Search: Posts Made By: Aabeck
Forum: LIVE PLC Questions And Answers Today, 05:56 PM
Replies: 12
Views: 216
Posted By Aabeck
I dug around the AdvancedHMI forum and found...

I dug around the AdvancedHMI forum and found this:

http://advancedhmi.com/forum/index.php?topic=227.msg759#msg759

The IP address of a driver can be changed after it is stopped.
Forum: LIVE PLC Questions And Answers Today, 12:02 PM
Replies: 12
Views: 216
Posted By Aabeck
lostcontrol, I wasn't aware of that, it...

lostcontrol,

I wasn't aware of that, it sounds like an easier way than the multiple screens I was planning.

I will check into doing that.
Forum: LIVE PLC Questions And Answers Today, 10:04 AM
Replies: 12
Views: 216
Posted By Aabeck
Mendonsy, In AdvancedHMI each screen has an...

Mendonsy,

In AdvancedHMI each screen has an Ethernet driver (or multiple ones) that all objects look at for it's tag

All I would have to do is change the IP on the driver for each screen, if...
Forum: LIVE PLC Questions And Answers Today, 09:18 AM
Replies: 12
Views: 216
Posted By Aabeck
Ife, That basically is what I was planning...

Ife,

That basically is what I was planning with Ethernet, clone the panels except for the IP address, and copy and paste HMI screens - I was just wondering if anyone that has done something...
Forum: LIVE PLC Questions And Answers Today, 08:37 AM
Replies: 12
Views: 216
Posted By Aabeck
I will be using ControlLogic PLC's. Each...

I will be using ControlLogic PLC's.

Each tank is to be an isolated cell so one can be pulled out for service without interfering with the others and for additional tanks to be added after the...
Forum: LIVE PLC Questions And Answers Today, 07:17 AM
Replies: 12
Views: 216
Posted By Aabeck
One HMI To Multiple PLC's Best Practice

I am designing the control for a system of processing tanks, each with it's own PLC and controlled by one PC running AdvancedHMI. This is the first system like this I am designing that will consist...
Forum: LIVE PLC Questions And Answers February 22nd, 2018, 04:50 PM
Replies: 12
Views: 307
Posted By Aabeck
Right click on the RSS file and select "Compress"...

Right click on the RSS file and select "Compress" or "Send To Compressed Folder" etc. depending on which OS you have, then post the .ZIP file

I use 7-Zip, a free download from CNET, as long as you...
Forum: LIVE PLC Questions And Answers February 20th, 2018, 07:48 PM
Replies: 17
Views: 434
Posted By Aabeck
Running as administrator works in Windows 7 & 8,...

Running as administrator works in Windows 7 & 8, but in Windows 10 the activations are never created after deleting the files on the old drive even when running as administrator
Forum: LIVE PLC Questions And Answers February 19th, 2018, 10:31 PM
Replies: 10
Views: 267
Posted By Aabeck
I found long ago I was not a user - I have opened...

I found long ago I was not a user - I have opened and repaired so many things with the label "No User Serviceable Parts Inside"
Forum: LIVE PLC Questions And Answers February 19th, 2018, 05:50 PM
Replies: 17
Views: 434
Posted By Aabeck
Another thing with EVRSI activations: If you...

Another thing with EVRSI activations:

If you try to move them using Windows 10: EVMove and EVMoveCF will go through the motions, but not create the activation on the new drive - AFTER it has...
Forum: LIVE PLC Questions And Answers February 19th, 2018, 03:56 PM
Replies: 2
Views: 127
Posted By Aabeck
With 2 types of glue you may want to add...

With 2 types of glue you may want to add something to sense which hose is connected - not just one was disconnected and reconnected.

That could be as simple as putting a magnet on the hose to one...
Forum: LIVE PLC Questions And Answers February 19th, 2018, 03:26 PM
Replies: 10
Views: 267
Posted By Aabeck
A customer had a backlight go out on a Proface...

A customer had a backlight go out on a Proface and had some Proface's on the shelf - but they all had different length bulbs from every other one.

