Search: Posts Made By: jeffy
Forum: LIVE PLC Questions And Answers April 4th, 2018, 12:13 AM
Replies: 5
Views: 656
Posted By jeffy
ASF, I mucked around with Excel connecting to the...

ASF, I mucked around with Excel connecting to the SQL db to see the alarms info and it involved a number of steps... I was expecting an export function in the alarmeventlogviewer was available to...
Forum: LIVE PLC Questions And Answers April 3rd, 2018, 06:44 AM
Replies: 5
Views: 656
Posted By jeffy
FactoryTalk View SE V9: Alarm logs export?

Hello,
Iím struggling to find where I can export my historical alarms using the alarm & events log viewer component in my runtime project. I canít see anywhere that allows exporting of the alarm...
Forum: LIVE PLC Questions And Answers February 21st, 2018, 10:56 PM
Replies: 6
Views: 522
Posted By jeffy
Tried that DPI setting crawler009 but nadda......

Tried that DPI setting crawler009 but nadda... the laptop screen is only 1920x1080, not high res and definitely not 4k.
Forum: LIVE PLC Questions And Answers February 21st, 2018, 03:12 AM
Replies: 6
Views: 522
Posted By jeffy
Hi Purrdie, tried all this before but did not...

Hi Purrdie, tried all this before but did not work unfortunately - thanks for responding.
Forum: LIVE PLC Questions And Answers February 21st, 2018, 12:28 AM
Replies: 6
Views: 522
Posted By jeffy
FactoryTalk SE Studio V9 display resolution

Hi,

Got a problem with the FactoryTalk View SE v9 Studio running on one of our laptops. For some reason the studio editor
menus appears truncated and out of scale, therefore the chopped off...
Forum: LIVE PLC Questions And Answers February 20th, 2018, 07:01 AM
Replies: 0
Views: 233
Posted By jeffy
TrendPro parameters in FactoryTalk Studio

Hi,

In FactoryTalk View SE Studio v9, is it possible to pass parameters to the Historical Model field in TrendPro? I can pass parameters to all my tag pens, but the Historical input field doesn't...
Forum: LIVE PLC Questions And Answers December 14th, 2017, 11:46 AM
Replies: 7
Views: 615
Posted By jeffy
On page 127 of the FTV9 SE installation guide...

On page 127 of the FTV9 SE installation guide (appendix F), there is a detailed description of how to rectify this particular problem... this DCOM issue also caused my derived tags and hmi tags to...
Forum: LIVE PLC Questions And Answers December 14th, 2017, 06:04 AM
Replies: 7
Views: 615
Posted By jeffy
Got it all going and working as per normal...

Got it all going and working as per normal phew..., turned out to be a bleedin' window's DCOM related setting screwing things up.

I disagree with you Rdrast, overall FT is working quite nicely...
Forum: LIVE PLC Questions And Answers December 6th, 2017, 10:43 PM
Replies: 7
Views: 615
Posted By jeffy
Hi John, yes i did start the data model as i've...

Hi John, yes i did start the data model as i've described.
Forum: LIVE PLC Questions And Answers December 6th, 2017, 11:28 AM
Replies: 7
Views: 615
Posted By jeffy
hello? has nobody ever had a similar issue?

hello? has nobody ever had a similar issue?
Forum: LIVE PLC Questions And Answers November 30th, 2017, 06:56 AM
Replies: 7
Views: 615
Posted By jeffy
FactoryTalk Studio; no data in the datalog?

Hi there,
I'm running FactoryTalk View Studio V9 on Win 10 Pro (x64) system. I've got a strange problem with the datalogging and wonder if anyone's experienced the same? Any help and input will be...
Forum: LIVE PLC Questions And Answers September 30th, 2012, 12:54 PM
Replies: 1
Views: 1,185
Posted By jeffy
Kepserver with multiple clients?

Hello, I hope someone can answer my query below.

Scenario:
I have a Scada PC operating RSView32 runtime, and Iím using Kepserver as the OPC server.
I have a 2nd Scada PC, on the same network,...
Forum: LIVE PLC Questions And Answers September 24th, 2012, 11:22 PM
Replies: 4
Views: 2,517
Posted By jeffy
Thanks for the input guys. The project could well...

Thanks for the input guys. The project could well have been created before v6.00 so that may explain it.

Yes the .gfx file turns out completely blank.

