You are not registered yet. Please click here to register!


 
 
plc storereviewsdownloads
This board is for PLC Related Q&A ONLY. Please DON'T use it for advertising, etc.
 
Try our online PLC Simulator- FREE.  Click here now to try it.

---------->>>>>Get FREE PLC Programming Tips

New Here? Please read this important info!!!


Go Back   PLCS.net - Interactive Q & A > Search Forums

Showing results 1 to 25 of 140
Search took 0.02 seconds.
Search: Posts Made By: remullis
Forum: LIVE PLC Questions And Answers February 21st, 2019, 02:58 PM
Replies: 4
Views: 257
Posted By remullis
Ah, I removed the == and it works! SD11FOP_OP <5....

Ah, I removed the == and it works! SD11FOP_OP <5. Thanks for the help.
Forum: LIVE PLC Questions And Answers February 21st, 2019, 02:40 PM
Replies: 4
Views: 257
Posted By remullis
I put this condition in but I am getting an error...

I put this condition in but I am getting an error for another operand?

In " Condition": SD11FOP_OP ==<5 (On true if less than 5)

In the large window script: Show "11 OP ALARM";
Forum: LIVE PLC Questions And Answers February 21st, 2019, 01:33 PM
Replies: 4
Views: 257
Posted By remullis
WW adding popup condition for window

I have created a window "Popup", and I would like to show this window when I reach a certain analog value. The tag is created in WW so I would be monitoring that one. The WW tag is SD11FOM_OP...
Forum: LIVE PLC Questions And Answers January 23rd, 2019, 09:34 AM
Replies: 0
Views: 110
Posted By remullis
KEB Combivert drive to PF700 or 753

Hello all,

I am working on an old bagger that is giving a EUP fault which is undervoltage and intermittent. Electrical power cycles and gets the drive back going but they say they cant detect any...
Forum: LIVE PLC Questions And Answers December 17th, 2018, 09:47 AM
Replies: 1
Views: 290
Posted By remullis
I figured out that I am exceeding the amount of...

I figured out that I am exceeding the amount of memory in the processor. This PLC is using a plc5/20e with 16384 words of memory. It currently is using 16242 words. I deleted some logic and was able...
Forum: LIVE PLC Questions And Answers December 17th, 2018, 08:47 AM
Replies: 1
Views: 290
Posted By remullis
PLC5 allen bradley access priviledge

I have been working within a file for several days and this morning I am getting a "Access Violation to Current Processor" error? I was just in the program Friday, but this morning I can't accept...
Forum: LIVE PLC Questions And Answers November 28th, 2018, 11:30 AM
Replies: 4
Views: 233
Posted By remullis
I just realized this register list is for Modbus....

I just realized this register list is for Modbus. I am communicating through E/IP. Anyone have anything on this protocol.
Forum: LIVE PLC Questions And Answers November 28th, 2018, 11:26 AM
Replies: 4
Views: 233
Posted By remullis
I downloaded the register map and will give it a...

I downloaded the register map and will give it a shot. Thanks for the information.
Forum: LIVE PLC Questions And Answers November 28th, 2018, 09:00 AM
Replies: 4
Views: 233
Posted By remullis
PM5563 Schneider (sq D) power monitor

Has anyone had success mapping the PM5563 to controllogix. I am able to get information from the unit to the plc but I don't know the actual mapping and what is needed to manipulate the data. I have...
Forum: LIVE PLC Questions And Answers November 8th, 2018, 02:05 PM
Replies: 3
Views: 344
Posted By remullis
The | for divide solved my error for the...

The | for divide solved my error for the equation. I am able to scale the silo's that are linear (flat bottom). I have figured the silo capacity for a non linear with a cone but of course with the...
Forum: LIVE PLC Questions And Answers November 7th, 2018, 02:21 PM
Replies: 3
Views: 344
Posted By remullis
cpt function and doing the math for silo capacity

I am working with plc5.

I am using the CPT function but getting errors.

The level of the silo is inputed at F51:031. The silo cuft is 3393 with 30' overall height. I need this computed and...
Forum: LIVE PLC Questions And Answers October 3rd, 2018, 01:14 PM
Replies: 4
Views: 368
Posted By remullis
I just realized SCP function is not used in a...

I just realized SCP function is not used in a PLC5. What I want to do is scale.

