You are not registered yet. Please click here to register!


 
 
plc storereviewsdownloads
This board is for PLC Related Q&A ONLY. Please DON'T use it for advertising, etc.
 
Try our online PLC Simulator- FREE.  Click here now to try it.

---------->>>>>Get FREE PLC Programming Tips

New Here? Please read this important info!!!


Go Back   PLCS.net - Interactive Q & A > Search Forums

Showing results 1 to 25 of 209
Search took 0.06 seconds.
Search: Posts Made By: DBLD99
Forum: LIVE PLC Questions And Answers August 8th, 2018, 10:04 AM
Replies: 103
Views: 5,253
Posted By DBLD99
Work for an Integrator all the plants that we...

Work for an Integrator all the plants that we support are finally up to CLX - L61 is the worst processor we have, and any new plants get the same treatment.



It's really nice :)
Forum: LIVE PLC Questions And Answers June 6th, 2018, 09:00 AM
Replies: 4
Views: 216
Posted By DBLD99
I know this does not help you out now - but would...

I know this does not help you out now - but would highly recommend going to Version 10.


They have a new Distributed Application Manager - and it backs all the servers up HMI / FTD / A&E etc.......
Forum: LIVE PLC Questions And Answers April 24th, 2018, 10:38 AM
Replies: 15
Views: 919
Posted By DBLD99
IMO - We should just not reply to these types of...

IMO - We should just not reply to these types of posts. Obviously, they don't give anything back to the community and they don't read other posts to see how to properly ask questions.
Forum: LIVE PLC Questions And Answers January 23rd, 2018, 02:27 PM
Replies: 19
Views: 1,556
Posted By DBLD99
We have used these for grain piles. Can't...

We have used these for grain piles. Can't remember price though.

https://www.extrongrain.com/wireless-temperature-probes/
Forum: LIVE PLC Questions And Answers December 14th, 2017, 01:55 PM
Replies: 6
Views: 488
Posted By DBLD99
I was assuming you had a remotenode - you did not...

I was assuming you had a remotenode - you did not give enough information for me to believe other wise.

If you say you can Query '\Galaxy!Area - Then goes back to my first post that you need a TOP...
Forum: LIVE PLC Questions And Answers December 14th, 2017, 01:40 PM
Replies: 6
Views: 488
Posted By DBLD99
You have to have the AlarmProvider Server name as...

You have to have the AlarmProvider Server name as well

\\ServerAlarmProviderName\Galaxy!Utility

Then all of the Instances need to be contained under the Utility Area in the Model view for the...
Forum: LIVE PLC Questions And Answers December 14th, 2017, 01:23 PM
Replies: 6
Views: 488
Posted By DBLD99
If your model view is laid out with a "top" area...

If your model view is laid out with a "top" area - ie...

CompanyName
SiteName
Line
etc...

All you have to do is filter your alarms on 'CompanyName' that will give you all the alarms for the...
Forum: LIVE PLC Questions And Answers October 17th, 2017, 09:41 AM
Replies: 23
Views: 727
Posted By DBLD99
Put a AFI in front of the messages.... They will...

Put a AFI in front of the messages.... They will eventually timeout and give you the error message.

This is of course only if your messages instructions are setup with the .err bit or timer to...
Forum: LIVE PLC Questions And Answers July 14th, 2017, 01:59 PM
Replies: 45
Views: 5,024
Posted By DBLD99
One could assume when the OP asked about "Other...

One could assume when the OP asked about "Other Options" with 3 total posts to his name - that he may or may not know ALL OF THE OTHER OPTIONS. Just because you think it was only pertaining to P/C,...
Forum: LIVE PLC Questions And Answers July 14th, 2017, 11:47 AM
Replies: 45
Views: 5,024
Posted By DBLD99
I wasn't going to reply to this thread...

I wasn't going to reply to this thread again...but where in the OP did it say it needed to be time critical.... My post which was not claimed as an "Industry Standard" and was very accurate, besides...
Forum: LIVE PLC Questions And Answers July 13th, 2017, 11:28 AM
Replies: 45
Views: 5,024
Posted By DBLD99
lol - Not sure how to read the last few posts.......

lol - Not sure how to read the last few posts.... I have been doing this for 16 years(So not an amateur) and I use P/C a lot if you can take the line down.... My point was if it is a 24x7 operation....
Forum: LIVE PLC Questions And Answers July 13th, 2017, 07:25 AM
Replies: 45
Views: 5,024
Posted By DBLD99
Depending on Version of 5000 - You can create a...

