Search: Posts Made By: Vince30
Forum: LIVE PLC Questions And Answers February 7th, 2017, 08:08 AM
Replies: 6
Views: 744
Posted By Vince30
Oh I get it now. I've never used connected...

Oh I get it now. I've never used connected components, but in AB FactoryTalk Studio there is a tab in the explorer window under System called Global Connections. That is where you assign a tag for...
Forum: LIVE PLC Questions And Answers February 6th, 2017, 12:09 PM
Replies: 6
Views: 744
Posted By Vince30
I'm not sure I understand what you're trying to...

I'm not sure I understand what you're trying to accomplish. I played with it a little to just make a conditional out based on day and time and I found the hour minute thing to be a little tricky, so...
Forum: LIVE PLC Questions And Answers February 6th, 2017, 11:08 AM
Replies: 23
Views: 2,466
Posted By Vince30
Ah, okay. Thanks for the advice, I will use that...

Ah, okay. Thanks for the advice, I will use that from now on.
Forum: LIVE PLC Questions And Answers February 6th, 2017, 09:57 AM
Replies: 23
Views: 2,466
Posted By Vince30
I've used them in situations where I have working...

I've used them in situations where I have working code, but am trying to change the way it does a section of the sub. I'll throw an MCR in to ignore the original code without messing with it. But I...
Forum: LIVE PLC Questions And Answers February 6th, 2017, 09:50 AM
Replies: 6
Views: 744
Posted By Vince30
AB Panelview HMIs have clocks in them which the...

AB Panelview HMIs have clocks in them which the PLC can read. They are more reliable than setting timers in the PLC, and would be very simple to accomplish.
Forum: LIVE PLC Questions And Answers November 3rd, 2016, 12:09 AM
Replies: 7
Views: 1,141
Posted By Vince30
That was such a roller coaster of emotions. Great...

That was such a roller coaster of emotions. Great game.
Forum: LIVE PLC Questions And Answers November 2nd, 2016, 02:05 PM
Replies: 14
Views: 5,865
Posted By Vince30
We'd hate to keep OP waiting

We'd hate to keep OP waiting
Forum: LIVE PLC Questions And Answers November 2nd, 2016, 08:31 AM
Replies: 7
Views: 1,141
Posted By Vince30
Go Cubs! The attitude around here has been...

Go Cubs! The attitude around here has been unreal, it will be nuts if they win tonight. But looking at the pitching lineup, I am not expecting a win.
Forum: LIVE PLC Questions And Answers November 1st, 2016, 04:33 PM
Replies: 13
Views: 2,368
Posted By Vince30
You can bump the timer preset down to 14 and...

You can bump the timer preset down to 14 and write a move instruction to put a value of 5 to T4:3.ACC triggered by an XIC from T4:3.DN
Forum: LIVE PLC Questions And Answers November 1st, 2016, 03:16 PM
Replies: 13
Views: 2,368
Posted By Vince30
One thing I notice with your vibrator section is...

One thing I notice with your vibrator section is you have a TOF being triggered by the start delay's DN signal. The TOF instruction doesn't begin counting until it sees a true-to-false transition. I...
Forum: LIVE PLC Questions And Answers November 1st, 2016, 01:00 PM
Replies: 13
Views: 2,368
Posted By Vince30
I took dwoodlock's advice and simplified what I...

I took dwoodlock's advice and simplified what I previously posted using limits reading one timer instead of a chain of timers.

http://i.imgur.com/2ucaHxG.jpg
Forum: LIVE PLC Questions And Answers November 1st, 2016, 11:52 AM
Replies: 13
Views: 2,368
Posted By Vince30
This isn't for a school project is it? I don't...

This isn't for a school project is it? I don't want to give away answers.

This is what I've come up with given what I got out of your first post.

http://i.imgur.com/rlgU44g.jpg
Forum: LIVE PLC Questions And Answers October 31st, 2016, 12:04 PM
Replies: 19
Views: 2,824
Posted By Vince30
If you make a tag like Record and set it as...

If you make a tag like Record and set it as DINT[900] it will expand as Record[0] - Record[900]. The numeric in the tag can be set as an address such as a counter. So you can make a timer counter or...
Forum: LIVE PLC Questions And Answers October 28th, 2016, 04:32 PM
Replies: 30
Views: 93,588
Posted By Vince30
Fairly new programmer, just joined the forums,...

Fairly new programmer, just joined the forums, and now saw this so created a linkedin account. Guess I might as well go all in with surrounding myself with knowledgeable people.
Forum: LIVE PLC Questions And Answers October 28th, 2016, 04:08 PM
Replies: 19
Views: 2,824
Posted By Vince30
I just responded to your other post. But if you...

I just responded to your other post. But if you missed it
Showing results 1 to 15 of 15

 