Search: Posts Made By: PLC Pie Guy
Forum: LIVE PLC Questions And Answers Today, 10:39 AM
Replies: 24
Views: 515
Posted By PLC Pie Guy
Sorry... I should have said User Defined Data...

Sorry... I should have said User Defined Data Structures (UDT). You cant create a new one in the standard version.
Forum: LIVE PLC Questions And Answers Today, 09:48 AM
Replies: 24
Views: 515
Posted By PLC Pie Guy
User Defined is available only with the developer...

User Defined is available only with the developer version. You can use a UDFB but not modify or create one in standard version.
Forum: LIVE PLC Questions And Answers Yesterday, 12:07 PM
Replies: 24
Views: 515
Posted By PLC Pie Guy
I love the re tentative data but cant stand the...

I love the re tentative data but cant stand the no Ethernet on the 830. ughhh!

Iv never used one.
Forum: LIVE PLC Questions And Answers Yesterday, 05:32 AM
Replies: 24
Views: 515
Posted By PLC Pie Guy
CCW is not to shabby. The HMI graphics kind of...

CCW is not to shabby.
The HMI graphics kind of bite and the PV800 is over priced. However, it is decent equipment. I use lots of the micros of every flavor.
Go wit the Miro stuff or not, its up...
Forum: LIVE PLC Questions And Answers March 19th, 2019, 05:31 AM
Replies: 19
Views: 3,143
Posted By PLC Pie Guy
Iv sent you what you have asked for in a private...

Iv sent you what you have asked for in a private email.

My email server is currently down but should be up soon and it will automatically send.
Sorry for the delayed response, Iv been out for a...
Forum: LIVE PLC Questions And Answers March 19th, 2019, 04:35 AM
Replies: 4
Views: 431
Posted By PLC Pie Guy
I started out using the face plates and AOI...

I started out using the face plates and AOI provided by Rockwell for the 525 series many years ago. I quickly realized that they were a bit complicated in regards to scaling and displaying the...
Forum: LIVE PLC Questions And Answers March 15th, 2019, 09:43 AM
Replies: 8
Views: 443
Posted By PLC Pie Guy
All good here now!!!

All good here now!!!
Forum: LIVE PLC Questions And Answers March 15th, 2019, 04:22 AM
Replies: 8
Views: 443
Posted By PLC Pie Guy
Still no access.. "This site cant be...

Still no access..

"This site cant be reached" message.


Could be my IT dept. I don't think they like me very much.....
Forum: LIVE PLC Questions And Answers March 14th, 2019, 11:03 AM
Replies: 8
Views: 443
Posted By PLC Pie Guy
ODD. Still not working here Its been...

ODD.
Still not working here

Its been like that for a few hours at least for me.
I haven't tried otherwise for at least a week now.
Forum: LIVE PLC Questions And Answers March 14th, 2019, 10:48 AM
Replies: 8
Views: 443
Posted By PLC Pie Guy
Yup!

Yup!
Forum: LIVE PLC Questions And Answers March 14th, 2019, 10:30 AM
Replies: 17
Views: 1,036
Posted By PLC Pie Guy
Not a trainer kit but a cool little thing if your...

Not a trainer kit but a cool little thing if your bored for a few minutes.

Anybody remember the PLC Fiddle?? www.plcfiddle.com
Forum: LIVE PLC Questions And Answers March 7th, 2019, 07:23 AM
Replies: 10
Views: 433
Posted By PLC Pie Guy
Im curious how you end up with 6 non...

Im curious how you end up with 6 non communicating 5/05.
Iv never had 1 fail, and for a few years, I was neck deep in them. I had some older 5/03 units fail but that is it.
You must be using them...
Forum: LIVE PLC Questions And Answers March 7th, 2019, 04:28 AM
Replies: 4
Views: 400
Posted By PLC Pie Guy
Personally, I go to the RA site and use the...

Personally, I go to the RA site and use the available download called
"UDFB for MICRO 800 Counter Mode 0"

Its the simplest HSC instruction they have. Start, Stop counts, Initial and max values...
Forum: LIVE PLC Questions And Answers March 1st, 2019, 04:39 AM
Replies: 13
Views: 719
Posted By PLC Pie Guy
Indeed it does say TEW on it. Good info with...

