You are not registered yet. Please click here to register!


 
 
plc storereviewsdownloads
This board is for PLC Related Q&A ONLY. Please DON'T use it for advertising, etc.
 
Try our online PLC Simulator- FREE.  Click here now to try it.

---------->>>>>Get FREE PLC Programming Tips

New Here? Please read this important info!!!


Go Back   PLCS.net - Interactive Q & A > Search Forums

Showing results 1 to 25 of 48
Search took 0.03 seconds.
Search: Posts Made By: dhuber
Forum: LIVE PLC Questions And Answers May 27th, 2014, 09:30 AM
Replies: 1
Views: 749
Posted By dhuber
1734-arm

Hi everyone,

I have a AENT-R that I need to change the I/O structure around in due to customer changes in the cell. Instead of re-labeling all of the wires when we remove a few cards, we are...
Forum: LIVE PLC Questions And Answers March 14th, 2014, 10:59 AM
Replies: 7
Views: 1,042
Posted By dhuber
IB8S Equivalent Input Discrepancy

I have a Keyence light curtain, SL-V32HM that is wired to an IB8S in an AENTR. I have the discrepancy time in the IB8S set at 100 ms. The response time for the light curtain is from ON-OFF is 10.3...
Forum: LIVE PLC Questions And Answers January 9th, 2014, 12:59 PM
Replies: 1
Views: 3,540
Posted By dhuber
RSlogix 5000, Cant Upload Or Download.

Hello Everyone,

I have a 1756-L73S with the safety partner in a rack with a 1756-EN2T. This morning when going online with the processor, I was able to go online, but as soon as I clicked save...
Forum: LIVE PLC Questions And Answers August 14th, 2013, 09:27 AM
Replies: 1
Views: 3,446
Posted By dhuber
1734-aentr

Hello Everyone,

I have a 1734 AENTR connected to a 1756-ENBT ethernet card. The AENTR has 10 safety I/O modules and then 2 discrete I/O modules. I am getting an error on the safety modules that...
Forum: LIVE PLC Questions And Answers February 13th, 2013, 11:18 AM
Replies: 14
Views: 4,670
Posted By dhuber
Compactlogix L32E Loss of Date

I have a customer that has asked me why when power is cycled to his Compactlogix he loses the date and time and he has to go back in and set it again.
Battery status light looks good and there is no...
Forum: LIVE PLC Questions And Answers December 18th, 2012, 05:13 PM
Replies: 3
Views: 1,860
Posted By dhuber
1734 ib8s

Hi Everyone.

I have a 1734 IB8S point I/O slice in an 1734-Aentr rack. I have configured the ip address, can see other non safety I/O slices in the rack, and in RSLinx i can see the safety I/O as...
Forum: LIVE PLC Questions And Answers December 17th, 2012, 10:25 AM
Replies: 0
Views: 1,001
Posted By dhuber
SoMachine Software

Hi Everyone,

I have a License and disk for SoMachine and am looking to sell it. The disk has never been opened and the license has never been put on a computer.
If anyone is interested or...
Forum: LIVE PLC Questions And Answers July 12th, 2012, 12:27 PM
Replies: 4
Views: 799
Posted By dhuber
Analog Readings in contrologix

Hi everyone.

I have a question about analog devices and the value that the Plc reads. Do all vain slog devices give the Plc a reading between 0-30800, that's the raw signal and then I do the...
Forum: LIVE PLC Questions And Answers July 5th, 2012, 02:38 PM
Replies: 9
Views: 2,022
Posted By dhuber
When switch A is turned on it scans the...

When switch A is turned on it scans the subroutine and writes a 1 to "B".
When switch A is turned off, it does not scan the subroutine, it doesnt write any value to "B", even though "B" in your...
Forum: LIVE PLC Questions And Answers July 5th, 2012, 02:28 PM
Replies: 1
Views: 1,457
Posted By dhuber
FactoryTalk View Studio Passwords

Hi,

I am wondering if there is a way to change passwords on user accounts during runtime.
I can add a change password button and it allows me to change the password of the User i am logged in...
Forum: LIVE PLC Questions And Answers March 23rd, 2012, 03:52 PM
Replies: 3
Views: 2,501
Posted By dhuber
Ken, Thanks for the response. I did figure...

Ken,

Thanks for the response.
I did figure shortly after posting this question. It was the wiring. I didn't have pin 16 an 18 jumped with pin 11. Once i did that it worked.

Thanks,
Dennis
Forum: LIVE PLC Questions And Answers March 21st, 2012, 09:56 AM
Replies: 3
Views: 2,501
Posted By dhuber
I also don't have the "ready" signal coming back...

