Search: Posts Made By: blawrenz
Forum: LIVE PLC Questions And Answers November 9th, 2017, 10:33 AM
Replies: 5
Views: 654
Posted By blawrenz
I checked the list pricing on an L71 vs an L81e...

I checked the list pricing on an L71 vs an L81e and the list price cost difference is $80. Seems to me that it is probably a no brainer.
Forum: LIVE PLC Questions And Answers November 9th, 2017, 10:11 AM
Replies: 5
Views: 654
Posted By blawrenz
CtrlLgx L8x vs L7x

Hello All,
I am looking at specifying a new Control Logix project and was wondering if I could get some feedback on the new Rockwell Automation L8x series of processors vs the L7x series of...
Forum: LIVE PLC Questions And Answers July 24th, 2017, 08:50 AM
Replies: 9
Views: 738
Posted By blawrenz
Thoughts on embedding AOI's inside AOI's

:hmmm::hmmm:I have recently been running across more and more Control Logix programs from vendors that are embedding AOI's inside of other AOI's. I have run into one instance where it was three...
Forum: LIVE PLC Questions And Answers November 30th, 2016, 02:40 PM
Replies: 1
Views: 700
Posted By blawrenz
Question What HMI software does this belong to?

Hi,
I received a backup of an old HMI application from a client. I am unsure as to what graphics package was used to configure this application. It is at least 10 years old as the back-up was...
Forum: LIVE PLC Questions And Answers July 28th, 2016, 05:31 PM
Replies: 4
Views: 1,063
Posted By blawrenz
Thanks TWS, I reviewed that document and found...

Thanks TWS,
I reviewed that document and found that it showed that fiber could be utilized. When I initially looked at it I did not notice that it said you had to use the 1783-ETAP device. So, I...
Forum: LIVE PLC Questions And Answers July 28th, 2016, 09:11 AM
Replies: 4
Views: 1,063
Posted By blawrenz
Will DLR work with Fiber

I was wondering if anyone has any experience with setting up a Rockwell Automation DLR network and utilizing fiber between some of the nodes?
I am working on the layout of a new system that utilizes...
Forum: LIVE PLC Questions And Answers June 19th, 2015, 08:42 AM
Replies: 1
Views: 627
Posted By blawrenz
Dog Cimplicity HMI Tag Definition

I have a question related to the tag definition of a Cimplicity HMI tag. I have an existing application in which I have csv export of the tag DB and I have a handfull of tags that have some...
Forum: LIVE PLC Questions And Answers March 22nd, 2011, 10:18 AM
Replies: 3
Views: 5,711
Posted By blawrenz
Thanks Val!! FYI for anyone interested. ...

Thanks Val!!

FYI for anyone interested. Rockwell indicated to me that RSLinx 2.57 has an automatic USB driver that once it is plugged in it will automatically see the processor. They also...
Forum: LIVE PLC Questions And Answers March 22nd, 2011, 09:34 AM
Replies: 3
Views: 5,711
Posted By blawrenz
AB 1756-L74 RSLinx Driver

I am using one of the new Rockwell 1756-L74 processors. The processor does not have the RS-232 port that I am used to on the older processors, it has a square USB port. Does anyone know what driver...
Forum: LIVE PLC Questions And Answers November 9th, 2006, 07:07 AM
Replies: 23
Views: 2,584
Posted By blawrenz
Dave, Are you just looking to mark this...

Dave,

Are you just looking to mark this part as good or bad?? If so you could use a shift register for this, (BSL or BSR). If each part has more information than good or bad associated with it...
Forum: LIVE PLC Questions And Answers November 7th, 2006, 07:05 AM
Replies: 4
Views: 1,900
Posted By blawrenz
Kenschunk, Thanks for the feedback! Yes I...

Kenschunk,

Thanks for the feedback! Yes I will be doing a BLKM to the 4x register as those are the registers that the DCS system will be looking at.

As far as the software, I would like to...
Forum: LIVE PLC Questions And Answers November 6th, 2006, 09:42 AM
Replies: 4
Views: 1,900
Posted By blawrenz
Talking Quantum 140ATI03000 Thermocouple Module

I read a couple of threads in regards to this module and have questions about this module and since I cannot seem to find the documentation on the Modicon website I thought I would ask some questions...
Forum: LIVE PLC Questions And Answers November 3rd, 2006, 06:46 AM
Replies: 2
Views: 2,588
Posted By blawrenz
Brian, I checked out that thread and tried...

Brian,

I checked out that thread and tried the things that had been posted and was unable to get what I wanted. I am having the opposite problem that you had, the text is so small that you can't...
Forum: LIVE PLC Questions And Answers November 2nd, 2006, 07:07 AM
Replies: 2
Views: 2,588
Posted By blawrenz
Talking ProWORX 32

I am using ProWORX 32 version 2.0 for a project that I am working on. When I go to print my networks out from the report generator. I am unable to read the comments and addresses on the print-out. I...
Forum: LIVE PLC Questions And Answers August 14th, 2006, 12:32 PM
Replies: 6
Views: 8,377
Posted By blawrenz
Kevin, Thanks that makes me feel better knowing...

Kevin,
Thanks that makes me feel better knowing that you have had success with this type of upgrade.

A follow-up to the previous comments. I contacted Taylor Software in Canada and they did say...
Forum: LIVE PLC Questions And Answers August 10th, 2006, 05:29 PM
Replies: 6
Views: 8,377
Posted By blawrenz
Lancie1, Thanks for the feedback, I found a...

Lancie1,
Thanks for the feedback, I found a website for them but was not sure if it was the same Taylor. My understanding was that Taylor had gotten sold to Total Control and then Total Control was...
Forum: LIVE PLC Questions And Answers August 9th, 2006, 04:31 PM
Replies: 6
Views: 8,377
Posted By blawrenz
Taylor Industrial Software

I am working with a customer that has a control system that is using a Wonderware like software called Taylor Industrial Software that is being used as an HMI interface to a Modicon 984 PLC.

They...
Forum: LIVE PLC Questions And Answers July 27th, 2006, 12:32 PM
Replies: 2
Views: 805
Posted By blawrenz
RSLogix 500 is for SLC and Micrologix Processors....

RSLogix 500 is for SLC and Micrologix Processors.
RSLogix 5 is for PLC 5 Processors.
Forum: LIVE PLC Questions And Answers July 14th, 2006, 07:10 AM
Replies: 4
Views: 1,386
Posted By blawrenz
Grambrinus, This is a customer specification, we...

Grambrinus, This is a customer specification, we are upgrading some old existing systems and they want to bring everything up to the same PLC and still be able to utilize their existing software in...
Forum: LIVE PLC Questions And Answers July 13th, 2006, 09:50 AM
Replies: 4
Views: 1,386
Posted By blawrenz
Quantum Memory Allocation

I am new to Modicon Quantum processors and have a couple of questions if anyone can help I would appreciate it.

PLC Model is a Quantum 140 CPU 113 02
Programming Software will be ProWORX Nxt
...