Search: Posts Made By: KalleOlsen
Forum: LIVE PLC Questions And Answers August 30th, 2018, 09:37 AM
Replies: 44
Views: 1,896
Posted By KalleOlsen
Siemens' weighing/dosing system is called...

Siemens' weighing/dosing system is called Siwarex. There are lots of models.

K
Forum: LIVE PLC Questions And Answers August 28th, 2018, 10:43 AM
Replies: 44
Views: 1,896
Posted By KalleOlsen
To look for the missing PBs you need this info: ...

To look for the missing PBs you need this info:


The a list of MC5-codes, see from page 26

http://usedplcs.co.uk/manuals/siemens/S5/115UTHEN.PDF


Layout of the block preheader, see...
Forum: LIVE PLC Questions And Answers August 26th, 2018, 01:54 PM
Replies: 44
Views: 1,896
Posted By KalleOlsen
Could it be that your type of machine is a part...

Could it be that your type of machine is a part of a bigger system and that irrelevant program parts are deleted / omitted by the OEM?
Forum: LIVE PLC Questions And Answers August 26th, 2018, 01:50 PM
Replies: 44
Views: 1,896
Posted By KalleOlsen
As I said earlier; I mean that this type of CPU...

As I said earlier; I mean that this type of CPU runs OK even if PBs are missing. But if a non existing DB (-area) is accessed by the user program, it will stop.




Kalle
Forum: LIVE PLC Questions And Answers August 26th, 2018, 03:36 AM
Replies: 44
Views: 1,896
Posted By KalleOlsen
EEPROM doesn't have anything extra than what is...

EEPROM doesn't have anything extra than what is shown in PLC directory?

Correct


Then where are these PB16 to PBxxxx located?


Good question.
Forum: LIVE PLC Questions And Answers August 25th, 2018, 12:50 PM
Replies: 44
Views: 1,896
Posted By KalleOlsen
If i remember correctly, you can read from the...

If i remember correctly, you can read from the EPROM by going online with the CPU. I recon that is what you already have done.




Kalle
Forum: LIVE PLC Questions And Answers August 25th, 2018, 02:24 AM
Replies: 44
Views: 1,896
Posted By KalleOlsen
It sounds like a memory hickup. What kind...

It sounds like a memory hickup.


What kind of memory module is it (RAM/(E)EPROM)?


Kalle
Forum: LIVE PLC Questions And Answers August 24th, 2018, 12:10 PM
Replies: 44
Views: 1,896
Posted By KalleOlsen
Are there missing functions in the plant/machine,...

Are there missing functions in the plant/machine, or are you just curious why those PBs aren't there?
Forum: LIVE PLC Questions And Answers August 24th, 2018, 11:08 AM
Replies: 44
Views: 1,896
Posted By KalleOlsen
Hi! Do you mean the online directory in the...

Hi!
Do you mean the online directory in the CPU?




I think the 941 will run happily even if some PBs are lacking.


Kalle
Forum: LIVE PLC Questions And Answers August 3rd, 2018, 10:03 AM
Replies: 6
Views: 378
Posted By KalleOlsen
The converter I suggested can be used for...

The converter I suggested can be used for programming with IBH-S5W, and it supports S7-protocols as Put/Get, which is much more common on modern HMI systems than the cheaper cable and AS511...
Forum: LIVE PLC Questions And Answers August 3rd, 2018, 05:54 AM
Replies: 6
Views: 378
Posted By KalleOlsen
Hi! Try this adapter from IBH: ...

Hi!
Try this adapter from IBH:

https://www.ibhsoftec.com/IBH-Link-S5-PP-Eng?gclid=EAIaIQobChMI0bfup9rQ3AIVnIKyCh1a5QZsEAMYASAAEgI9KvD_BwE

Kalle
Forum: LIVE PLC Questions And Answers March 5th, 2018, 11:46 AM
Replies: 10
Views: 559
Posted By KalleOlsen
Hi Mohamed! You might find something useful...

Hi Mohamed!

You might find something useful here:

http://w3.siemens.com/mcms/sce/en/advanced_training/training_material/university-modules/pages/default.aspx

Kalle
Forum: LIVE PLC Questions And Answers March 4th, 2018, 03:32 PM
Replies: 15
Views: 907
Posted By KalleOlsen
Hi Chris! Some questions: -Is there an...

