Search: Posts Made By: daleroe
Forum: LIVE PLC Questions And Answers January 22nd, 2018, 08:20 AM
Replies: 3
Views: 1,168
Posted By daleroe
Here is an updated link to the manuals. ...

Here is an updated link to the manuals.

www.gtprototype.com/plc/toshiba_ex100/manuals/EX100%20Handy%20Programmer%20Manual_519.pdf
...
Forum: LIVE PLC Questions And Answers November 30th, 2017, 12:24 PM
Replies: 74
Views: 34,353
Posted By daleroe
corrected link

The manual link is no longer valid, here is the updated link:
http://gtprototype.com/plc/toshiba_ex100/manuals/EX20_40%20Plus%20Manual_506.pdf
Forum: LIVE PLC Questions And Answers November 30th, 2017, 11:51 AM
Replies: 5
Views: 935
Posted By daleroe
corrected link

The link is no longer valid, here is the updated link:
http://gtprototype.com/plc/toshiba_ex100/manuals/EX20_40%20Plus%20Manual_506.pdf
Forum: LIVE PLC Questions And Answers December 23rd, 2015, 04:16 PM
Replies: 102
Views: 29,805
Posted By daleroe
Interface and Connector Pictures

Here are the pictures of the interface and connectors
Forum: LIVE PLC Questions And Answers December 23rd, 2015, 04:14 PM
Replies: 102
Views: 29,805
Posted By daleroe
Interface and connector pictures

Pictures of interface and connections.
Forum: LIVE PLC Questions And Answers June 28th, 2012, 11:23 PM
Replies: 102
Views: 29,805
Posted By daleroe
Hello Kos, Sorry I've been away for sometime...

Hello Kos,
Sorry I've been away for sometime with family concerns. Sadly I've been unable to continue the project and bring it to completion. Yes, the current loop adapter as depicted in the...
Forum: LIVE PLC Questions And Answers March 19th, 2012, 05:47 PM
Replies: 102
Views: 29,805
Posted By daleroe
Wow, cool work around! I wondered how you got the...

Wow, cool work around! I wondered how you got the print out with out a hardware lock/key. Thank you for taking the time to create the text files for me.
Forum: LIVE PLC Questions And Answers March 18th, 2012, 06:11 PM
Replies: 102
Views: 29,805
Posted By daleroe
I'm not sure I got a good save of the program...

I'm not sure I got a good save of the program sine one of the files is 0 bytes. I can't open it to find out and since I can't open it I certainly can't print it which is what I need at this point. ...
Forum: LIVE PLC Questions And Answers March 18th, 2012, 01:38 AM
Replies: 102
Views: 29,805
Posted By daleroe
Yeah! :D Thank you jrwb4gbm! :thumb: The...

Yeah! :D Thank you jrwb4gbm! :thumb: The interface works! My problem was the programming port mating connector. It was making intermittent contact which caused the error. Once I got it corrected I...
Forum: LIVE PLC Questions And Answers February 29th, 2012, 12:42 AM
Replies: 102
Views: 29,805
Posted By daleroe
Well, I completed the programming cable and...

Well, I completed the programming cable and hooked it up to the used EX100 Rack off of ebay. I am able to access the PLC via EXPDD ver3 however I keep getting the following error: "(004) Bad...
Forum: LIVE PLC Questions And Answers February 21st, 2012, 03:27 AM
Replies: 102
Views: 29,805
Posted By daleroe
Yeah, the customer has no spares. When I first...

Yeah, the customer has no spares. When I first started this project one of the employees had just replaced some cables that were damaged and the servo motor. I had to replace both EX10-MPI21 cards...
Forum: LIVE PLC Questions And Answers February 20th, 2012, 05:18 PM
Replies: 102
Views: 29,805
Posted By daleroe
COOL! I was able to purchase a used EX100 rack...

COOL! I was able to purchase a used EX100 rack off ebay for a reasonable price to test out the programming cable. I just couldn't bring myself to test out the current loop on the only copy of the...
Forum: LIVE PLC Questions And Answers February 19th, 2012, 02:13 AM
Replies: 102
Views: 29,805
Posted By daleroe
I ordered all the parts from Mouser. They got...