Indeed it does say TEW on it.
Good info with the ability to use the wire in both countries. I'm in the beginning phases of building a large cabinet to send to the US now, first time. This one I...
Forum: LIVE PLC Questions And Answers February 19th, 2019, 04:09 PM
Replies: 34
Views: 2,146
Posted By PLC Pie Guy
It is inverter rated. Whats your normal...

It is inverter rated.


Whats your normal /average output current when it is at speed?? Conveyor loaded!

Chances are, if this is happening over several similar applications, then it could be...
Forum: LIVE PLC Questions And Answers February 19th, 2019, 04:01 PM
Replies: 7
Views: 355
Posted By PLC Pie Guy
Feeling this one. I have to put 600 volt...

Feeling this one.
I have to put 600 volt control transformers in mmost of my stuff since MOST of our supply is 600. The fancy little 500 V to 24VDC power supply let the smoke out when they meet the...
Forum: LIVE PLC Questions And Answers February 19th, 2019, 03:49 PM
Replies: 34
Views: 2,146
Posted By PLC Pie Guy
I use the 600VAC supply commonly to run 480...

I use the 600VAC supply commonly to run 480 motors on 600 VAC drives in our plant. Its only an issue if the motors are not good quality. Usually the type I see come in on new ventilation equipment,...
Forum: LIVE PLC Questions And Answers February 19th, 2019, 03:36 PM
Replies: 34
Views: 2,146
Posted By PLC Pie Guy
You can still do an autotune. Select to "Static"...

You can still do an autotune. Select to "Static" tune the motor. It will not turn while tuning.
Forum: LIVE PLC Questions And Answers February 19th, 2019, 12:31 PM
Replies: 34
Views: 2,146
Posted By PLC Pie Guy
You did post them.... opss :o: Quick...

You did post them.... opss :o:

Quick thought.... were you able to successfully autotune the drives with these motors?
Forum: LIVE PLC Questions And Answers February 19th, 2019, 12:30 PM
Replies: 34
Views: 2,146
Posted By PLC Pie Guy
What are you accel and decel times. These...

What are you accel and decel times. These parameters set to low, trying to start and stop a heavy load to quickly will absolutely cause these faults.

As for Ethernet loss..... folks will likely...
Forum: LIVE PLC Questions And Answers February 19th, 2019, 11:48 AM
Replies: 7
Views: 385
Posted By PLC Pie Guy
1 Slot of inputs dedicated to this purpose. ...

1 Slot of inputs dedicated to this purpose.

A plug to connect the two machines with 16 pns in each plug. Each machine would have a jumper to a different pin so a different input would light up...
Forum: LIVE PLC Questions And Answers February 16th, 2019, 10:39 AM
Replies: 13
Views: 719
Posted By PLC Pie Guy
I mean making an extension cord or replacing the...

I mean making an extension cord or replacing the cord on a tool such as an electric drill. This cable commonly gets used for that purpose, and rightfully so as its really great stuff. However, its...
Forum: LIVE PLC Questions And Answers February 16th, 2019, 08:22 AM
Replies: 13
Views: 719
Posted By PLC Pie Guy
I get it through my local wholesaler. Its...

I get it through my local wholesaler.

Its from a company called D.C. Cables LTD. in Quebec.
www.dccables.com


They have all colors and sizes.

As for you 3 Cond, if its leaving the...
Forum: LIVE PLC Questions And Answers February 16th, 2019, 05:38 AM
Replies: 56
Views: 8,042
Posted By PLC Pie Guy
Perhaps they heard me getting angry and decided...

Perhaps they heard me getting angry and decided to fix it then!!
Just a hunch.

I'm glad its back. I'm installing a machine today with a Micro850 brain. I really needed my software.


Now, I'm...
Forum: LIVE PLC Questions And Answers February 16th, 2019, 05:31 AM
Replies: 13
Views: 719
Posted By PLC Pie Guy
My CSA inspector loves us using 105 degree...

My CSA inspector loves us using 105 degree Celsius, Machine Tool Wire. It helps with current rating and duct fill and helps you to meet temperature requirements.

I use it for everything within...