Search: Posts Made By: Steve Bailey
Forum: LIVE PLC Questions And Answers Today, 01:06 PM
Replies: 12
Views: 145
Posted By Steve Bailey
I looked at the ML1400 reference manual. If I'm...

I looked at the ML1400 reference manual. If I'm reading it correctly, you only get the remainder in S:13 if you're doing the DIV with INTs. If you use LONGs you get the rounded result.


Since I...
Forum: LIVE PLC Questions And Answers Today, 12:17 PM
Replies: 5
Views: 90
Posted By Steve Bailey
GE sold their PLC business to Emerson.

GE sold their PLC business to Emerson.
Forum: LIVE PLC Questions And Answers Today, 12:12 PM
Replies: 12
Views: 145
Posted By Steve Bailey
When you do an integer divide, is there an S-bit...

When you do an integer divide, is there an S-bit that tells you if the quotient was rounded up?


Would this work?


Number of Revs = Pulse count divided by 10000
If rounded up, Number of Revs...
Forum: LIVE PLC Questions And Answers Today, 12:03 PM
Replies: 10
Views: 238
Posted By Steve Bailey
In my area some of the schools have beefed up...

In my area some of the schools have beefed up their wifi so that people with slow connections at home can drive to the school parking lot and log in there to get access to the lessons.
Forum: LIVE PLC Questions And Answers Today, 11:23 AM
Replies: 12
Views: 145
Posted By Steve Bailey
I have a very old (1996) instruction set manual...

I have a very old (1996) instruction set manual for the SLC and MicroLogix 1000 which describes the Double Divide (DDV) function. According to that manual, The unrounded quotient of the DDV is placed...
Forum: LIVE PLC Questions And Answers Today, 10:56 AM
Replies: 5
Views: 90
Posted By Steve Bailey
Is the physical connection between the drive and...

Is the physical connection between the drive and the PLC serial or Ethernet? Does the drive support Modbus?
Forum: LIVE PLC Questions And Answers Yesterday, 04:53 PM
Replies: 8
Views: 222
Posted By Steve Bailey
What have you tried so far? We tend not to simply...

What have you tried so far? We tend not to simply hand out answers to homework problems.
If this is an extra credit problem, can you think of any way the security light with timed shutoff is similar...
Forum: LIVE PLC Questions And Answers April 3rd, 2020, 05:53 PM
Replies: 13
Views: 432
Posted By Steve Bailey
Why not? It can't hurt to post in more than one...

Why not? It can't hurt to post in more than one forum. There may be Ignition users here that don't follow the IA forum.
Forum: LIVE PLC Questions And Answers April 3rd, 2020, 04:21 PM
Replies: 13
Views: 432
Posted By Steve Bailey
Convert the out-of-range numbers to integers with...

Convert the out-of-range numbers to integers with an implied decimal point?
Forum: LIVE PLC Questions And Answers April 3rd, 2020, 08:40 AM
Replies: 16
Views: 861
Posted By Steve Bailey
Fifty volts doesn't seem like enough range, but...

Fifty volts doesn't seem like enough range, but could it be a static detector?
Forum: LIVE PLC Questions And Answers April 3rd, 2020, 08:25 AM
Replies: 16
Views: 861
Posted By Steve Bailey
The probe looks like a phone jack. Is it...

The probe looks like a phone jack. Is it insulated?
Forum: LIVE PLC Questions And Answers April 1st, 2020, 06:42 PM
Replies: 14
Views: 673
Posted By Steve Bailey
Standard procedure for homework help is you show...

Standard procedure for homework help is you show us some work, we'll critique it and try to steer you in the right direction. So, show us what you've done so far.
Forum: LIVE PLC Questions And Answers March 30th, 2020, 07:12 PM
Replies: 15
Views: 476
Posted By Steve Bailey
I, for one, fail to see why you need the ladder...