I ordered all the parts from Mouser. They got here Friday so now I'm working on getting it ready to test. I decided to build it on a breadboard to try it out. I couldn't get the right connector...
Forum: LIVE PLC Questions And Answers February 10th, 2012, 01:52 AM
Replies: 102
Views: 29,805
Posted By daleroe
Wow, thank you jrwb4gbm! :thumb: Many thanks! I...

Wow, thank you jrwb4gbm! :thumb: Many thanks! I never could of gotten this far without your help! Once I get it hooked up I'll let you know how it works. Thanks again!
dale
Forum: LIVE PLC Questions And Answers February 5th, 2012, 04:37 AM
Replies: 102
Views: 29,805
Posted By daleroe
I made a print of the pinout for the EX100 PU-11A...

I made a print of the pinout for the EX100 PU-11A programming port. I believe the mating connector is FCN-361P008 although I may have to use FCN-364P008 due to availability. I still have to test...
Forum: LIVE PLC Questions And Answers February 5th, 2012, 01:38 AM
Replies: 102
Views: 29,805
Posted By daleroe
Yes, thank you for clarifying that. :D I...

Yes, thank you for clarifying that. :D

I apologize for any confusion. I thought my question was clear within the context of my previous post. Now that I've read it again, I see that didn't...
Forum: LIVE PLC Questions And Answers February 4th, 2012, 01:24 PM
Replies: 102
Views: 29,805
Posted By daleroe
It would seem that the computer link port on the...

It would seem that the computer link port on the EX100 is a passive current loop which means it needs 5v to operate. I am basing my assumption on the instructions and schematic located on page 4 of...
Forum: LIVE PLC Questions And Answers February 2nd, 2012, 12:37 AM
Replies: 102
Views: 29,805
Posted By daleroe
Yes, I read that also. It is on the second page...

Yes, I read that also. It is on the second page of the CL11 manual (http://gtprototype.com/plc/toshiba_ex100/modules/EX100_CL11_23.pdf) section 7, item #1, "EX100 CPU version 2.1 is required". I...
Forum: LIVE PLC Questions And Answers February 1st, 2012, 08:42 PM
Replies: 102
Views: 29,805
Posted By daleroe
I have tried the TXA&RXA to Data+ with TXB&RXB to...

I have tried the TXA&RXA to Data+ with TXB&RXB to Data- and vice versa at 9600 baud which is what the CL11 is set at. I've also tried the RS-422 settings A to B with T to R and also swapping A to A...
Forum: LIVE PLC Questions And Answers February 1st, 2012, 12:39 AM
Replies: 102
Views: 29,805
Posted By daleroe
Yeah, I agree. From what I've read I thought the...

Yeah, I agree. From what I've read I thought the ADAM-4520 adapter would work. I've tried all variations that are available with the connections and dip switches between the adapter and the...
Forum: LIVE PLC Questions And Answers January 31st, 2012, 01:27 PM
Replies: 102
Views: 29,805
Posted By daleroe
Here are some photos and documentation for...

Here are some photos and documentation for Computer Link Module.

EX100 RACK JPG (http://gtprototype.com/plc/toshiba_ex100/pictures/P1010021.JPG)

EX10-MCL11 JPG...
Forum: LIVE PLC Questions And Answers January 31st, 2012, 01:10 PM
Replies: 102
Views: 29,805
Posted By daleroe
Smile Thank you, I am reviewing the specific pages you...

Thank you, I am reviewing the specific pages you listed in greater detail. I'm in the process of loading all the info I have to the web. While double checking my setup I will document it more...
Forum: LIVE PLC Questions And Answers January 30th, 2012, 11:42 PM
Replies: 102
Views: 29,805
Posted By daleroe
Toshiba EX100 Programming Access Help

Hello,
I am working on a Toshiba EX100 that I need to extract the ladder logic. I'm at the end of my rope. Any help is greatly appreciated. Thank you in advance.
Sincerely
Dale