Search: Posts Made By: alielectrical
Forum: LIVE PLC Questions And Answers April 26th, 2016, 05:08 AM
Replies: 12
Views: 43,005
Posted By alielectrical
Dear Sir, There is no harm in getting a...

Dear Sir,
There is no harm in getting a chuckle, but would be better if kept to ones self.
KalleOlsen's post is a good example of sarcasm plus guidance and support.
One should look at the point...
Forum: LIVE PLC Questions And Answers July 15th, 2014, 09:27 AM
Replies: 4
Views: 864
Posted By alielectrical
S7 300 Memory Reset

Visit the following site for manual, .
http://manuali.eltex.biz/Manuali_Siemens/S73bhb_e.pdf (http://manuali.eltex.biz/Manuali_Siemens/S73bhb_e.pdf)

Page 132 of the manual gives graphical version...
Forum: LIVE PLC Questions And Answers July 15th, 2014, 09:07 AM
Replies: 4
Views: 864
Posted By alielectrical
S7 300 Memory Reset

Page 132 of the manual gives graphical version of reset


Resetting the CPU Memory Using the Mode Selector
To reset the CPU memory using the mode selector , do the following (also see...
Forum: LIVE PLC Questions And Answers July 14th, 2014, 09:51 AM
Replies: 4
Views: 864
Posted By alielectrical
Visit the following site for manual, . ...

Visit the following site for manual, .
http://manuali.eltex.biz/Manuali_Siemens/S73bhb_e.pdf (http://manuali.eltex.biz/Manuali_Siemens/S73bhb_e.pdf)

Page 131gives following description, page 132...
Forum: LIVE PLC Questions And Answers July 14th, 2014, 06:49 AM
Replies: 18
Views: 26,176
Posted By alielectrical
Sohail, How did you solve the problem? Was it...

Sohail,
How did you solve the problem?
Was it the 50/60Hz dip switch?
Regards,
ali
Forum: LIVE PLC Questions And Answers October 7th, 2013, 11:59 AM
Replies: 0
Views: 423
Posted By alielectrical
505 plc + profibus

We have a 505 program with profibus.

We would like to add some more drives, but have lost the original comprofibus files.

How can we retrieve the profibus configuration from the original...
Forum: LIVE PLC Questions And Answers July 19th, 2013, 03:35 PM
Replies: 6
Views: 1,272
Posted By alielectrical
Blue Fox, I humbly beg to differ from your...

Blue Fox,

I humbly beg to differ from your comment that people are happy to help others with no benefit to themselves.
Believe it or not they feel fulfilled and content when they see that not...
Forum: LIVE PLC Questions And Answers November 20th, 2012, 04:04 PM
Replies: 5
Views: 3,292
Posted By alielectrical
Dear sir, I would like to add that at times,...

Dear sir,

I would like to add that at times, actually many. times i was stumbled while learning new functions and since i was self learning i had difficulty understanding the manual and like...
Forum: LIVE PLC Questions And Answers August 6th, 2012, 11:29 PM
Replies: 3
Views: 1,522
Posted By alielectrical
I have another site, ...

I have another site, http://www.3s-software.com/index.shtml?en_quick_start_prog

Hope this helps,
ali
Forum: LIVE PLC Questions And Answers August 6th, 2012, 11:22 PM
Replies: 3
Views: 1,522
Posted By alielectrical
Dear Bhautik, You can google Codesys or go...

Dear Bhautik,

You can google Codesys or go to the site http://www.3s-software.com/index.shtml?en_download and download the software alongwith tutorials.
Also you can go on WAGO site and download...
Forum: LIVE PLC Questions And Answers June 28th, 2012, 06:07 AM
Replies: 12
Views: 2,011
Posted By alielectrical
Misbah, Pls inform what HMI program you are...

Misbah,

Pls inform what HMI program you are using as well as the type of plc and hmi.
Is it possible to monitor the program?
Forum: LIVE PLC Questions And Answers June 27th, 2012, 05:57 AM
Replies: 1
Views: 562
Posted By alielectrical
Gaurang, I presume that your software is not...

Gaurang,
I presume that your software is not latest, What is the version of your software?
Can you verify the version that the program was made with.
Regards,
ali
Forum: LIVE PLC Questions And Answers December 13th, 2011, 06:48 AM
Replies: 19
Views: 10,553
Posted By alielectrical
PacDrive Diagnostic for troubleshooting

Dear,
You need ELAU software EPAS4 version 22, but if your program is using version 24, then you need version 24 to log on.
This is required if you want to modify the program.

