You are not registered yet. Please click here to register!


 
 
plc storereviewsdownloads
This board is for PLC Related Q&A ONLY. Please DON'T use it for advertising, etc.
 
Try our online PLC Simulator- FREE.  Click here now to try it.

---------->>>>>Get FREE PLC Programming Tips

New Here? Please read this important info!!!


Go Back   PLCS.net - Interactive Q & A > Search Forums

Showing results 1 to 25 of 500
Search took 1.03 seconds.
Search: Posts Made By: harryting
Forum: LIVE PLC Questions And Answers September 18th, 2018, 12:53 PM
Replies: 104
Views: 10,450
Posted By harryting
that's legal here in WA. Tesla's problem isn't...

that's legal here in WA. Tesla's problem isn't limited to one person.

My opinion haven't changed. As amazing as their product is to consumers, it's not due to some proprietary technology. It's...
Forum: LIVE PLC Questions And Answers September 17th, 2018, 12:10 PM
Replies: 8
Views: 186
Posted By harryting
You mean bits or integer (word)? The format for...

You mean bits or integer (word)? The format for an integer array would be INT[x]
Forum: LIVE PLC Questions And Answers September 12th, 2018, 05:18 PM
Replies: 6
Views: 181
Posted By harryting
First, I would be really surprised if someone...

First, I would be really surprised if someone installed a new 90-30 in 2016. That PLC is very dated and went end-of-life in 2017. Having said that, you shouldn't have any issue with backward...
Forum: LIVE PLC Questions And Answers September 12th, 2018, 01:45 PM
Replies: 4
Views: 234
Posted By harryting
Here's what the red lion tech support send to me...

Here's what the red lion tech support send to me when I asked a simliar question:

http://www.redlion.net/sites/default/files/1299/7109/Crimson%203.0%20-%20Using%20the%20OPC%20Master%20Driver.pdf
...
Forum: LIVE PLC Questions And Answers September 11th, 2018, 11:32 AM
Replies: 6
Views: 306
Posted By harryting
This is probably not answering your question but...

This is probably not answering your question but typically, one would get a special encoder PLC module.

Since you said it "works". i"m curious. The PLC logic must be tracking the phase, right?
Forum: LIVE PLC Questions And Answers September 7th, 2018, 09:59 AM
Replies: 6
Views: 189
Posted By harryting
Yes, you need the Ethernet Device driver when...

Yes, you need the Ethernet Device driver when using VPN. However, you shouldn't need the ":EIP" at the end.
Forum: LIVE PLC Questions And Answers September 6th, 2018, 11:34 AM
Replies: 23
Views: 870
Posted By harryting
It's worth pointing out that it's way more...

It's worth pointing out that it's way more stringent on the DCS side. GE will not sell their Mark VIe system to anyone else. They have to be the integrator.
Forum: LIVE PLC Questions And Answers September 6th, 2018, 10:58 AM
Replies: 14
Views: 359
Posted By harryting
Well, it's hard to do this troubleshooting like...

Well, it's hard to do this troubleshooting like this. We can only give wild *** guesses even if we can open the offline program.

Is the output turned on when it supposed to? Is there a...
Forum: LIVE PLC Questions And Answers September 6th, 2018, 10:08 AM
Replies: 23
Views: 870
Posted By harryting
Yes and no... This model helps to pay for...

Yes and no...

This model helps to pay for local distributor to hire local technical support people and they saved me a few times. But also throw a monkey wrench into project that are sourced 3...
Forum: LIVE PLC Questions And Answers September 5th, 2018, 03:30 PM
Replies: 8
Views: 328
Posted By harryting
I missed that. I'm sure you considered it...

I missed that.

I'm sure you considered it but I would really push for an upgrade/conversion to some more supportable.
Forum: LIVE PLC Questions And Answers September 5th, 2018, 02:44 PM
Replies: 8
Views: 328
Posted By harryting
iFix key are backward compatible. So you can...

iFix key are backward compatible. So you can always get a current version key and it should work. However, I never tried something as old as 2.5 though.
Forum: LIVE PLC Questions And Answers September 4th, 2018, 06:27 PM
Replies: 3
Views: 202
Posted By harryting
Interesting, they seemed to expanded the list of...

