Search: Posts Made By: PreLC
Forum: LIVE PLC Questions And Answers Yesterday, 01:21 PM
Replies: 7
Views: 221
Posted By PreLC
Try to grab a really old copy of chrome from...

Try to grab a really old copy of chrome from ~2010. Load it up on your PC if you can, otherwise on a VM. This should be able to run flash...
Forum: LIVE PLC Questions And Answers April 9th, 2021, 09:21 AM
Replies: 6
Views: 672
Posted By PreLC
If you go to Studio5k V33's "Additional...

If you go to Studio5k V33's "Additional downloads" section(This shows up when selecting what all to download) you can download an image with all V20-33 Logix pre-installed for free, given you own...
Forum: LIVE PLC Questions And Answers April 8th, 2021, 03:53 PM
Replies: 9
Views: 346
Posted By PreLC
Are you sure it doesn't just pull up a...

Are you sure it doesn't just pull up a gateway/pro license from the server? I'm not ab100% if it's free.
Forum: LIVE PLC Questions And Answers April 8th, 2021, 09:30 AM
Replies: 3
Views: 247
Posted By PreLC
From this catalog:...

From this catalog: https://www.staubli.com/en/file/7985.show

Unless you have the CS9/CS9MP, seems like you would also have to purchase the particular option for Ethernet I/P. Apart from that, what...
Forum: LIVE PLC Questions And Answers April 8th, 2021, 09:26 AM
Replies: 9
Views: 346
Posted By PreLC
You can also straight up copy WALLCLOCK into the...

You can also straight up copy WALLCLOCK into the new LINT datatype. This let's you use a combination of MVM and LIM instructions with start and end times as triggers.
Forum: LIVE PLC Questions And Answers April 8th, 2021, 12:50 AM
Replies: 2
Views: 232
Posted By PreLC
It should work, do you have the PF525 add-on...

It should work, do you have the PF525 add-on profile from AB, Try that?

Studio crashes are usually not license linked, and happen due to installation/compatibility issues.
Forum: LIVE PLC Questions And Answers April 3rd, 2021, 07:05 PM
Replies: 8
Views: 466
Posted By PreLC
From my CS1.6 days, I can also recommend this...

From my CS1.6 days, I can also recommend this...
Forum: LIVE PLC Questions And Answers April 3rd, 2021, 06:35 PM
Replies: 11
Views: 416
Posted By PreLC
My acceleration/deceleration is 100mm/s^2, speeds...

My acceleration/deceleration is 100mm/s^2, speeds in 1mm/s. I need to be within 0.1mm precision, so s=ut+1/2at^2, I need to have a reaction time of 0.035825756949558 seconds, using 10x to keep...
Forum: LIVE PLC Questions And Answers April 3rd, 2021, 05:17 PM
Replies: 11
Views: 416
Posted By PreLC
Hi nOrM, I think I have all those answers: ...

Hi nOrM,

I think I have all those answers:


Linear/Rotary (although you have already specified linear)
-Linear
Maximum travel
-1800mm
Required resolution (I believe you said +/-0.1mm)
Forum: LIVE PLC Questions And Answers April 3rd, 2021, 04:33 PM
Replies: 11
Views: 416
Posted By PreLC
Hmm. I was looking at the manual, and the sensor...

Hmm. I was looking at the manual, and the sensor resolution was 1...65535. For the heidenhain, the accuracies are represented in um. Is there a way to find out if they are compatible? I've never...
Forum: LIVE PLC Questions And Answers April 3rd, 2021, 01:19 PM
Replies: 11
Views: 416
Posted By PreLC
Contactless linear encoder for 5069 CompactLogix PLCs?

Hello PLCs.net!

I have a sliding table controlled by a servo. The coupling on this servo is not reliable and we need to reteach the positions the table stops on really often. This is currently...
Forum: LIVE PLC Questions And Answers April 3rd, 2021, 01:07 PM
Replies: 8
Views: 466
Posted By PreLC
If both of your PCs are on the same network, you...

If both of your PCs are on the same network, you can also make one a license server for the other PC and checkout licenses for extended length of times. What's your use case? Do you have two people...
Forum: LIVE PLC Questions And Answers April 2nd, 2021, 03:14 PM
Replies: 10
Views: 718
Posted By PreLC
Maybe you can repurpose something like this:...