Depending on Version of 5000 - You can create a UDT with everything you need and a SPARE DINT[xx] and REAL[xx] online. Reason for the spares is once you create it and utilize it with a tag you won't...
Forum: LIVE PLC Questions And Answers May 31st, 2017, 01:04 PM
Replies: 10
Views: 4,761
Posted By DBLD99
Phrog? What do you mean you were not up every...

Phrog? What do you mean you were not up every night for the last 7 years waiting for a reply.....

People really need to look at the dates posted before replying to something. haha
Forum: LIVE PLC Questions And Answers May 9th, 2017, 03:29 PM
Replies: 24
Views: 1,795
Posted By DBLD99
lol....I like some of your options.... one option...

lol....I like some of your options.... one option I always seem to run across while driving the thousands of miles to startups is the guys that mow the interstate/highway grass. It seems like I...
Forum: LIVE PLC Questions And Answers May 9th, 2017, 09:22 AM
Replies: 24
Views: 1,795
Posted By DBLD99
Thanks for all the comments. It helped understand...

Thanks for all the comments. It helped understand the "other" side of the business as well.

I don't think we charge any overtime to the actual customers, as like you said most of our work is a...
Forum: LIVE PLC Questions And Answers May 9th, 2017, 06:49 AM
Replies: 24
Views: 1,795
Posted By DBLD99
Yeah I have taken on a "senior" leadership role...

Yeah I have taken on a "senior" leadership role here. Besides doing all aspects of most projects that come through, I help quote every project that comes through now as well. Only feedback on my...
Forum: LIVE PLC Questions And Answers May 9th, 2017, 06:43 AM
Replies: 24
Views: 1,795
Posted By DBLD99
Yeah I for sure explored doing it as side work....

Yeah I for sure explored doing it as side work. It isn't feasible because it is more than a 3 hour drive to 3 of them and 4-6 hours for the others. The equipment I control is quite expensive too, so...
Forum: LIVE PLC Questions And Answers May 8th, 2017, 07:19 PM
Replies: 24
Views: 1,795
Posted By DBLD99
Thanks for the input - This is the input I was...

Thanks for the input - This is the input I was looking for. What you have said makes total sense, I guess my argument would be, If I am working on ProjectA - then leave for a week or two to help...
Forum: LIVE PLC Questions And Answers May 8th, 2017, 06:22 PM
Replies: 24
Views: 1,795
Posted By DBLD99
Thanks for the replies so far. Obviously the...

Thanks for the replies so far. Obviously the customers that have "followed" me do wait for my time to free up and they are willing to do that to have myself do their work. So the are understanding in...
Forum: LIVE PLC Questions And Answers May 8th, 2017, 03:21 PM
Replies: 24
Views: 1,795
Posted By DBLD99
OT - Compensation above Salary

This is a little OT but I believe this is the best place to ask this question. I have been in system integration for over 16 years, I spent 10 years with one integrator and 6 with my current...
Forum: LIVE PLC Questions And Answers April 20th, 2017, 11:56 AM
Replies: 8
Views: 1,069
Posted By DBLD99
As an Integrator, we had a client that did not...

As an Integrator, we had a client that did not respond when we sent out screenshots during development. After we had the project complete and testing onsite he came to us and said: "I don't know what...
Forum: LIVE PLC Questions And Answers December 6th, 2016, 10:14 AM
Replies: 9
Views: 1,126
Posted By DBLD99
Can't get the file uploaded since it is a .csv ...

Can't get the file uploaded since it is a .csv

I did originally try the SLC/PLC mapping in the CLX but the DAServer just stays in (20:Initializing)
Forum: LIVE PLC Questions And Answers December 6th, 2016, 09:25 AM
Replies: 9
Views: 1,126
Posted By DBLD99
I forgot to mention, I am doing this for...

I forgot to mention, I am doing this for Wonderware. So the galaxy dump puts all of these address in 1 row that is a mile long. A6, B6 ---- all the way to BBX6
Forum: LIVE PLC Questions And Answers December 6th, 2016, 08:22 AM
Replies: 9
Views: 1,126
Posted By DBLD99
I would like some excel gurus to help with this...

I would like some excel gurus to help with this also. I have having the same issue. Can't get excel search and replace to do what I need to do to convert this SLC address to CLX.

Nxx:xx to...
Forum: LIVE PLC Questions And Answers November 22nd, 2016, 08:30 AM
Replies: 6
Views: 1,212
Posted By DBLD99
I have used both the Devicenet and Ethernet...

I have used both the Devicenet and Ethernet modules from Turck and A/B - both work good. Our A/B pricing is actually better then Turcks at the moment so we have been using A/B.

Never had issue...
Showing results 1 to 25 of 209

 
Forum Jump