Search: Posts Made By: blima
Forum: LIVE PLC Questions And Answers July 19th, 2018, 10:45 AM
Replies: 6
Views: 620
Posted By blima
Thanks for the replys! I'm going to look at it.

Thanks for the replys! I'm going to look at it.
Forum: LIVE PLC Questions And Answers July 17th, 2018, 08:57 AM
Replies: 6
Views: 620
Posted By blima
Solutions in servomotors for printing industry

Hello!

In the next year, my company is going to change a printing machine, that uses a single DC motor with a long shaft, for several servomotors in a shaftless solution.

At this point I can...
Forum: LIVE PLC Questions And Answers March 15th, 2018, 09:59 AM
Replies: 1
Views: 356
Posted By blima
S7-200 to S7-1200 with V10.5 Basic

Hello,

I have searched the website, from Siemens, but could not find a working link to the conversion tool from S7-200 to S7-1200. To install in TIA Portal Basic 10.5.

Can anyone please provide...
Forum: LIVE PLC Questions And Answers June 28th, 2017, 08:31 AM
Replies: 10
Views: 626
Posted By blima
Great tip! Thanks

Great tip! Thanks
Forum: LIVE PLC Questions And Answers June 27th, 2017, 10:55 AM
Replies: 4
Views: 728
Posted By blima
Thanks for all the inputs, but this one was very...

Thanks for all the inputs, but this one was very good.

I have finished the upgrade and in fact is quite odd for me that in this old PLC the outputs are similar to the inputs! I had to use tags to...
Forum: LIVE PLC Questions And Answers June 22nd, 2017, 04:38 PM
Replies: 4
Views: 728
Posted By blima
Converting Omron c28k program to cp1e

Hello!

I'm working in upgrading an old c28k Omron to a cp1e.

My doubts are concerning the IO pins. I can see in syswin 3.4 the following inputs:
0.0 to 0.15 so I should convert it to 0.0 to...
Forum: LIVE PLC Questions And Answers June 6th, 2017, 09:37 AM
Replies: 6
Views: 758
Posted By blima
Thanks for the inputs! I have to work on the...

Thanks for the inputs!

I have to work on the safe side since my compnay it is only me! I can not afford paying breaking down a machine!

Just wanted to know if technicians swap electronic...
Forum: LIVE PLC Questions And Answers June 2nd, 2017, 04:47 PM
Replies: 6
Views: 758
Posted By blima
Testing electronic boards

I have situations in which I doubt if an electronic board is good on an industrial machine. Sometimes I have the possibility to test it on another machine, which is working well, to see if it's her's...
Forum: LIVE PLC Questions And Answers May 16th, 2017, 10:44 AM
Replies: 6
Views: 655
Posted By blima
Thanks for the quick reply. I will request a new...

Thanks for the quick reply. I will request a new board. Will I lose my parameters of the drive?
Forum: LIVE PLC Questions And Answers May 16th, 2017, 09:53 AM
Replies: 6
Views: 655
Posted By blima
F10 on a Reliance Electric drive

Hello!

I have a Reliance Eletric GV3000EAC106-AARFI AC drive with fault N.10 on the display, but on the manual it does not says what it is.

Can anyone indicate me what is the reason for this...
Forum: LIVE PLC Questions And Answers February 10th, 2017, 12:03 PM
Replies: 7
Views: 1,079
Posted By blima
Hmm, I'm a little confused now! lol Looking...

Hmm, I'm a little confused now! lol

Looking at the table on the last link, I can see some system bits for serial communication on RS232. Correct? Or this are the bits that I have to use also for...
Forum: LIVE PLC Questions And Answers February 10th, 2017, 09:51 AM
Replies: 7
Views: 1,079
Posted By blima
Another thing that perhaps could make the...

Another thing that perhaps could make the diference is that this optional board is connected on the right port of the CP1E PLC. The system bits for starting RS485 are still the same?
Forum: LIVE PLC Questions And Answers February 10th, 2017, 09:47 AM
Replies: 7
Views: 1,079
Posted By blima
Hello Gclshortt! I have already gone throw...

