Search: Posts Made By: goghie
Forum: LIVE PLC Questions And Answers Yesterday, 06:19 PM
Replies: 24
Views: 3,799
Posted By goghie
We use this quite often, and it is excellent...

We use this quite often, and it is excellent solution, as you do not need to brake during process just at the end of process in order to stop at precise position. We use it with classical U/f drive...
Forum: LIVE PLC Questions And Answers March 16th, 2019, 12:39 PM
Replies: 3
Views: 234
Posted By goghie
Thank you for your info. I see now that it is...

Thank you for your info. I see now that it is Codesys, strange that there is no "SOURCE.DAT".
Forum: LIVE PLC Questions And Answers March 15th, 2019, 04:06 PM
Replies: 3
Views: 234
Posted By goghie
ABB PM581 printout needed

Hi!

I have source code one disc from one machine with ABB PM581 PLC, and I don't have software and I don't know which one should be used.
Would anybody be kind enough to make printout - I will...
Forum: LIVE PLC Questions And Answers December 7th, 2018, 11:08 AM
Replies: 15
Views: 993
Posted By goghie
It Is China copy of Schneider Electric....

It Is China copy of Schneider Electric. Practically identical by dimensions. They sell them as OEM under different brands, and different quality. Mostly are low quality, but you can find also very...
Forum: LIVE PLC Questions And Answers November 22nd, 2018, 04:41 PM
Replies: 25
Views: 943
Posted By goghie
Call programmer and pay him. Even if you crack...

Call programmer and pay him. Even if you crack the password you will obtain program in instruction list without comments and all in one routine... This will be very hard to troubleshoot...
Forum: LIVE PLC Questions And Answers November 21st, 2018, 11:53 AM
Replies: 12
Views: 426
Posted By goghie
Just to mention. Call them and ask them to send...

Just to mention. Call them and ask them to send you "300776invuc.wpa" parametar file (should be in "N:\Dornier_UC\" folder).
In this moment you will need to adjust step relays and latches in order...
Forum: LIVE PLC Questions And Answers November 21st, 2018, 11:45 AM
Replies: 12
Views: 426
Posted By goghie
Here you go. It is GX IEC Developer.

Here you go. It is GX IEC Developer.
Forum: LIVE PLC Questions And Answers November 21st, 2018, 04:42 AM
Replies: 13
Views: 701
Posted By goghie
FX3U-24MR Does not have built in analogues. You...

FX3U-24MR Does not have built in analogues. You can add extension modules on right side of PLC, or one extension board on front of PLC.
Forum: LIVE PLC Questions And Answers November 15th, 2018, 01:50 PM
Replies: 6
Views: 287
Posted By goghie
So you can program FX3U, and configure for...

So you can program FX3U, and configure for example FX3U-ENET for Modbus TCP/IP on port 502, or for MC protocol on some other port, and than you can program second HMI to access to PLC.
Forum: LIVE PLC Questions And Answers November 15th, 2018, 12:15 PM
Replies: 8
Views: 327
Posted By goghie
FX3U-ENET for FX3U, and FX2NC-ENET-ADP for FX2.

FX3U-ENET for FX3U, and FX2NC-ENET-ADP for FX2.
Forum: LIVE PLC Questions And Answers November 15th, 2018, 12:04 PM
Replies: 6
Views: 287
Posted By goghie
So I would presume that it is connected through...

So I would presume that it is connected through side connector (RS422/485/232) on HMI to Mini DIN connector on FX. If the PLC is not the one with built in Ethernet, that means that you need to have...
Forum: LIVE PLC Questions And Answers November 14th, 2018, 03:34 PM
Replies: 6
Views: 287
Posted By goghie
When you connect to FX3 through E W O N router...

When you connect to FX3 through E W O N router your computer sees that PLC as if it is directly connected with LAN cable. You can use SoftGOT or any other solution as long is it programmed/configured...
Forum: LIVE PLC Questions And Answers November 14th, 2018, 02:54 PM
Replies: 19
Views: 1,008
Posted By goghie
Internal model control (IMC). I've found it...

