Search: Posts Made By: NetNathan
Forum: LIVE PLC Questions And Answers October 20th, 2018, 10:03 PM
Replies: 6
Views: 301
Posted By NetNathan
I have used the VersaMax Micro on a few small...

I have used the VersaMax Micro on a few small jobs.
Compact unit and it is nice that it works with Machine edition also.

It can be expanded to cover a fair amount of IO.

It is listed as a...
Forum: LIVE PLC Questions And Answers October 17th, 2018, 12:47 AM
Replies: 7
Views: 183
Posted By NetNathan
Yep....but when the cap dies so does the logic. ...

Yep....but when the cap dies so does the logic.

You could use the PROM in the 90-30 set to load logic on power up....then you would not even need battery. BUT.... you need to remember to save to...
Forum: LIVE PLC Questions And Answers October 16th, 2018, 10:45 PM
Replies: 7
Views: 183
Posted By NetNathan
If you lose the program in the 90-30, it will...

If you lose the program in the 90-30, it will revert to a default program named "HHP". This may be why you found the program name did not match the name stored in the CPU.
If it happens during a...
Forum: LIVE PLC Questions And Answers October 10th, 2018, 12:01 AM
Replies: 4
Views: 240
Posted By NetNathan
I found plc software manual... Here is link to...

I found plc software manual...
Here is link to 623-60 software manual.
Maybe this will help you find software.
https://app.box.com/s/y0zp4xrvbuoaq0p2vuqglckyz7qom321
Forum: LIVE PLC Questions And Answers October 9th, 2018, 06:04 PM
Replies: 4
Views: 240
Posted By NetNathan
Yes that is the gateway.. I used to have...

Yes that is the gateway..


I used to have a copy of the software....I will have to dig thru my archives....no promises.
What was your customer using these PLCs for, did they have a Scada/HMI...
Forum: LIVE PLC Questions And Answers October 9th, 2018, 05:46 AM
Replies: 19
Views: 526
Posted By NetNathan
You could use pressure switches on the air valve...

You could use pressure switches on the air valve outputs to monitor state...
Forum: LIVE PLC Questions And Answers October 9th, 2018, 04:04 AM
Replies: 4
Views: 240
Posted By NetNathan
That is the OLD Honeywell Series 9000...

That is the OLD Honeywell Series 9000 software....late 1980s to early 1993 or so.
Those were actually "York" plcs (bought by Honeywell), pretty good in their day.

You will need Honeywell S9000...
Forum: LIVE PLC Questions And Answers September 29th, 2018, 03:36 PM
Replies: 18
Views: 677
Posted By NetNathan
I have heard good things about Phoenix Contact...

I have heard good things about Phoenix Contact "mGuard"....
Forum: LIVE PLC Questions And Answers September 28th, 2018, 10:01 AM
Replies: 27
Views: 1,593
Posted By NetNathan
I did forget to add the part about the cost of...

I did forget to add the part about the cost of post sales support....
Forum: LIVE PLC Questions And Answers September 28th, 2018, 09:58 AM
Replies: 5
Views: 362
Posted By NetNathan
Thanks all...

Thanks all...
Forum: LIVE PLC Questions And Answers September 27th, 2018, 03:20 PM
Replies: 27
Views: 1,593
Posted By NetNathan
Especially since.... Most contracts are...

Especially since....
Most contracts are regrettably sent to the lowest bidder...
Not the most knowledgeable or with the best capabilities....... just lowest price...
Forum: LIVE PLC Questions And Answers September 27th, 2018, 02:11 PM
Replies: 27
Views: 1,593
Posted By NetNathan
There is a point.....I believe it is $100,000 a...

There is a point.....I believe it is $100,000 a year and Automation Direct will give you a better discount.

It is ludicrous to me why so many people do not understand markup on selling...
Forum: LIVE PLC Questions And Answers September 27th, 2018, 01:31 PM
Replies: 5
Views: 362
Posted By NetNathan
24VDC and 110VAC in same conduit

I have some 24VDC contact signals and 115VAC to the coil of a contactor to go to an enclosure.
Is there anything wrong with running the 115VAC with the 24VDC in same conduit? I don't really want...
Forum: LIVE PLC Questions And Answers September 26th, 2018, 06:32 PM
Replies: 12
Views: 792
Posted By NetNathan
Great info...