Tank level 0-30'
and be linear 0-3393cuft, then cpt the cuft*density.
Forum: LIVE PLC Questions And Answers October 3rd, 2018, 12:48 PM
Replies: 4
Views: 368
Posted By remullis
Ken, Right, so I know that my tank volume is...

Ken,

Right, so I know that my tank volume is 3393 cuft. I currently know where my level is, for example 15'0 in a 30' tank. What instruction could I use for scaling the 15' to 1/2 of 3393 cuft. I...
Forum: LIVE PLC Questions And Answers October 3rd, 2018, 12:01 PM
Replies: 4
Views: 368
Posted By remullis
PLC 5 calculate tons of slurry in silo

We currently use a level indicator in silo's where I would like to also give the operator tons of slurry based on the percentage of tank filled.

What instruction would be best suited for scaling...
Forum: LIVE PLC Questions And Answers October 1st, 2018, 08:41 AM
Replies: 5
Views: 600
Posted By remullis
Thanks guys, Jesper answered my first question...

Thanks guys, Jesper answered my first question and Jeff answered the second one I was about to ask. I was not familiar with Capacitor forming. Good information!
Forum: LIVE PLC Questions And Answers October 1st, 2018, 08:02 AM
Replies: 5
Views: 600
Posted By remullis
vfd shelf life

I was just presented this question do VFD's have a shelf life specifically capacitor failures prematurely. I would think this should not be an issue, but I thought I would present it to the forum and...
Forum: LIVE PLC Questions And Answers August 15th, 2018, 01:25 PM
Replies: 0
Views: 222
Posted By remullis
drive exec and rslinx

I have two PC's with Rockwell Software running on them so I can access the same equipment and files using rslogix5000, device net and drive exec. On one of the systems I can't go online with drives,...
Forum: LIVE PLC Questions And Answers July 20th, 2018, 12:38 PM
Replies: 3
Views: 948
Posted By remullis
Ken, This was great information. We always...

Ken,

This was great information. We always setup the our drives for 70hz (par 55) with max speed at 60hz. Parameter 83 is set to 10.

We give the operators control of the motors 0-100% of the...
Forum: LIVE PLC Questions And Answers July 19th, 2018, 05:55 PM
Replies: 3
Views: 948
Posted By remullis
700h vfd writing freq command to the drive

Typically our 700h drives get the freq output number from the Plc by multiplying the percent speed, ex. 50% x 280.86 which writes to a predefined tag for the 700h. Our integrator is now writing ex....
Forum: LIVE PLC Questions And Answers June 28th, 2018, 10:10 AM
Replies: 1
Views: 351
Posted By remullis
powerflex 700 power loss control

During a power interruption( quick blip) we had a fan that reversed direction and stayed running. I have the power loss parameters set to "Coast". I am think the fan draft caused the fan to start...
Forum: LIVE PLC Questions And Answers May 15th, 2018, 03:47 PM
Replies: 3
Views: 334
Posted By remullis
Sorry about the picture. The AOI's don't seem to...

Sorry about the picture. The AOI's don't seem to be interactive, they are Greyed out.
Forum: LIVE PLC Questions And Answers May 15th, 2018, 03:27 PM
Replies: 3
Views: 334
Posted By remullis
add on instructions, function block questions

I am troubleshooting an outside vendor program where add on instructions are used as well as these user defined function blocks. I am trying to figure out what calls for the specific solenoid to be...
Forum: LIVE PLC Questions And Answers December 14th, 2017, 03:41 PM
Replies: 4
Views: 1,075
Posted By remullis
factory talk activation expired

I have an ex employee laptop which has rslogix 5000 software and it has the factory talk expired. When I try to look up the activation it does not show in the directory. Would rockwell be able to...
Forum: LIVE PLC Questions And Answers July 18th, 2017, 10:21 AM
Replies: 2
Views: 338
Posted By remullis
Ok, I just went there and I can see the status...

Ok, I just went there and I can see the status values, thanks for the quick response.
Forum: LIVE PLC Questions And Answers July 18th, 2017, 09:07 AM
Replies: 2
Views: 338
Posted By remullis
WonderWare - How to see state of tags

I am using WW version 2012. I think there is a way to actually monitor state of tags and real numbers. Is this correct, and how do I monitor that?

Thanks
Rich