Internal model control (IMC). I've found it useful when there is a big lag in response.
Forum: LIVE PLC Questions And Answers November 12th, 2018, 05:37 PM
Replies: 2
Views: 327
Posted By goghie
45kW DC motor change with AC - advice?

Hi,
I have to retrofit one plant, intended for cream production. There is DC motor 45kW (up to 3000RPM, 440V)which is driving emulsifier and I would like to change it with 55kW VFD driven 400V AC...
Forum: LIVE PLC Questions And Answers November 8th, 2018, 02:12 AM
Replies: 3
Views: 331
Posted By goghie
Register on Mitsubishi Factory Automation and...

Register on Mitsubishi Factory Automation and then you can download a lot of manuals and e-trainings.
Forum: LIVE PLC Questions And Answers November 6th, 2018, 02:49 PM
Replies: 9
Views: 534
Posted By goghie
The other one is 330 Ohm and it is used for...

The other one is 330 Ohm and it is used for two-pair wiring, and 110 Ohm is used for one-pair wiring. To conclude what is in one end needs to be on other end. If SDA and RDA are in short circuit, and...
Forum: LIVE PLC Questions And Answers November 6th, 2018, 01:07 PM
Replies: 9
Views: 534
Posted By goghie
Make sure that you are using the correct terminal...

Make sure that you are using the correct terminal resistor 110 Ohm, 1/2W (3 brown stripes and one silver or gold), connected between RDA and RDB. Cable should be shielded twisted pair. Shield should...
Forum: LIVE PLC Questions And Answers November 6th, 2018, 11:16 AM
Replies: 9
Views: 534
Posted By goghie
What is the type of robot controller?

What is the type of robot controller?
Forum: LIVE PLC Questions And Answers November 6th, 2018, 09:19 AM
Replies: 5
Views: 306
Posted By goghie
Yes and no. %MW is not address for...

Yes and no.
%MW is not address for real/floating it is for integer.
Simple solution would be to convert it in integer and result (integer) would be without float part, but if it is %MW than i...
Forum: LIVE PLC Questions And Answers November 6th, 2018, 09:14 AM
Replies: 9
Views: 534
Posted By goghie
Because of characteristic impedance. You want to...

Because of characteristic impedance. You want to eliminate reflections - but you need to mach resistance in order to absorb it.
You posted previously one picture of panel where the cables look like...
Forum: LIVE PLC Questions And Answers November 2nd, 2018, 02:21 PM
Replies: 12
Views: 1,187
Posted By goghie
https://www.youtube.com/watch?v=PUUNKi_TS54

https://www.youtube.com/watch?v=PUUNKi_TS54
Forum: LIVE PLC Questions And Answers October 16th, 2018, 01:24 PM
Replies: 17
Views: 673
Posted By goghie
Sorry, I must have misunderstood you. It seemed...

Sorry, I must have misunderstood you. It seemed to me that you complain because you need to pay somebody to do it. Sorry once again, my bad English.
Forum: LIVE PLC Questions And Answers October 16th, 2018, 12:25 PM
Replies: 17
Views: 673
Posted By goghie
Yes, but that is totaly legal. We are investing,...

Yes, but that is totaly legal. We are investing, constantly learning and taking ressponsability for finishing the job right and we pay our living from that. On other side you can go after work and...
Forum: LIVE PLC Questions And Answers October 5th, 2018, 05:30 AM
Replies: 15
Views: 2,097
Posted By goghie
I think GX IEC Developer is Codesys V2. Extension...

I think GX IEC Developer is Codesys V2. Extension of file is .pro and it has that look and syntax..
Forum: LIVE PLC Questions And Answers October 2nd, 2018, 09:59 AM
Replies: 18
Views: 761
Posted By goghie
Is it 64bit Windows, and if yes - please give me...

Is it 64bit Windows, and if yes - please give me some directions how to do it?
Showing results 1 to 25 of 267

 