Search: Posts Made By: JeffKiper
Forum: LIVE PLC Questions And Answers May 12th, 2018, 06:58 AM
Replies: 6
Views: 537
Posted By JeffKiper
OK shameless plug for my shop. I'm just outside...

OK shameless plug for my shop. I'm just outside of Louisville Ky. Not to far from you ,from what I recall.
Forum: LIVE PLC Questions And Answers April 2nd, 2018, 09:18 AM
Replies: 11
Views: 458
Posted By JeffKiper
I'm uninstalling Adobe Acrobat Reader DC now....

I'm uninstalling Adobe Acrobat Reader DC now. Thank you sir.
Forum: LIVE PLC Questions And Answers April 2nd, 2018, 09:00 AM
Replies: 11
Views: 458
Posted By JeffKiper
Studio 5000 version 30 looooong upload time

Is anyone else having a long time uploading from controllers on version 30?
I have a 1756-L81 with 877,591 block used of 3,145,728 available. I have connected to the controller from several...
Forum: LIVE PLC Questions And Answers January 29th, 2018, 11:02 AM
Replies: 21
Views: 1,341
Posted By JeffKiper
VFD disconnect aux contacts

Is there an electrical code requirement that calls out the a need for an auxiliary contact in a field mounted disconnect?
I have a customer that doesn't want to put auxiliary contact in the field...
Forum: LIVE PLC Questions And Answers November 11th, 2017, 08:39 AM
Replies: 24
Views: 1,714
Posted By JeffKiper
I had a guy try to get me to sign a non-compete...

I had a guy try to get me to sign a non-compete and non-disclosure. I'm find with non-disclosures. This guy tried to make it once I use a specific model controller for him I couldn't use it for...
Forum: LIVE PLC Questions And Answers November 8th, 2017, 06:38 AM
Replies: 24
Views: 1,504
Posted By JeffKiper
Be careful those are the ones that always scare...

Be careful those are the ones that always scare me. The one that you know you're going to have to watch the budget on is okay.
Forum: LIVE PLC Questions And Answers May 13th, 2017, 04:59 AM
Replies: 2
Views: 1,548
Posted By JeffKiper
Yes MR configurator 2 is what I had to have when...

Yes MR configurator 2 is what I had to have when I was troubleshooting a J4 servo last month. Not the best software but not the worst either.
Forum: LIVE PLC Questions And Answers May 3rd, 2017, 11:33 AM
Replies: 53
Views: 3,215
Posted By JeffKiper
That firmware is only available on the second...

That firmware is only available on the second blue moon of the year that falls on a leap year
Forum: LIVE PLC Questions And Answers May 3rd, 2017, 11:24 AM
Replies: 53
Views: 3,215
Posted By JeffKiper
Thanks Dustin.

Thanks Dustin.
Forum: LIVE PLC Questions And Answers May 3rd, 2017, 11:18 AM
Replies: 53
Views: 3,215
Posted By JeffKiper
I sent phil a pm

I sent phil a pm
Forum: LIVE PLC Questions And Answers April 28th, 2017, 06:00 AM
Replies: 9
Views: 1,110
Posted By JeffKiper
I agree with JesperMP you may want to look at...

I agree with JesperMP you may want to look at migrating away from the existing HMI na dave a new system build. There are alot of folks around that can do that migration for you. I am not aware of any...
Forum: LIVE PLC Questions And Answers April 27th, 2017, 09:21 PM
Replies: 3
Views: 402
Posted By JeffKiper
I have seen several roller coasters that where...

I have seen several roller coasters that where either no safety or safety to the max. Most State ride inspectors never look at the controls.
Forum: LIVE PLC Questions And Answers April 27th, 2017, 09:19 PM
Replies: 3
Views: 402
Posted By JeffKiper
I am a safety geek. So keep that in mind. I have...

I am a safety geek. So keep that in mind. I have been called several time to look at safety jobs where good "old joe relay" has made it safe .
I went on a job a once and they use safety contactors...
Forum: LIVE PLC Questions And Answers April 25th, 2017, 06:49 PM
Replies: 31
Views: 2,140
Posted By JeffKiper
Sifis Rockwell doesn't allow others to distribute...

Sifis Rockwell doesn't allow others to distribute their firmware. There is no revision control when you get this code from others.
I would probably call my local AB distributor, or if you have a...
Forum: LIVE PLC Questions And Answers April 7th, 2017, 03:07 AM
Replies: 8
Views: 1,117
Posted By JeffKiper
Guy you know sometimes the trees get I the way of...

Guy you know sometimes the trees get I the way of the forest. That little digital angle gauge makes life simple. These benders are basically conduit benders.
Forum: LIVE PLC Questions And Answers April 4th, 2017, 04:39 PM
Replies: 8
Views: 1,117
Posted By JeffKiper
What display can I put on an Arduino

What display can I put on an Arduino
Forum: LIVE PLC Questions And Answers April 1st, 2017, 07:42 AM
Replies: 20
Views: 2,821
Posted By JeffKiper
I drill the hole and thread forming screws. We...

I drill the hole and thread forming screws. We don't use thread cutting screws. The screws are truss head ornpan head I can't remember. We buy 10k at a time.
Forum: LIVE PLC Questions And Answers April 1st, 2017, 07:22 AM
Replies: 24
Views: 1,951
Posted By JeffKiper
Customer called and said the plc doesn't work...

Customer called and said the plc doesn't work anymore. I get onsite and pull and tug wires. 3 wire prox is sending a signal to the PLC . NO light on that input. So bad input I ASSuME. After changing...
Forum: LIVE PLC Questions And Answers March 31st, 2017, 11:22 PM
Replies: 8
Views: 1,117
Posted By JeffKiper
Angle display

I have a bender that is a dumb induction motor running a gear back and forth to bend the material. The operator has a small tick mark that they bend to. They want a angle display. I'm looking for a...
Forum: LIVE PLC Questions And Answers March 26th, 2017, 12:30 PM
Replies: 7
Views: 799
Posted By JeffKiper
DanW look at those premade Banner enclosures....

DanW look at those premade Banner enclosures. They are the PM kits bound and ready to go. You have to provide 120 VAC and connect your I/O.
Forum: LIVE PLC Questions And Answers March 6th, 2017, 07:16 PM
Replies: 15
Views: 1,920
Posted By JeffKiper
++++ whatever number you need it to be. You...

++++ whatever number you need it to be. You "shall" preform a risk assesment per ANSI, OSHA, RIA..... "SHALL" is their way of telling you ,you will do this. If you don't do a risk assesment and show...
Forum: LIVE PLC Questions And Answers February 18th, 2017, 01:00 AM
Replies: 6
Views: 1,204
Posted By JeffKiper
Look at Red Lion as a communication bridge they...

Look at Red Lion as a communication bridge they have a native driver
Forum: LIVE PLC Questions And Answers February 18th, 2017, 12:26 AM
Replies: 2
Views: 861
Posted By JeffKiper
Make sure your on the local directory. It fails...

Make sure your on the local directory. It fails on a network just about every time.
Forum: LIVE PLC Questions And Answers December 25th, 2016, 12:45 PM
Replies: 5
Views: 1,479
Posted By JeffKiper
Banner engineering. Their thermocouple modules...

Banner engineering. Their thermocouple modules are MV.
Forum: LIVE PLC Questions And Answers November 24th, 2016, 09:14 PM
Replies: 15
Views: 3,116
Posted By JeffKiper
BachPhi are you porting the PCMK car to you...

BachPhi are you porting the PCMK car to you Virtual machine?