Forum: LIVE PLC Questions And Answers
November 11th, 2010, 06:18 PM
|
Replies: 1
Views: 1,783
sm@rt access tutorial
Hi!!
im making the winccflexible-gettingstartedoptions tutorial to connect to hmi via sm@rt access and im get stucked in this step.
I really donīt know where do i need to make this, i canīt found...
|
Forum: LIVE PLC Questions And Answers
November 3rd, 2010, 02:48 PM
|
Replies: 0
Views: 1,748
microwin step7 tags on step7
hi to all!
I would like to know if you can use symbols on step7microwin and use them on step7 and be synchronized, like when you integrate an Winccflexible project on step7.
cheers!
|
Forum: LIVE PLC Questions And Answers
October 29th, 2010, 07:46 PM
|
Replies: 1
Views: 3,661
|
Forum: LIVE PLC Questions And Answers
October 27th, 2010, 12:42 PM
|
Replies: 3
Views: 2,762
|
Forum: LIVE PLC Questions And Answers
October 24th, 2010, 03:53 PM
|
Replies: 3
Views: 2,762
wincc flexible 2008 and s7
hi to all!
i am reading some manuals about wincc and they only make panel operators tutorials, i would like to know if someone has experience with pc/plc scada. I just want, for example, to create a...
|
Forum: LIVE PLC Questions And Answers
October 21st, 2010, 04:54 PM
|
Replies: 3
Views: 1,361
|
Forum: LIVE PLC Questions And Answers
October 19th, 2010, 08:07 PM
|
Replies: 3
Views: 1,361
interfacing siemens plc with lookout
hi to all,
im new with scada and wanted to connect the plc s7-300 with a hmi with lookout from ni. has anyone experience with this?
thanks to all.
|
Forum: LIVE PLC Questions And Answers
September 30th, 2010, 04:26 PM
|
Replies: 4
Views: 4,359
thanks KalleOlsen for the answer, but i just...
thanks KalleOlsen for the answer, but i just found the method of access (token ring, polling) depending on the profibus dp class. I couldnīt find info about advantages, or why they adopt master-slave...
|
Forum: LIVE PLC Questions And Answers
September 30th, 2010, 01:17 PM
|
Replies: 4
Views: 4,359
master slave advantages?
hey guys! i was wondering why did profibus adopted the master-slave exchange of data? it is the most efficient way?
For example if i had a profibus-dp network with 5 stations (pc + 2 master + 2...
|
Forum: LIVE PLC Questions And Answers
September 27th, 2010, 04:52 PM
|
Replies: 0
Views: 1,201
kepserver
has anyone make a s7-300 via profibus dp connection with kepserver? i read the drivers and it only supports MPI protocol with s7-300. So anyone have find a solution in this case?, other opc server...
|
Forum: LIVE PLC Questions And Answers
September 24th, 2010, 08:48 PM
|
Replies: 0
Views: 1,096
cp5611a2 getting started
Hey guys!
any manual about configuring s7300 and s7200 via cp5611 pci card? Iīm reading the manual and there is no info of step7, and also thereīs no wiring scheme. I only have a profibus cable...
|
Forum: LIVE PLC Questions And Answers
September 24th, 2010, 04:54 PM
|
Replies: 2
Views: 1,446
as-i bus
i was reading about the as-i bus and got stuck with the bus.....it says that the supply and data are share on the same cable. how it works? can anybody explain this please?
thank you all for your...
|
Forum: LIVE PLC Questions And Answers
September 22nd, 2010, 09:31 PM
|
Replies: 8
Views: 2,766
thanks dchartier for your answer, but i would...
thanks dchartier for your answer, but i would like to know how exactly i can get the data of the plc. I mean i need Wincc? can i do it with Lookout
?(i only have access to this software) thanks for...
|
Forum: LIVE PLC Questions And Answers
September 21st, 2010, 11:00 AM
|
Replies: 8
Views: 2,766
thanks maitomies for the answer!, i recently...
thanks maitomies for the answer!, i recently checked a post that specifies all the choices to connect the plc to a pc.
My problem is that i only have access to the software Lookout because the...
|
Forum: LIVE PLC Questions And Answers
September 20th, 2010, 08:50 PM
|
Replies: 8
Views: 2,766
Hmi scada for siemens s7
Iīm doing a profibus network with 1 plc s7-300 and 5 s7-200 for process control. I would like to know wich software suites more to my devices, can i use Lookout(NI) with the siemens plc? or...
|
Forum: LIVE PLC Questions And Answers
September 20th, 2010, 07:11 PM
|
Replies: 6
Views: 3,702
|
Forum: LIVE PLC Questions And Answers
September 20th, 2010, 12:09 PM
|
Replies: 6
Views: 3,702
|
Forum: LIVE PLC Questions And Answers
September 18th, 2010, 03:47 PM
|
Replies: 6
Views: 3,702
Thanks dchartier for the answer, iīm sorry my...
Thanks dchartier for the answer, iīm sorry my english is not good but iīll try to explain my doubt:
I need to configure a profibus dp network master slave communication.
1) CPU 314C-2DP as master ...
|
Forum: LIVE PLC Questions And Answers
September 16th, 2010, 09:34 PM
|
Replies: 6
Views: 3,702
load profibus configuration step7
hey guys! i would like to know how i can load all the profibus configuration between a s7-300 with a s7-200 via EM 277 profibus dp module in step7(the hw configuration is all done). Iīm searching in...
|
Forum: LIVE PLC Questions And Answers
September 16th, 2010, 05:06 PM
|
Replies: 2
Views: 1,891
s7-300 cpu 314c-2dp
Hey guys! i'm knew with programable logic controllers, i am using a s7-300 and i have some doubts.... did someone had experience with this controller? I would like a nicest manual system's because...
|