You are not registered yet. Please click here to register!


 
 
plc storereviewsdownloads
This board is for PLC Related Q&A ONLY. Please DON'T use it for advertising, etc.
 
Try our online PLC Simulator- FREE.  Click here now to try it.

New Here? Please read this important info!!!


Go Back   PLCS.net - Interactive Q & A > Search Forums

Showing results 1 to 25 of 49
Search took 0.02 seconds.
Search: Posts Made By: jmaty23
Forum: LIVE PLC Questions And Answers March 1st, 2018, 12:37 PM
Replies: 3
Views: 854
Posted By jmaty23
Controllogix Controller Workload

Is there a point to where a Controllogix processor receives too many requests for data from external/remote Ethernet devices that it degrades the performance of the processor itself?
Forum: LIVE PLC Questions And Answers May 23rd, 2017, 07:29 AM
Replies: 8
Views: 12,933
Posted By jmaty23
This worked for me as well. Thx!

This worked for me as well. Thx!
Forum: LIVE PLC Questions And Answers March 23rd, 2017, 08:50 AM
Replies: 2
Views: 1,223
Posted By jmaty23
I have a US-485/422 USB to serial converter that...

I have a US-485/422 USB to serial converter that I am trying. Do you know if I can just use a standard Ethernet pass-thru cable to connect to the VFD from the Serial adapter??
Forum: LIVE PLC Questions And Answers March 23rd, 2017, 08:24 AM
Replies: 2
Views: 1,223
Posted By jmaty23
Toshiba VFD Serial Adapter Driver

Has anyone had any success installing the Toshiba USB001Z USB to Serial Adapter to a Windows 10 PC? Is there a Win10 driver available?

I use the adapter to provision Toshiba VSF15 VFDs.
Forum: LIVE PLC Questions And Answers February 27th, 2017, 12:53 PM
Replies: 1
Views: 1,228
Posted By jmaty23
AB Remote Input/Output Communication issue

Can anyone tell me if the COMM and STATUS lights on an Allen-Bradley Remote I/O should be lit solid when it has communication or is it normal for them to be flashing??

The CAT# for the module is...
Forum: LIVE PLC Questions And Answers February 2nd, 2017, 11:19 AM
Replies: 62
Views: 108,769
Posted By jmaty23
Just installed my whole Rockwell software suite...

Just installed my whole Rockwell software suite on Windows 10 Pro (Pheewww....!). All installed and are running fine...

FT Activation Service
RSLogix 5000 v13 thru 20 and Studio5000 v21
CCW 10...
Forum: LIVE PLC Questions And Answers January 13th, 2017, 03:11 PM
Replies: 5
Views: 5,520
Posted By jmaty23
http://search.rockwellautomation.com/search?client...

http://search.rockwellautomation.com/search?client=samplecode&oe=UTF-8&ie=UTF-8&output=xml_no_dtd&proxystylesheet=samplecode&site=sample_code&getfields=*&lang=en&hl=en&sort=date:D:L:d1&wc=200&wc_mc=1&...
Forum: LIVE PLC Questions And Answers September 27th, 2016, 03:00 PM
Replies: 1
Views: 1,612
Posted By jmaty23
Integrate Axis IP Camera feed into FactoryTalk Studio HMI Application

I am looking into the possibility of integrating an existing AXIS IP Camera feed into a FactoryTalk HMI Application. I have downloaded and installed the AXISMediaControl ActiveX control and loaded it...
Forum: LIVE PLC Questions And Answers September 12th, 2016, 08:54 AM
Replies: 2
Views: 1,170
Posted By jmaty23
That's basically as far as I got with the website...

That's basically as far as I got with the website too. I called the sales rep for our area and he basically said that only re-sellers and systems integrator's have access to that information and was...
Forum: LIVE PLC Questions And Answers September 8th, 2016, 01:03 PM
Replies: 2
Views: 1,170
Posted By jmaty23
StruxureWare AS-P Controller - Modbus

I am trying to communicate via Ethernet with a StruxureWare AS-P SmartX Controller. My goal is to use Modbus protocol to monitor when the system goes into alarm.

I am looking for a listing of the...
Forum: LIVE PLC Questions And Answers May 17th, 2016, 09:28 AM
Replies: 3
Views: 1,215
Posted By jmaty23
I tried out the cable that KEP sent me and it...

I tried out the cable that KEP sent me and it worked great. I attached a photo of the cable. The part # is MT5-PC.

I performed the upload using the EasyManager software.

Here is the procedure I...
Forum: LIVE PLC Questions And Answers May 16th, 2016, 05:53 PM
Replies: 3
Views: 1,215
Posted By jmaty23
I ended up contacting KEP on the issue. After we...