But if you want...
Forum: LIVE PLC Questions And Answers December 7th, 2011, 08:28 PM
Replies: 19
Views: 10,553
Posted By alielectrical
Dear Elsawy Zedan, How can I help you...

Dear Elsawy Zedan,

How can I help you regarding your new filling machine with two servo motors controlled by elau c400?

Regards,
ali
Forum: LIVE PLC Questions And Answers November 23rd, 2011, 08:55 PM
Replies: 19
Views: 10,553
Posted By alielectrical
Epas4

Dear Rexythe1,

If you want information about EPAS4 or programming ELAU C400 drives, contact me.

Yours truly,
ali.
Forum: LIVE PLC Questions And Answers September 1st, 2011, 08:46 PM
Replies: 12
Views: 4,088
Posted By alielectrical
Shooter, I want to use Codesys and Elau...

Shooter,

I want to use Codesys and Elau servomotors.
How do I configure servomotors in Codesys?
Thanks.
Forum: LIVE PLC Questions And Answers August 29th, 2011, 02:02 PM
Replies: 12
Views: 4,088
Posted By alielectrical
Thanks

Shooter,
Thanks for the information, I was unaware of this, as I am a novice in Elau, and am still learning.
Forum: LIVE PLC Questions And Answers August 24th, 2011, 06:00 AM
Replies: 12
Views: 4,088
Posted By alielectrical
Dear 123jaop, I attach the screenshot of my...

Dear 123jaop,

I attach the screenshot of my problem.

But then I realised that I was saving the file in default drive, D:, which was CDRom drive without a cd.Hence, the file was not saved...
Forum: LIVE PLC Questions And Answers August 22nd, 2011, 06:07 AM
Replies: 12
Views: 4,088
Posted By alielectrical
Dear 123jaop, While uploading the files, do you...

Dear 123jaop,
While uploading the files, do you get the messages, uploading xxxxx bytes etc.
Becasue I had the problem, files would upload and termiante without any message and would say that...
Forum: LIVE PLC Questions And Answers August 16th, 2011, 09:57 PM
Replies: 12
Views: 4,088
Posted By alielectrical
Dear 123jaop, You can upload the program...

Dear 123jaop,

You can upload the program from your Max-4 controller if you have EPAS4 program.
To upload by RS232, you should have RS232 cable only, while to upload with Ethernet, you should...
Forum: LIVE PLC Questions And Answers November 17th, 2008, 01:17 AM
Replies: 4
Mmc
Views: 813
Posted By alielectrical
Osama, From what I understand, You need not...

Osama,

From what I understand, You need not have a new MMC to modify the program.

What I do is Upload the existing program in a new project and name it say, "Proj1Upload081117".

Then...
Forum: LIVE PLC Questions And Answers October 15th, 2008, 09:41 AM
Replies: 8
Views: 1,035
Posted By alielectrical
Dear, In toronto, we have 1 888 303 3353...

Dear,

In toronto, we have 1 888 303 3353 Siemens help desk.

Or you can call Shawn Dyson from Ontor Electrical 416 781 5286 his extension is 2239.

In case you are in toronto city I may help...
Forum: LIVE PLC Questions And Answers July 22nd, 2008, 04:54 AM
Replies: 31
Views: 4,457
Posted By alielectrical
Shift application

Dear Aravind,

I have used shift, shift bit left to control and monitor the movement of bottles.
Everytime a bottle moves a pulse is generated which shifts the position of that bottle, and if it...
Forum: LIVE PLC Questions And Answers April 11th, 2008, 11:12 PM
Replies: 6
Views: 2,768
Posted By alielectrical
Dear jstolaruk, I am sorry if I was not very...

Dear jstolaruk,
I am sorry if I was not very clear. But the system is working normally ok.
We only have this problem when 24dc to coupler is switched off and then on.
Once we disconnect the...
Forum: LIVE PLC Questions And Answers April 11th, 2008, 02:11 AM
Replies: 6
Views: 2,768
Posted By alielectrical
DP/DP Coupler

DP/DP Coupler
We have S7 300 DP coupled with 505, using Siemens DP/DP coupler.
When we turn off the 24 dc supply to DP/DP coupler and then switch on, DP/DP coupler shows fault on 505 side.Led...
Showing results 1 to 25 of 47

 