Search: Posts Made By: Marc
Forum: LIVE PLC Questions And Answers July 3rd, 2014, 12:51 PM
Replies: 6
Views: 1,043
Posted By Marc
Also note that your power supply is way too small...

Also note that your power supply is way too small for your I/O count.

Marc
Forum: LIVE PLC Questions And Answers June 5th, 2014, 09:19 AM
Replies: 5
Views: 2,297
Posted By Marc
Unsaint, The order in which you described...

Unsaint,

The order in which you described the events indicates you didn't go online until after you looked at the Status file. You may have been looking at the status bits from the last time...
Forum: LIVE PLC Questions And Answers May 13th, 2014, 11:09 AM
Replies: 10
Views: 1,029
Posted By Marc
Filename is *.CHA There are 3 ways to...

Filename is *.CHA

There are 3 ways to program these, online with a browser
Using Panel view component design station or
with Connected components Workbench software.

What version are you...
Forum: LIVE PLC Questions And Answers March 28th, 2014, 02:00 PM
Replies: 14
Views: 1,943
Posted By Marc
Any time! That's why we are here Marc

Any time!

That's why we are here

Marc
Forum: LIVE PLC Questions And Answers March 28th, 2014, 12:44 PM
Replies: 14
Views: 1,943
Posted By Marc
Unsure, WOW 9701-VWSTMENE ...

Unsure, WOW

9701-VWSTMENE

9701-VWSTMENE FactoryTalk View Studio for Machine Edition


Marc
Forum: LIVE PLC Questions And Answers December 17th, 2013, 12:57 PM
Replies: 0
Views: 562
Posted By Marc
Re-size PVComponent Application

Hi all,

I have a .CHA file that was written for a 6 Inch monochrome Panel View Component. I am trying to load it into a 4 Inch color PV Component screen and it looks fine, just gives an error on...
Forum: LIVE PLC Questions And Answers December 5th, 2012, 11:01 AM
Replies: 14
Views: 9,832
Posted By Marc
One other thing I remember was to tick the Cache...

One other thing I remember was to tick the Cache connection box on the communication tab of the instruction configuration popup.

Marc
Forum: LIVE PLC Questions And Answers December 5th, 2012, 10:58 AM
Replies: 14
Views: 9,832
Posted By Marc
When I did this a little while back, I had better...

When I did this a little while back, I had better results using the controller name name instead of the ethernet path. Check Module properties and just enter the NAME from the general tab in your...
Forum: LIVE PLC Questions And Answers December 5th, 2012, 09:44 AM
Replies: 11
Views: 8,728
Posted By Marc
Hi Paul, I ran into the same issue the...

Hi Paul,

I ran into the same issue the other day. I downloaded FTView 6.1 and it told me it would not work with EVRSI activation. So I only installed the Transfer Utility from 6.1 and kept...
Forum: LIVE PLC Questions And Answers November 18th, 2012, 11:18 AM
Replies: 3
Views: 711
Posted By Marc
Hi Operaghost, I did in fact drill down to...

Hi Operaghost,

I did in fact drill down to the device under the RSLinx Enterprise tab and the ethernet driver.

I managed to get to the RA website and download the V 6.1 of FTView Studio. It...
Forum: LIVE PLC Questions And Answers November 18th, 2012, 10:35 AM
Replies: 3
Views: 711
Posted By Marc
PV Plus 6

Hi Everyone,

I have a Panelview Plus 6 1000 which I am attempting to program. I have created the program but when I try to transfer the .MER file, the transfer utility says "The destination...
Forum: LIVE PLC Questions And Answers August 14th, 2012, 07:04 AM
Replies: 6
Views: 1,813
Posted By Marc
RSS is Rslogix 500 not 5000 APA is factory talk...

RSS is Rslogix 500 not 5000
APA is factory talk view (open with Application manager) as they are an archive of the .MER (M E Runtime) files

Marc
Forum: LIVE PLC Questions And Answers February 11th, 2011, 10:00 AM
Replies: 2
Views: 993
Posted By Marc
Hi Badger, It is there and it is 1kb =...