I ended up contacting KEP on the issue. After we tried a few troubleshooting steps, the technician ended up sending me the MT5-PC cable. I just received it yesterday. I will being trying it out...
Forum: LIVE PLC Questions And Answers April 26th, 2016, 12:31 PM
Replies: 9
Views: 2,049
Posted By jmaty23
Since all of you had no problems opening the...

Since all of you had no problems opening the file. I decided to download the PVA file that I uploaded to the site and try opening it that way and it worked.

I came to the conclusion that the issue...
Forum: LIVE PLC Questions And Answers April 26th, 2016, 11:22 AM
Replies: 9
Views: 2,049
Posted By jmaty23
AB Panelbuilder32 File wont open

I am wonder if anyone can download the attached Panelbuilder32 PVA file and see if you can get it to open??

I created this file a few years ago and have since reinstalled Panelbuilder on a new...
Forum: LIVE PLC Questions And Answers April 26th, 2016, 08:48 AM
Replies: 3
Views: 1,215
Posted By jmaty23
KEP MMI and EasyBuilder Communication Issue

I am having an issue with uploading the logic file from a KEP MMI-850T Screen. See below for a description of the issue. Can you provide any assistance with this?

I downloaded and installed the...
Forum: LIVE PLC Questions And Answers April 20th, 2016, 02:19 PM
Replies: 3
Views: 4,526
Posted By jmaty23
Is bridging pin 7 and 8 on the pc side required...

Is bridging pin 7 and 8 on the pc side required to connect to a KEP MMI-850T?
Forum: LIVE PLC Questions And Answers February 19th, 2016, 09:08 AM
Replies: 0
Views: 1,542
Posted By jmaty23
Red Lion Crimson 3.0 SQL Sync DSP Server Name Issue

Good Morning All,

I am looking to sync a data log to a SQL server using a RL DSPZR. The sql server that I am trying to connect to is running on a Windows XP computer. The computer name is...
Forum: LIVE PLC Questions And Answers November 24th, 2014, 06:22 PM
Replies: 4
Views: 2,322
Posted By jmaty23
Thanks, I did search RPM in the forum but could...

Thanks, I did search RPM in the forum but could not seem to find anything to assist me. This will get me going. From the post that you linked to, it lists the use of a one-shot relay in the ladder...
Forum: LIVE PLC Questions And Answers November 24th, 2014, 01:06 PM
Replies: 4
Views: 2,322
Posted By jmaty23
RPM Display using AB Micro820

I am looking to detect the RPM/speed of a conveyor belt using a Micro820 processor and a magnetic sensor.

The magnetic sensor would pickup the teeth of a timing sprocket which would be connected...
Forum: LIVE PLC Questions And Answers November 13th, 2014, 01:09 PM
Replies: 4
Views: 6,631
Posted By jmaty23
This is great info thank you. AB did not include...

This is great info thank you. AB did not include an 8-pin serial port on the Micro820, they provided a 5 pin terminal for serial connection for some god awful reason. I will need to make my own cable...
Forum: LIVE PLC Questions And Answers November 12th, 2014, 02:19 PM
Replies: 4
Views: 6,631
Posted By jmaty23
Allen Bradley Micro820 and C200 Panelview HMI

I am looking to connect an Allen Bradley Micro820 processor and an C200 HMI panel via Serial Connection.

Anyone have any suggestions?
Forum: LIVE PLC Questions And Answers September 4th, 2014, 11:33 AM
Replies: 7
Views: 2,128
Posted By jmaty23
Were you able to see the tag value in the Watch...

Were you able to see the tag value in the Watch Window like
I suggested?
Forum: LIVE PLC Questions And Answers September 4th, 2014, 09:01 AM
Replies: 7
Views: 2,128
Posted By jmaty23
What kind of tag is it? Flag Tag , Numeric,...

What kind of tag is it? Flag Tag , Numeric, Basic???

While connected to the DSP via USB, right click on the Data Tag and click "Add to Watch List". Then go to View --> Watch Window ---> Go Online...
Forum: LIVE PLC Questions And Answers September 4th, 2014, 07:11 AM
Replies: 1
Views: 1,041
Posted By jmaty23
Indramat CLC Motion Controller Logic Backup

Top of the mornin to ya,

I recently backed up an Indramat CLC Motion Controller card that controls 6 drives in the loop. I used VisualMotion 7 software to Archive ---> Backup----> Full Backup. I...
Forum: LIVE PLC Questions And Answers August 4th, 2014, 01:04 PM
Replies: 5
Views: 3,275
Posted By jmaty23
I will try to install Windows XP mode to see if...

I will try to install Windows XP mode to see if this works. Thank you!
Showing results 1 to 25 of 49

 