I also don't have the "ready" signal coming back from the drive either.

Thanks.
Forum: LIVE PLC Questions And Answers March 21st, 2012, 09:50 AM
Replies: 3
Views: 2,501
Posted By dhuber
AB 150 SMC Flex

Hi All,

I have an Allen Bradley 150 SMC Flex that I need some help with.
I have it set up with a 20-COMM-E card over ethernet back to my control logix PLC.
I get my Enabled bit for Control...
Forum: LIVE PLC Questions And Answers March 2nd, 2012, 02:16 PM
Replies: 10
Views: 2,177
Posted By dhuber
Firmware revision of Controllogix processor is...

Firmware revision of Controllogix processor is 17.1.
And yes i do have the topic defined in the device groups tab.
Forum: LIVE PLC Questions And Answers March 2nd, 2012, 01:35 PM
Replies: 10
Views: 2,177
Posted By dhuber
Here is a screen shot of the SMC.

Here is a screen shot of the SMC.
Forum: LIVE PLC Questions And Answers March 2nd, 2012, 01:21 PM
Replies: 10
Views: 2,177
Posted By dhuber
Another thing, i used wwClient and setup my...

Another thing, i used wwClient and setup my communications in there and was able to see the values of a bit and an integer in my plc change. So it looks like it is communicating, but when i put the...
Forum: LIVE PLC Questions And Answers March 2nd, 2012, 11:40 AM
Replies: 10
Views: 2,177
Posted By dhuber
Looking at the Log Viewer, some faults that i am...

Looking at the Log Viewer, some faults that i am getting that maybe shouldnt be there.

SuiteLink Stream communication failure receiving from ComputerName view: Connection for DASABCIP from...
Forum: LIVE PLC Questions And Answers March 2nd, 2012, 10:24 AM
Replies: 10
Views: 2,177
Posted By dhuber
Wonderware comm with Contrologix

Hi,

I have a wonderware system version 10.1 connecting to a control logix plc. I had communications established and i was able to communicate back and forth while in runtime mode, no problem at...
Forum: LIVE PLC Questions And Answers January 16th, 2012, 09:51 AM
Replies: 7
Views: 3,093
Posted By dhuber
Breaking down an INT to send to a robot

Hi everyone.

I'm working with a Motoman robot and I have to send values ranging from 50-2500 to the robot.
The robot can only accept signed single integers so that only gives me 127. I need to...
Forum: LIVE PLC Questions And Answers January 5th, 2012, 04:23 PM
Replies: 15
Views: 13,190
Posted By dhuber
Hello all, I figured since i figured out...

Hello all,

I figured since i figured out what i had to do to fix the problem and tech support knew exactly what to do to fix it, i would post it on here so if anyone else has the same issue.
...
Forum: LIVE PLC Questions And Answers January 2nd, 2012, 03:51 PM
Replies: 15
Views: 13,190
Posted By dhuber
Factory Talk

Hi All,

I go to open Factory Talk View Studio and I get this error:

"Failed to restore the archived version of the FactoryTalk System Directory. See help or your System Administrator to...
Forum: LIVE PLC Questions And Answers December 15th, 2011, 12:08 PM
Replies: 1
Views: 1,001
Posted By dhuber
1769-ASCII Card

Hi Everyone,

I have a 1769-ASCII card that i am hooking up 2 bar code scanners too. I have a third one hooked up to the RS232 port on the PLC and have that reading in data fine.
I am...
Forum: LIVE PLC Questions And Answers November 15th, 2011, 03:11 PM
Replies: 6
Views: 1,514
Posted By dhuber
I am reupdating the firmware via serial right...

I am reupdating the firmware via serial right now, so hopefully there wont be any problems with it after that.
I was just curious if it did cause any problems even if you did update it through the...
Forum: LIVE PLC Questions And Answers November 15th, 2011, 02:47 PM
Replies: 6
Views: 1,514
Posted By dhuber
Compact Logix Firmware Upgrade

I was upgrading the firmware on a L23E PLC, i set the IP address through Bootp and then started the firmware update, forgetting to disable bootp and when the first power cycle happened the ip address...
Forum: LIVE PLC Questions And Answers August 18th, 2011, 02:24 PM
Replies: 1
Views: 1,051
Posted By dhuber
Compact Logix Upload

Hi,

I want to upload a program from a compact logix, i do not have the original file. Is there a way to upload it without having to select a file to upload?
Everytime i go to upload it says i...
Showing results 1 to 25 of 48

 
Forum Jump

All times are GMT -5. The time now is 07:53 PM.


.