Forum: LIVE PLC Questions And Answers
February 23rd, 2021, 09:33 AM
|
Replies: 8
Views: 410
Not and OEM but an Integrator...
Ignition is...
Not and OEM but an Integrator...
Ignition is definitely a factory automation solution more so than an OEM solution. However they have introduced the "Edge" variation of Ignition to help address...
|
Forum: LIVE PLC Questions And Answers
February 22nd, 2021, 05:20 PM
|
Replies: 9
Views: 496
|
Forum: LIVE PLC Questions And Answers
February 14th, 2021, 07:14 PM
|
Replies: 27
Views: 3,120
|
Forum: LIVE PLC Questions And Answers
February 13th, 2021, 09:00 PM
|
Replies: 8
Views: 644
|
Forum: LIVE PLC Questions And Answers
February 12th, 2021, 11:26 PM
|
Replies: 8
Views: 644
Direct for me, for the most part. In my AOI/UDT...
Direct for me, for the most part. In my AOI/UDT definitions (AB guy here) I might have dedicated tags more so for clarity. "ScadaCmd" vs "ProgCmd" to differentiate were the command originated. I may...
|
Forum: LIVE PLC Questions And Answers
January 22nd, 2021, 09:57 AM
|
Replies: 2
Views: 339
I just write the integer value to the PLC tag....
I just write the integer value to the PLC tag. Since the PLC tag itself sets the style there isn't anything you should need to consider in VBA.
For example, if I want the PLC tag to have a value...
|
Forum: LIVE PLC Questions And Answers
January 15th, 2021, 08:14 AM
|
Replies: 32
Views: 2,244
|
Forum: LIVE PLC Questions And Answers
January 14th, 2021, 09:39 PM
|
Replies: 32
Views: 2,244
Ah...no.
Diagrams like this should...
Ah...no.
Diagrams like this should communicate to non-programmers what the expected operation of the equipment/process will be. It should be used as an engineering document to tell others how to...
|
Forum: LIVE PLC Questions And Answers
January 14th, 2021, 09:09 PM
|
Replies: 8
Views: 650
|
Forum: LIVE PLC Questions And Answers
January 14th, 2021, 09:08 PM
|
Replies: 8
Views: 650
|
Forum: LIVE PLC Questions And Answers
December 23rd, 2020, 12:18 AM
|
Replies: 4
Views: 737
|
Forum: LIVE PLC Questions And Answers
December 11th, 2020, 08:43 AM
|
Replies: 22
Views: 1,762
Weren't we suppose to see soft PLCs take over...
Weren't we suppose to see soft PLCs take over since 2000ish? The premise of it being more feasible now due to virtualization, docker, "maturation of Linux" seems to only complicate matters.
...
|
Forum: LIVE PLC Questions And Answers
December 2nd, 2020, 03:29 PM
|
Replies: 13
Views: 1,037
|
Forum: LIVE PLC Questions And Answers
December 1st, 2020, 03:47 PM
|
Replies: 9
Views: 1,061
16:10 died out quickly, which was really...
16:10 died out quickly, which was really disappointing. 16:9 is for TV, from a manufacturing process of the glass I don't see this changing. Your next hurdle is 4K and dealing with high DPI. Although...
|
Forum: LIVE PLC Questions And Answers
November 25th, 2020, 09:59 PM
|
Replies: 8
Views: 695
It's not obvious? :lolis:
...
It's not obvious? :lolis:
Understandable, I've been there.
Best advice I can give is to let go of old habits, they will inhibit your creative juices when it comes to what you can do with...
|
Forum: LIVE PLC Questions And Answers
November 25th, 2020, 06:44 PM
|
Replies: 8
Views: 695
Some further thought, given you are using...
Some further thought, given you are using Ignition you should try and drop some antiquated habits.
Within Ignition, create a useful UDT that's a bit more readable:
Name: ConveyorControl
...
|
Forum: LIVE PLC Questions And Answers
November 25th, 2020, 06:22 PM
|
Replies: 8
Views: 695
This is something I had to get past in my...
This is something I had to get past in my Ignition early days.
If, you just need read only then you can use the getBit() expression against the DINT tag, makes it pretty simple to replicate...
|
Forum: LIVE PLC Questions And Answers
November 16th, 2020, 05:58 PM
|
Replies: 15
Views: 1,246
There was a time where I vividly remember...
There was a time where I vividly remember Rockwell support telling me to install newest --> oldest. IIRC this was round v20/windows 7 compatibility. Install v20 first then go backwards. :huh:
|
Forum: LIVE PLC Questions And Answers
October 3rd, 2020, 09:16 PM
|
Replies: 24
Views: 3,464
|
Forum: LIVE PLC Questions And Answers
September 25th, 2020, 08:53 PM
|
Replies: 5
Views: 909
|
Forum: LIVE PLC Questions And Answers
September 23rd, 2020, 07:12 PM
|
Replies: 5
Views: 693
TP-Link Omada AC1750...
TP-Link Omada AC1750 (https://www.amazon.com/gp/product/B07NMZR3F1/ref=ppx_yo_dt_b_asin_title_o03_s00?ie=UTF8&psc=1)
Been using this for a year now commissioning a plant, range is crazy for the...
|
Forum: LIVE PLC Questions And Answers
September 17th, 2020, 09:59 PM
|
Replies: 48
Views: 5,890
|
Forum: LIVE PLC Questions And Answers
September 11th, 2020, 08:40 AM
|
Replies: 2
Views: 872
|
Forum: LIVE PLC Questions And Answers
September 8th, 2020, 02:28 PM
|
Replies: 11
Views: 1,327
You should look into creating a sorting...
You should look into creating a sorting algorithm. I've previously created an Insertion sort based of an example I found using pascal. Close enough to ST to serve as a guide.
In my exercise, I...
|
Forum: LIVE PLC Questions And Answers
September 3rd, 2020, 09:18 AM
|
Replies: 11
Views: 1,253
|