I, for one, fail to see why you need the ladder logic in the PLC to perform any "cloud analytics". I can understand needing to read the data values, but not the underlying logic.
Forum: LIVE PLC Questions And Answers March 30th, 2020, 04:12 PM
Replies: 15
Views: 476
Posted By Steve Bailey
I think you would need to launch the programming...

I think you would need to launch the programming software and use it's upload/download utility. The ability to transfer the program is not included in the Modbus function codes.
Forum: LIVE PLC Questions And Answers March 30th, 2020, 10:33 AM
Replies: 8
Views: 330
Posted By Steve Bailey
Sorry, but I don't know enough about Factory Talk...

Sorry, but I don't know enough about Factory Talk Studio to offer an answer. But I was recently faced with the same issue and had to use the brute force method.
One would hope that the original...
Forum: LIVE PLC Questions And Answers March 28th, 2020, 07:07 PM
Replies: 175
Views: 9,726
Posted By Steve Bailey
I'm retired and available with no other competing...

I'm retired and available with no other competing obligations.
Contact me at Stephen dot bailey2 at Verizon dot net or by private message through this site.
I have vast experience with GE PLCs...
Forum: LIVE PLC Questions And Answers March 28th, 2020, 04:04 PM
Replies: 301
Views: 20,370
Posted By Steve Bailey
That's a great idea! I just did followed suit....

That's a great idea! I just did followed suit. Perhaps Phil could make a sticky thread as a clearinghouse for a broader offering. PLCTalk members post their availability and areas of expertise....
Forum: LIVE PLC Questions And Answers March 27th, 2020, 08:13 AM
Replies: 23
Views: 427
Posted By Steve Bailey
If you already have a copy of the RSLogix 500...

If you already have a copy of the RSLogix 500 project file that includes the rung comments and variable descriptions, you can make a printout that includes them.
If you are starting from a brand new...
Forum: LIVE PLC Questions And Answers March 27th, 2020, 07:49 AM
Replies: 23
Views: 427
Posted By Steve Bailey
The issue with a controller programmed using...

The issue with a controller programmed using RSLogix 500 is that the rung comments and descriptions don't get sent to the CPU. That information only exists in the RSLogix 500 project files. So when...
Forum: LIVE PLC Questions And Answers March 26th, 2020, 12:44 PM
Replies: 6
Views: 140
Posted By Steve Bailey
Powermation or GEXPro

Powermation or GEXPro
Forum: LIVE PLC Questions And Answers March 26th, 2020, 12:21 PM
Replies: 6
Views: 140
Posted By Steve Bailey
Are you sure the EEPROM you put in the CPU is...

Are you sure the EEPROM you put in the CPU is compatible? I have only ever written to EEPROMs I purchased from my GE supplier.
Forum: LIVE PLC Questions And Answers March 26th, 2020, 12:03 PM
Replies: 6
Views: 140
Posted By Steve Bailey
I may be wrong, but I think the transfer is...

I may be wrong, but I think the transfer is between RAM and EEPROM. You will need to send the program and configuration from LM90 to the CPU first, then the write to EEPROM is from CPU RAM to EEPROM.
Forum: LIVE PLC Questions And Answers March 21st, 2020, 08:47 AM
Replies: 7
Views: 439
Posted By Steve Bailey
I'm a long way from being a Rockwell expert, but...

I'm a long way from being a Rockwell expert, but one thing I've learned is that the scope of tags is often the reason for their unexpected behavior.
Forum: LIVE PLC Questions And Answers March 21st, 2020, 06:31 AM
Replies: 7
Views: 439
Posted By Steve Bailey
Is the timer a program tag or controller tag?

Is the timer a program tag or controller tag?
Forum: LIVE PLC Questions And Answers March 20th, 2020, 06:41 PM
Replies: 3
Views: 170
Posted By Steve Bailey
The programming software is called Proficy...

The programming software is called Proficy Machine edition. Communication with that model PLC is serial, not Ethernet, so you will need a serial port on the computer that runs Proficy. That could be...