Great info...
Forum: LIVE PLC Questions And Answers September 9th, 2018, 07:00 AM
Replies: 7
Views: 492
Posted By NetNathan
Seal the antenna/device in a plastic shell? ...

Seal the antenna/device in a plastic shell?

Anybus Bolt for Ethernet or AnyBus Wireless Bridge for Ethernet, Ethernet I/P, Modbus TCP, Profinet...etc?
...
Forum: LIVE PLC Questions And Answers September 7th, 2018, 09:53 PM
Replies: 5
Views: 508
Posted By NetNathan
Are you floating the DC supply? Try grounding...

Are you floating the DC supply?
Try grounding the DC-.
Forum: LIVE PLC Questions And Answers September 6th, 2018, 03:30 AM
Replies: 15
Views: 622
Posted By NetNathan
Maybe IFM-Efector BUT..you will have to add a...

Maybe IFM-Efector
BUT..you will have to add a disk with trigger points on it to the shaft.

DI0101 (Compact evaluation unit for speed monitoring)
https://www.ifm.com/us/en/product/DI0101
...
Forum: LIVE PLC Questions And Answers September 5th, 2018, 06:43 AM
Replies: 1
Views: 181
Posted By NetNathan
GE RX3i Rate of Change logic

Does GE RX3i have a "Rate of Change" FBD or?

I need to alarm on an analog signal that changes to fast or "Spikes".
Forum: LIVE PLC Questions And Answers August 29th, 2018, 05:08 PM
Replies: 14
Views: 1,133
Posted By NetNathan
We started using the Dell Embedded Box PC. It...

We started using the Dell Embedded Box PC.
It can be ordered with din rail mount and connections for remote control.
It is 24VDC and fanless.
...
Forum: LIVE PLC Questions And Answers August 24th, 2018, 05:59 PM
Replies: 79
Views: 8,141
Posted By NetNathan
I still work on a few of these....customer slow...

I still work on a few of these....customer slow to upgrade due to original cost involved on the PLC3, they want to get maximum ROI.
We actually supplied equipment with the PLC3 CPU rack being more...
Forum: LIVE PLC Questions And Answers August 21st, 2018, 01:32 PM
Replies: 7
Views: 521
Posted By NetNathan
Thanx guys... As I suspected, they are rarely...

Thanx guys...
As I suspected, they are rarely individually fused. (I have never had one "short" in many years)
I will still fuse in groups of 5.
Forum: LIVE PLC Questions And Answers August 21st, 2018, 10:30 AM
Replies: 7
Views: 521
Posted By NetNathan
Fusing of signal conditioners?

I have a job that involves 20 signal conditioners (voltage and amperage to 4-20mA)...

Should I fuse the 24vdc power to each one? I would prefer groups of 5.
Never really had a signal...
Forum: LIVE PLC Questions And Answers August 19th, 2018, 02:39 PM
Replies: 10
Views: 970
Posted By NetNathan
Are you reading the same TC with the PLC and the...

Are you reading the same TC with the PLC and the instrument?
Sometimes the way the device detects an "open Thermocouple" condition causes interference in the reading in the other device.
Also the...
Forum: LIVE PLC Questions And Answers August 17th, 2018, 09:35 PM
Replies: 14
Views: 808
Posted By NetNathan
Maybe he can lay this in the enclosure to limit...

Maybe he can lay this in the enclosure to limit temperature rise...
Aerogel is pretty cool. My company is testing some blankets now.

https://youtu.be/pvppTY_Vdm4
Forum: LIVE PLC Questions And Answers August 17th, 2018, 10:55 AM
Replies: 13
Views: 615
Posted By NetNathan
The pain,... Here are 2 sites with different...

The pain,...
Here are 2 sites with different calculations.....ARGHHHH

https://1xtechnologies.com/mm-to-awg/

https://muellergroup.net/technical/metric-awg-to-mm2-conversion-chart/