Search: Posts Made By: Yuryas
Forum: LIVE PLC Questions And Answers June 25th, 2009, 08:59 PM
Replies: 7
Views: 1,413
Posted By Yuryas
Thank you. It is not a question at all what is...

Thank you.
It is not a question at all what is used to "mark in" the flow in the pipes: “the moving dots” or some static symbol..
The question is the automatic transfer of the reliable information...
Forum: LIVE PLC Questions And Answers June 24th, 2009, 12:32 PM
Replies: 7
Views: 1,413
Posted By Yuryas
Thank you, FransisL. It took some time to...

Thank you, FransisL.

It took some time to test the various options with this suspicious for you “moving dots”.
If we assume that our piping operator has to understand at glance:
a) whether a...
Forum: LIVE PLC Questions And Answers May 21st, 2009, 02:12 AM
Replies: 10
Views: 3,120
Posted By Yuryas
diwa130, my idea was simple: In case of...

diwa130,

my idea was simple:
In case of your FB interface and the internal variables structure are not complex,
you could make loop with one working DB and
using WORD_TOBLOCK_DB(myDB).dw[j]...
Forum: LIVE PLC Questions And Answers May 20th, 2009, 07:55 AM
Replies: 10
Views: 3,120
Posted By Yuryas
As for DB I use this way: myDB :WORD; i :INT;...

As for DB I use this way:
myDB :WORD;
i :INT;
j:INT;
...............

// set i, j as you want, then
myDB:=INT_TO_WORD(500+i);

// then Use DB This Way
Forum: LIVE PLC Questions And Answers May 19th, 2009, 06:34 AM
Replies: 17
Views: 22,295
Posted By Yuryas
An Example with Siemens: Simatic PCS 7 ...

An Example with Siemens:

Simatic PCS 7 is DCS
As a rule it is based on Simatic 414 – 416 PLCs.
Forum: LIVE PLC Questions And Answers April 17th, 2009, 03:58 AM
Replies: 14
Views: 4,592
Posted By Yuryas
Do you mean Delphi project must do something? ...

Do you mean Delphi project must do something?
Not just read and write the variables?
Forum: LIVE PLC Questions And Answers April 17th, 2009, 03:26 AM
Replies: 14
Views: 4,592
Posted By Yuryas
Yes, you are right. Mistake! Then an...

Yes, you are right. Mistake!

Then an Example from source:
http://www.automation-drives.ru/as/download/doc/software/runtime/ProdaveMPI_r.doc

// Declarations
function Load_tool ( no :...
Forum: LIVE PLC Questions And Answers April 17th, 2009, 02:39 AM
Replies: 14
Views: 4,592
Posted By Yuryas
This recource...

This recource http://www.opcconnect.com/delphi.php
contains all files needed to make OPCClient with Delphi.
Download at least the first two Zips at the page.
Then run Simatic Scout to see how to...
Forum: LIVE PLC Questions And Answers April 16th, 2009, 09:43 AM
Replies: 1
Views: 1,190
Posted By Yuryas
We use Kepware OPC Server with Intouch for an...

We use Kepware OPC Server with Intouch for an exchange with Simatic 317-2DP.(Scan 1 sec ~1000 items, Ethernet) No problems so far.
Forum: LIVE PLC Questions And Answers April 13th, 2009, 12:07 PM
Replies: 7
Views: 1,413
Posted By Yuryas
FrancisL, Thank you, indeed, for your...

FrancisL,

Thank you, indeed, for your remark.
The difference is:
Compare to universal ControlDraw - component pipingDraw.Net is quite specialized for the pipe transport Animation requirements...
Forum: LIVE PLC Questions And Answers April 12th, 2009, 01:09 AM
Replies: 7
Views: 1,413
Posted By Yuryas
http://www.plctalk.net/qanda/attachment.php?attach...

http://www.plctalk.net/qanda/attachment.php?attachmentid=10152&stc=1&d=1239517467
Forum: LIVE PLC Questions And Answers April 11th, 2009, 09:32 PM
Replies: 7
Views: 1,413
Posted By Yuryas
An idea about pipe transport animation

Gentlemen,

I have an idea that the reliable or at least repeatable results for “pipe animation” could be achieved by creating an piping routes model first and then implementing it in a software...
Forum: LIVE PLC Questions And Answers April 11th, 2009, 08:12 AM
Replies: 28
Views: 3,156
Posted By Yuryas
More flexible and powerful sequencer functions ...

More flexible and powerful sequencer functions
For s7xx – multitasking
Integration of PC & PLC in one box…
Forum: LIVE PLC Questions And Answers April 10th, 2009, 03:57 AM
Replies: 8
Views: 1,188
Posted By Yuryas
Last September Binauras wrote “A common...

Last September Binauras wrote

“A common problem in animating transport pipes is the number of options you have to consider in order to animate the pipes correctly. For instance, a system with 2...
Forum: LIVE PLC Questions And Answers April 10th, 2009, 12:45 AM
Replies: 5
Views: 1,414
Posted By Yuryas
Book I had tested OPC Client for Visual Basic.Net from...

I had tested OPC Client for Visual Basic.Net from
http://www.opcsystems.com/opc_controls_net.htm (http://www.opcsystems.com/opc_controls_net.htm).
The results are good.
The simple examples and an...
Forum: LIVE PLC Questions And Answers March 26th, 2009, 05:54 AM
Replies: 9
Views: 1,208
Posted By Yuryas
"DirectNet OPC Server" supports DL05, DL06. ...

"DirectNet OPC Server" supports DL05, DL06.
Works with OPC Server KEPServerEX (http://www.kepware.com/Products/kepserverex_features.html)
There is a free demo.
Forum: LIVE PLC Questions And Answers March 26th, 2009, 05:29 AM
Replies: 5
Views: 819
Posted By Yuryas
Take a look at SIMATIC S7-mEC: WinXP Embedded ...

Take a look at SIMATIC S7-mEC:
WinXP Embedded
Soft Controller - WinAC (functions of S300 series)
Works with WinCC Flexible too.
You will save on:
OPC,
Lean Ethernet card,
PC system block,...
Forum: LIVE PLC Questions And Answers March 20th, 2009, 03:57 AM
Replies: 2
Views: 3,888
Posted By Yuryas
Basically you should configure: 1. OPC Server -...

Basically you should configure:
1. OPC Server - how to do it - nearest is doc: "How_to_set_up_OPC_with_Simatic_Net.doc". See this site Downloads/Siemens
2. OPC Client for using with VB. There are...
Forum: LIVE PLC Questions And Answers March 20th, 2009, 01:12 AM
Replies: 49
Views: 8,994
Posted By Yuryas
I also agree that 3d piping looks fantastic and...

I also agree that 3d piping looks fantastic and it is very good for the presentation purposes.
But I spent hudreds of hours commissioning the piping Plants with my colleague from our mechanical...
Forum: LIVE PLC Questions And Answers March 19th, 2009, 05:55 AM
Replies: 49
Views: 8,994
Posted By Yuryas
There is an idea which, probably, satisfy both...

There is an idea which, probably, satisfy both points of view.
1. Make Coloring for the filled segments of a pictured pipeline
2. If the pipeline is open from its inlet to the end - show dashed...
Forum: LIVE PLC Questions And Answers March 18th, 2009, 03:54 AM
Replies: 49
Views: 8,994
Posted By Yuryas
We had the same problem some time ago. But now...

We had the same problem some time ago. But now our
approach is to image a piping as a a net of the pipe links,
connected each other. Each link "knows" the state of the adjacent links and...
Showing results 1 to 21 of 21

 