I've just resorted to the alternative...
Forum: LIVE PLC Questions And Answers September 24th, 2012, 06:42 AM
Replies: 4
Views: 2,517
Posted By jeffy
rsview32 works: graphic import/export issue

Hi,

(RSView32 Works v7.50)

I have a problem with exporting and importing of graphic files between projects.
I export graphics from one project and then import them into a different project. ...
Forum: LIVE PLC Questions And Answers September 24th, 2012, 03:00 AM
Replies: 4
Views: 1,623
Posted By jeffy
Hi TConnelly, I've been using the parameter...

Hi TConnelly,

I've been using the parameter files and has been working well with replicating whole Graphic display pages. (Thanks for your previous explanation!)

However, I now have a...
Forum: LIVE PLC Questions And Answers September 11th, 2012, 11:41 PM
Replies: 4
Views: 1,623
Posted By jeffy
Thanks TConnelly for your reply, much...

Thanks TConnelly for your reply, much appreciated. That'll be most useful so i'll start using that! :dance:
Forum: LIVE PLC Questions And Answers September 11th, 2012, 07:29 AM
Replies: 4
Views: 1,623
Posted By jeffy
RSView32 Works graphics

Hi all,

Is RSView32 Works capable of producing smart graphics, similar to that of faceplates or CitectScada's Genies & supergenies? Thank you in advance for your input.

(I couldn't find any...
Forum: LIVE PLC Questions And Answers August 7th, 2012, 05:12 AM
Replies: 2
Views: 2,535
Posted By jeffy
Kepserver v5.3 --> v4.5

Hi everyone,

Regarding Kepserver; when i open up a project file (.pfe format) that was edited in Kepserver v5.3; i am unable to load the same file in Kepserver v4.5.

What is the best way for me...
Forum: LIVE PLC Questions And Answers August 5th, 2012, 06:51 AM
Replies: 2
Views: 3,002
Posted By jeffy
CP341 to Kepware OPC : Modbus TCP

Hi Modbus experts,

I am currently experiencing ModbusTCP communications trouble.
I want to read Modbus addressed data from a Siemens S7-300 via its CP341 card into my Kepserver OPC using...
Forum: LIVE PLC Questions And Answers July 30th, 2012, 11:42 PM
Replies: 3
Views: 1,610
Posted By jeffy
Thanks Ethan & Gil for your responses. I followed...

Thanks Ethan & Gil for your responses. I followed Ethans suggestion and it has answered my query! Thanks fellas!
Forum: LIVE PLC Questions And Answers July 11th, 2012, 02:20 AM
Replies: 3
Views: 1,610
Posted By jeffy
RSview & Kepware tag databases

Hi,

I am using RSView32 works and Kepware as the OPC.
I find it frustrating that whenever i need to add new IO to the scada system, I have to edit tag databases for BOTH the RSview & Kepware...
Forum: LIVE PLC Questions And Answers June 9th, 2012, 11:54 PM
Replies: 4
Views: 1,857
Posted By jeffy
Hi Jamesrustin, Referring to the 'memory...

Hi Jamesrustin,

Referring to the 'memory view' of CPU67, the 'E' memory area stretches from E0 to EE, whereas CPU66 has a smaller 'E' memory range (E0 to E9 only).

My fix was to simply shift...
Forum: LIVE PLC Questions And Answers June 6th, 2012, 12:39 AM
Replies: 2
Views: 1,285
Posted By jeffy
Thanks for another response Lostcontrol. I have...

Thanks for another response Lostcontrol. I have noted in my previous post that this issue has now been resolved.

The 66 and 67 memory areas a different, so basically it was just a case of...
Forum: LIVE PLC Questions And Answers June 6th, 2012, 12:37 AM
Replies: 4
Views: 1,857
Posted By jeffy
Thanks lostcontrol for your response, I've...

Thanks lostcontrol for your response, I've resolved the issue now.
Yes there are plenty of FBs used.
What I did was to relocate the FBs to a different memory area and address.
Voila - fixed! ...
Forum: LIVE PLC Questions And Answers June 6th, 2012, 12:33 AM
Replies: 1
Views: 1,709
Posted By jeffy
omron cj1w-etn21 version change

Hi,

I'm having difficulty configuring the ethernet card on on our Omron CJ2H-CPU66 rack.

Using the PLC IO table to configure the ethernet card, CX-Progr will not verify the target ethernet...