What I ended up doing was put 2 strips of LED car...
Forum: LIVE PLC Questions And Answers February 19th, 2018, 03:20 PM
Replies: 26
Views: 683
Posted By Aabeck
mhammer, I will double check that when I get...

mhammer,

I will double check that when I get back, but I did a Find All and thought I checked every counter, bit and integer for any duplications.
Forum: LIVE PLC Questions And Answers February 17th, 2018, 02:08 PM
Replies: 4
Views: 175
Posted By Aabeck
I use RS500 V9.0 on 3 Windows 10 computers...

I use RS500 V9.0 on 3 Windows 10 computers without issue.

The only Win10 issue I have ever had was upgrading RSLinx from 3.7 to a newer version - that I had to uninstall & reinstall 3.7.
Forum: LIVE PLC Questions And Answers February 17th, 2018, 11:30 AM
Replies: 7
Views: 178
Posted By Aabeck
Repetition is the key to learning something,...

Repetition is the key to learning something, otherwise grade schools K-12 could be cut down to about 3 weeks!
Forum: LIVE PLC Questions And Answers February 17th, 2018, 06:09 AM
Replies: 7
Views: 178
Posted By Aabeck
Yes, the DC voltage can be anything between 10 to...

Yes, the DC voltage can be anything between 10 to 50 volts.

Being -OB16 they are DC Sourcing outputs, so wire the positive to the VDC terminal, and negative to the DC COM terminal.

For testing...
Forum: LIVE PLC Questions And Answers February 16th, 2018, 06:56 PM
Replies: 7
Views: 178
Posted By Aabeck
First, are you expecting the output card to...

First, are you expecting the output card to provide the power? Or do you have power wired into the proper terminals?

Also, is it a relay, TRIAC, DC source, DC Sink or TTL output?

A TRIAC only...
Forum: LIVE PLC Questions And Answers February 7th, 2018, 12:32 PM
Replies: 37
Views: 1,604
Posted By Aabeck
Just a thought - Since the Tesla isn't...

Just a thought -

Since the Tesla isn't doing anything (monitoring conditions, repeating radio communications, etc.) it would be considered space junk and anyone that wanted to salvage it legally...
Forum: LIVE PLC Questions And Answers February 6th, 2018, 06:19 PM
Replies: 37
Views: 1,604
Posted By Aabeck
Not too off-topic. I'm sure at least one PLC...

Not too off-topic.

I'm sure at least one PLC was used somewhere making parts, maybe fueling, moving, etc...
Forum: LIVE PLC Questions And Answers February 5th, 2018, 10:24 PM
Replies: 26
Views: 683
Posted By Aabeck
Steve, I did exactly that - I added a LEQ...

Steve,

I did exactly that - I added a LEQ S:42 3 in the counter line, and I added a line at the end for GRT S:42 3 RES C5:0 so the counter.ACC would be 0 any second after :03

As a precaution I...
Forum: LIVE PLC Questions And Answers February 5th, 2018, 08:38 PM
Replies: 26
Views: 683
Posted By Aabeck
Here is the zipped file. It is after I cleared...

Here is the zipped file. It is after I cleared out the negative numbers and before I added anything
Forum: LIVE PLC Questions And Answers February 5th, 2018, 07:02 PM
Replies: 26
Views: 880
Posted By Aabeck
Does the VFD in question have a Run FWD and a Run...

Does the VFD in question have a Run FWD and a Run REV input? Or a direction parameter?

Telling the VFD to run a reversed motor in reverse would put the motion forward.
Forum: LIVE PLC Questions And Answers February 5th, 2018, 06:25 PM
Replies: 26
Views: 683
Posted By Aabeck
Daba, I will try moving the OTU, and just to...

Daba,

I will try moving the OTU, and just to see if that does happen add a OTL of an unused bit to see if that latches. But since I added a RES if the second is greater than :03 (in the second...
Forum: LIVE PLC Questions And Answers February 5th, 2018, 04:59 PM
Replies: 26
Views: 683
Posted By Aabeck
Steve, I think the 89 is the value from the...

Steve,

I think the 89 is the value from the last good subtraction, and somehow when it hit these specific values the SUB resulted in a value out of the integers range and that caused the fault.
Forum: LIVE PLC Questions And Answers February 5th, 2018, 04:56 PM
Replies: 26
Views: 683
Posted By Aabeck
Daba, This routine has been in since I...

Daba,

This routine has been in since I started testing the program years ago, not something I just added. It has been in the running machine for over 2 years without any problem, so suddenly the...