Hi Chris!
Some questions:

-Is there an Eprom in the CP-card?

If no,
- Do you have the CP config file?

***
Forum: LIVE PLC Questions And Answers December 27th, 2016, 04:30 AM
Replies: 6
Views: 1,588
Posted By KalleOlsen
Hi! If you can use CFC, you can assign a...

Hi!
If you can use CFC, you can assign a parameter 'readback=true' to the In and In-Out variables of the FB. If you store values here, they can be read from the CPU and saved in the offline program...
Forum: LIVE PLC Questions And Answers December 19th, 2016, 11:48 AM
Replies: 4
Views: 1,186
Posted By KalleOlsen
Hi cardosocea! Spoil your Christmas here:...

Hi cardosocea!


Spoil your Christmas here:
Special University Modules | PCS 7 - Siemens Automation Cooperates with Education - Siemens...
Forum: LIVE PLC Questions And Answers November 20th, 2016, 04:06 AM
Replies: 7
Views: 1,122
Posted By KalleOlsen
Lifted, you may find something helpful on this...

Lifted, you may find something helpful on this site:

http://www.contactandcoil.com/patterns-of-ladder-logic-programming/step/


Kalle
Forum: LIVE PLC Questions And Answers November 9th, 2016, 10:48 AM
Replies: 4
Views: 901
Posted By KalleOlsen
According to this manual ... ...

According to this manual ...
https://cache.industry.siemens.com/dl/files/570/1887570/att_58938/v1/op5_15_e.pdf
... the OP has a Loop-through-mode. With an 15p-25p adapter you might be able to...
Forum: LIVE PLC Questions And Answers November 9th, 2016, 10:23 AM
Replies: 4
Views: 901
Posted By KalleOlsen
Hi! If you have a 95U with 2 interfaces,...

Hi!

If you have a 95U with 2 interfaces, AS511 and Sinec L1, you can monitor variables via the L1 interface. I donīt think itīs possible to load program or data blocks.

With a grain of salt
...
Forum: LIVE PLC Questions And Answers November 5th, 2016, 10:07 AM
Replies: 16
Views: 2,628
Posted By KalleOlsen
Here are cables from IBH: ...

Here are cables from IBH:



https://www.ibhsoftec.com/epages/63444704.sf/en_GB/?ViewObjectPath=%2FShops%2F63444704%2FCategories%2FProdukte%2FHardware%2F%22S5%20Schnittstellen%22


I've used...
Forum: LIVE PLC Questions And Answers November 5th, 2016, 09:59 AM
Replies: 16
Views: 2,628
Posted By KalleOlsen
More info:

More info:
Forum: LIVE PLC Questions And Answers November 5th, 2016, 09:56 AM
Replies: 16
Views: 2,628
Posted By KalleOlsen
Here's the pin layout of the AS511 15pin variant....

Here's the pin layout of the AS511 15pin variant.
This is a faximile from the manual I found here (page 216):
http://gaxons.com/files/s5/135uen.pdf

In case your adapter doesn't have current...
Forum: LIVE PLC Questions And Answers November 5th, 2016, 09:46 AM
Replies: 16
Views: 2,628
Posted By KalleOlsen
Check the current sources and directions vs this...

Check the current sources and directions vs this drawing.
Forum: LIVE PLC Questions And Answers November 2nd, 2016, 11:10 AM
Replies: 10
Views: 1,754
Posted By KalleOlsen
Hi! I don't have TIA here (don't miss it...

Hi!

I don't have TIA here (don't miss it either), but if you could insert an empty box and give it the name of the STAT, then maybe...

Kalle
Forum: LIVE PLC Questions And Answers October 20th, 2016, 03:38 PM
Replies: 11
Views: 1,800
Posted By KalleOlsen
You can find a manual here: ...

You can find a manual here:
https://support.industry.siemens.com/cs/document/1085937/s5-115u-programmable-controller?dti=0&lc=en-NO

Here's the meaning when the stop led is flashing:

Memory...
Forum: LIVE PLC Questions And Answers October 19th, 2016, 02:50 PM
Replies: 11
Views: 1,800
Posted By KalleOlsen
Man, you need to go online and check the...

Man, you need to go online and check the diagnostics!

Or we could have a wild guess competition...

Kalle
Showing results 1 to 25 of 500

 
Forum Jump

All times are GMT -5. The time now is 12:23 PM.


.