers May 16th, 2018, 09:28 PM
Replies: 15
Views: 1,652
Posted By backendcode
Peter Nachtwey, You are absolutely correct! Even...

Peter Nachtwey, You are absolutely correct! Even though I have been involved in some sort of data collection projects and once you have data, how do you use that data is very important.

Data can...
Forum: LIVE PLC Questions And Answers May 16th, 2018, 09:07 PM
Replies: 15
Views: 1,652
Posted By backendcode
Hey Maxkling, You mentioned very valid...

Hey Maxkling,

You mentioned very valid points and I agree with you that business intelligence is a very big deal but I have a general thought in the manufacturing industry who use automation for...
Forum: LIVE PLC Questions And Answers May 16th, 2018, 08:50 PM
Replies: 15
Views: 1,652
Posted By backendcode
Hey cardosocea, The most important thing I...

Hey cardosocea,

The most important thing I believe is to capture the important information from the production line and what information will help us in future if we use that information is the...
Forum: LIVE PLC Questions And Answers May 16th, 2018, 02:09 PM
Replies: 15
Views: 1,652
Posted By backendcode
Internet of Thing (IoT) in manufacturing industry

Hello Everyone, I would like to talk about Internet of things in Manufacturing industry and would love to know your opinion because I have plan to start my company to implement IoT which will help...
Forum: LIVE PLC Questions And Answers May 15th, 2018, 09:03 AM
Replies: 12
Views: 631
Posted By backendcode
Hey MikeyN, Thank you for the great advice. Yes,...

Hey MikeyN, Thank you for the great advice. Yes, I am using GSV to get the system time and value and Please look into my above reply and counter is working too and I am planing to use FIFO and use an...