Hello Gclshortt!

I have already gone throw the examples that you have pointed out on your link but still no sucess!

I have hardwire the omron cp1w-cif11 in the following way:
All dip switchs...
Forum: LIVE PLC Questions And Answers February 10th, 2017, 06:03 AM
Replies: 7
Views: 1,079
Posted By blima
Modbus form Omron CP1E and a Danfoss drive

Hello!

I have tried to communicate with a Danfoss drive Aqua FC301 over RS485 but I had no sucess!

Attached you will find the demo project that I'm using. I want to read the register 2910 wich...
Forum: LIVE PLC Questions And Answers September 8th, 2016, 10:02 AM
Replies: 16
Views: 1,448
Posted By blima
Hi! I have used the following way to move...

Hi!

I have used the following way to move data between databases.
Forum: LIVE PLC Questions And Answers September 6th, 2016, 10:32 AM
Replies: 3
Views: 2,634
Posted By blima
Thanks!

Thanks!
Forum: LIVE PLC Questions And Answers April 13th, 2016, 04:04 PM
Replies: 2
Views: 554
Posted By blima
thanks for the input! I think I will make a list...

thanks for the input! I think I will make a list of the hardware that I have on site and after studying it, I will contact the manufacturer!

Thanks,
Bruno
Forum: LIVE PLC Questions And Answers April 13th, 2016, 03:09 PM
Replies: 2
Views: 554
Posted By blima
Where to start with PILZ

Hello!

I came accross some PLC's from PILZ in cable cars. I'm very confortable with Siemens STL and SCL, but I'm zero with PILZ. I'm think learning the basics of PILZ, so I can troubleshoot this...
Forum: LIVE PLC Questions And Answers July 29th, 2015, 02:55 PM
Replies: 0
Views: 803
Posted By blima
Learn Simotion

Hello,

In my company we are considering if it is possible to adapt servomotors from Siemens in our machines. I have TIA Scout v4.4 on a laptop but I do not have courses on this software.

Where...
Forum: LIVE PLC Questions And Answers May 4th, 2015, 08:14 AM
Replies: 5
Views: 3,080
Posted By blima
Thanks L D for the examples!

Thanks L D for the examples!
Forum: LIVE PLC Questions And Answers February 3rd, 2015, 05:58 AM
Replies: 2
Views: 743
Posted By blima
3 pumps and 1 flowmeter

Hello!

I have a project with 3 water pumps, controlled by ABB ACS500 drives, and only 1 flowmeter at the exit of the pipeline, that is commom to all. Normally I will work only with one pump, but I...
Forum: LIVE PLC Questions And Answers January 15th, 2015, 08:22 AM
Replies: 0
Views: 869
Posted By blima
ACS550 ABB Drive in TIA

Hello!

In the attached photo you will see my ABB Drive in my device configuration tool in TIA v12. It will be controlled by PROFIBUS.

I think that Failsafe PZD1 word is in fact the control word...
Forum: LIVE PLC Questions And Answers January 14th, 2015, 09:03 AM
Replies: 1
Views: 1,233
Posted By blima
Found the solution for this problem: ...

Found the solution for this problem:
https://www.automation.siemens.com/WW/forum/guests/PostShow.aspx?PageIndex=1&PostID=606220&Language=en#606220
Forum: LIVE PLC Questions And Answers January 14th, 2015, 07:47 AM
Replies: 1
Views: 1,233
Posted By blima
Trying to install ABB Drive function FB500 in TIA v12

Hello,

I have a application where I have 3 drives ABB ACS500 to control by a S7-300 CPU. I have tried to import the FB500 but I can not find it in TIA v12. How can I import this FB?

I have...
Forum: LIVE PLC Questions And Answers January 3rd, 2015, 04:06 PM
Replies: 2
Views: 1,035
Posted By blima
Ok. Thanks! I will try it with Windows XP on...

Ok. Thanks!

I will try it with Windows XP on parallel desktop to see if it works for me.

Thanks.
Showing results 1 to 25 of 85

 