Hi Badger,

It is there and it is 1kb = empty. It's weird since I have been using GXDEV for over 10 years and have never seen this happen.

Looks like I'll have to start documenting the file...
Forum: LIVE PLC Questions And Answers February 11th, 2011, 08:09 AM
Replies: 89
Views: 15,934
Posted By Marc
Things you don't want to hear on a start-up ...

Things you don't want to hear on a start-up

Sudden Dead Silence :)

Marc
Forum: LIVE PLC Questions And Answers February 11th, 2011, 06:30 AM
Replies: 2
Views: 993
Posted By Marc
GX Developer Comments

Hi All,

We had a funny thing happen this morning in GX Developer. I opened a program file and all of the comments were gone. Very strange, has this ever happened to any of you and were you able...
Forum: LIVE PLC Questions And Answers December 30th, 2010, 06:16 AM
Replies: 3
Views: 1,923
Posted By Marc
Shivam, I'll second Dave's (504Bloke)...

Shivam,

I'll second Dave's (504Bloke) suggestion.

Mark's (geniusintraining) stuff is top notch and he is a pleaseure to work with.

Marc
Forum: LIVE PLC Questions And Answers December 22nd, 2010, 05:56 AM
Replies: 8
Views: 1,752
Posted By Marc
DOH! Sorry to hear that. Marc

DOH!

Sorry to hear that.

Marc
Forum: LIVE PLC Questions And Answers November 19th, 2010, 06:24 AM
Replies: 8
Views: 1,845
Posted By Marc
Hi Again, Yes, at least my E6500 has both...

Hi Again,

Yes, at least my E6500 has both express and PCMCIA slots.

I always explain to the IT folks that this is a tool used for making money. It isnt for email and MSword. Besides, tha...
Forum: LIVE PLC Questions And Answers November 19th, 2010, 06:02 AM
Replies: 8
Views: 1,845
Posted By Marc
Hi Jesper, FYI I have a Dell Latitude E6500...

Hi Jesper,

FYI I have a Dell Latitude E6500 with a fully functional PCMCIA slot that works just fine with my 1784-PCMK series B. It does not have a serial port so I got the 9300-USBS for DF1.
...
Forum: LIVE PLC Questions And Answers November 18th, 2010, 05:32 AM
Replies: 4
Views: 2,693
Posted By Marc
Hi Matthew, In the RSLogix500 project tree,...

Hi Matthew,

In the RSLogix500 project tree, open Controller, controller properties, function files. Got to the RTC tab and click Set Date and Time. The time will sychonize with your prograaming...
Forum: LIVE PLC Questions And Answers September 3rd, 2010, 08:30 AM
Replies: 8
Views: 1,612
Posted By Marc
Same here, our vendor must have supplied Rockwell...

Same here, our vendor must have supplied Rockwell with a list of our P.O.s that included 193-E purchases, and it was a bunch.

Don't have a plan on how to address as of yet.

Marc
Forum: LIVE PLC Questions And Answers September 2nd, 2010, 08:30 AM
Replies: 2
Views: 1,467
Posted By Marc
Hi Pranav Try Here ...

Hi Pranav

Try Here

http://www.rockwellautomation.com/support/pccards/

Marc
Forum: LIVE PLC Questions And Answers September 2nd, 2010, 08:21 AM
Replies: 8
Views: 1,612
Posted By Marc
Product Notice from Rockwell

Hi The Plc Kid,

This is a copy of what we recieved from Rockwell

Marc
Forum: LIVE PLC Questions And Answers September 1st, 2010, 01:29 PM
Replies: 8
Views: 1,612
Posted By Marc
AB 193-E series overload issues

Hi everyone,

I just recieved an Important Product Service Notice from Rockwell Automation regarding the 193-E series overloads. Someone posted a question on another thread regarding a different...
Forum: LIVE PLC Questions And Answers September 1st, 2010, 01:23 PM
Replies: 22
Views: 3,752
Posted By Marc
Hi Ken, I just got a product service notice...

Hi Ken,

I just got a product service notice on 193-E series listing 50+ overloads we have purchased and thats only up till April, we have probably purchased another 50 since then!

I'll start...