Interesting, they seemed to expanded the list of protocol they support since the last time I checked a few years ago. Now they support DNP3 Master and Slave. I'm still working on my Logix L62 to...
Forum: LIVE PLC Questions And Answers August 30th, 2018, 11:53 AM
Replies: 11
Views: 877
Posted By harryting
Well, have you tried to reinstall but running the...

Well, have you tried to reinstall but running the install with "run as admin" option? This tactic have helped me on quite a few software from smaller outfits.

iFix is like a DOS program that's...
Forum: LIVE PLC Questions And Answers August 30th, 2018, 11:04 AM
Replies: 19
Views: 1,036
Posted By harryting
Hot dog machine. Someone asked for codes to...

Hot dog machine.

Someone asked for codes to a "hot dog" machine once.
Forum: LIVE PLC Questions And Answers August 28th, 2018, 05:29 PM
Replies: 11
Views: 877
Posted By harryting
Kick IT out of the plant.

Kick IT out of the plant.
Forum: LIVE PLC Questions And Answers August 28th, 2018, 12:07 PM
Replies: 30
Views: 1,162
Posted By harryting
I would keep trying, there has to be place that...

I would keep trying, there has to be place that got both AB and Siemens. At the same time, I'm a bit befuddled on why you want to learn Siemens so much, after all, it doesn't have that much of a...
Forum: LIVE PLC Questions And Answers August 28th, 2018, 11:33 AM
Replies: 6
Views: 397
Posted By harryting
bots?

bots?
Forum: LIVE PLC Questions And Answers August 27th, 2018, 09:52 AM
Replies: 18
Views: 728
Posted By harryting
Here's an very inexpensive option if you putting...

Here's an very inexpensive option if you putting one of these at home:

Search for "standing desk legs" then mounted it on a IKEA desk top.
Forum: LIVE PLC Questions And Answers August 27th, 2018, 09:48 AM
Replies: 7
Views: 225
Posted By harryting
Well, I got it to "work" but I want to to come...

Well, I got it to "work" but I want to to come back and close the loops on this.

I put the "work" in quotes because there's some odd behavior. On reboot, it takes about 10 minutes to go through...
Forum: LIVE PLC Questions And Answers August 21st, 2018, 12:14 PM
Replies: 7
Views: 225
Posted By harryting
I think I answered my own question. I am...

I think I answered my own question.

I am able to add the ethernet card to the PLC backplane then add the ethernet card for the other PLC's backplane... and so on. RSLinx Enterprise doesn't seem...
Forum: LIVE PLC Questions And Answers August 21st, 2018, 11:30 AM
Replies: 7
Views: 225
Posted By harryting
Thanks Geo. It's a version 7 firmware. It's...

Thanks Geo. It's a version 7 firmware.

It's unclear, however, from KB 47661, that it can communicate THROUGH the controlnet, pass through a PLC backplane and out through a Etherent card on the...
Forum: LIVE PLC Questions And Answers August 21st, 2018, 09:57 AM
Replies: 7
Views: 225
Posted By harryting
Panelview Plus ControlNet Comm setup

I haven't messed with ControlNet or Panelview + in a long while so I appreciate someone give me some pointers.

Trying to install a new PV+ on controlnet, the reason is this location got ControlNet...
Forum: LIVE PLC Questions And Answers August 17th, 2018, 01:52 PM
Replies: 14
Views: 470
Posted By harryting
Is it just one single tag that's not working on...

Is it just one single tag that's not working on the screen or is it all the tags?

Have you tried to create a tag from scratch and add on to the screen to see if it works?
Forum: LIVE PLC Questions And Answers August 15th, 2018, 10:48 AM
Replies: 47
Views: 6,391
Posted By harryting
2008... arggh, right at the start of the Great...

2008... arggh, right at the start of the Great Recession.

Whatever happened to surferb?
Forum: LIVE PLC Questions And Answers August 15th, 2018, 10:36 AM
Replies: 14
Views: 470
Posted By harryting
I maybe off too since I never messed with 3.5,...

I maybe off too since I never messed with 3.5, but does the tag value show up in database manager? In current iFix version you can see real time value in Databasemanager.
Showing results 1 to 25 of 500

 
Forum Jump

All times are GMT -5. The time now is 05:17 AM.


.