Maybe you can repurpose something like this: https://robot-reels.com/

We use them in my plant for teach pendants as intended, but it shouldn't be too hard to strip ends and make custom connectors?
Forum: LIVE PLC Questions And Answers April 1st, 2021, 11:22 AM
Replies: 6
Views: 412
Posted By PreLC
Is this happening for you on all your PCs? What...

Is this happening for you on all your PCs? What was the order of install for the Studio5k software?

When importing, is the task manager reporting a consistent CPU usage? If the task manager can't...
Forum: LIVE PLC Questions And Answers March 31st, 2021, 08:23 PM
Replies: 4
Views: 373
Posted By PreLC
Can you try saving an archive(APA) and restoring...

Can you try saving an archive(APA) and restoring it?
Forum: LIVE PLC Questions And Answers March 31st, 2021, 07:05 PM
Replies: 2
Views: 190
Posted By PreLC
Balluff does have an EDS option, but the generic...

Balluff does have an EDS option, but the generic device option works also.

Could you give us a picture of the device configuration screen? Just to get a picture would be nicer.

Also, what are...
Forum: LIVE PLC Questions And Answers March 31st, 2021, 09:30 AM
Replies: 7
Views: 433
Posted By PreLC
Answer QA15355 ...

Answer QA15355 (https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/508697/loc/en_US#__highlight)talks about this in the RA Knowledgebase. It's not language as in English, German,...
Forum: LIVE PLC Questions And Answers March 28th, 2021, 10:39 AM
Replies: 17
Views: 1,087
Posted By PreLC
Made some ladder, this should work too, in one...

Made some ladder, this should work too, in one rung:
https://i.imgur.com/5eI8QxM.png

Works for 32 bits, but I'm sure for longer boolean arrays we can write an AND and SUB AOI which can handle...
Forum: LIVE PLC Questions And Answers March 27th, 2021, 10:41 AM
Replies: 0
Views: 205
Posted By PreLC
Siemens S7 15.1 fw level backups using AssetCentre?

Hello PLCs.net!

Does anyone know how to configure S7 automated backups for S7 PLCs V15.1?

I am having trouble setting up the ConfigurationFile property in AssetCentre. When I added the project...
Forum: LIVE PLC Questions And Answers March 26th, 2021, 01:45 PM
Replies: 11
Views: 731
Posted By PreLC
What happens if you change localhost to LAPTOP?

What happens if you change localhost to LAPTOP?
Forum: LIVE PLC Questions And Answers March 26th, 2021, 01:38 PM
Replies: 14
Views: 478
Posted By PreLC
Oh no, I'm not implying that the install was a...

Oh no, I'm not implying that the install was a failure mode for you. Should have marked that off topic.
Forum: LIVE PLC Questions And Answers March 26th, 2021, 12:40 PM
Replies: 14
Views: 478
Posted By PreLC
No recurring problems with running any programs...

No recurring problems with running any programs RSLogix5k 13-20 and LogixDesignerV21-33 on windows 10. Development was limited to V20+

Just need to install in the right order with the right...
Forum: LIVE PLC Questions And Answers March 26th, 2021, 10:18 AM
Replies: 14
Views: 478
Posted By PreLC
Check on your PC what the "Specify Factorytalk...

Check on your PC what the "Specify Factorytalk Directory Location" application reports your current directory to be. Then, can you try going to the security tab of the controller properties, and see...
Forum: LIVE PLC Questions And Answers March 26th, 2021, 02:38 AM
Replies: 11
Views: 731
Posted By PreLC
Is your FTServices platform up to date? Older...

Is your FTServices platform up to date? Older versions didn't have support Linx.
Forum: LIVE PLC Questions And Answers March 22nd, 2021, 11:18 AM
Replies: 28
Views: 1,829
Posted By PreLC
Book At my previous plant, our old man controls...

At my previous plant, our old man controls engineer stuck to V20 for PLCs for close to a decade and, just because he didn't want to switch from the EVMove style licensing to the FTActivationManager...
Showing results 1 to 25 of 331

 