Forum: LIVE PLC Questions And Answers May 18th, 2005, 04:14 AM
Replies: 4
Views: 3,029
Posted By netvisor
AHH the solution

Well after two days of frustration our IT guys finally found the problem.As this was a server in our server room we where using remote desktop to set it up.Rslinks doesnt like remote desktop at all,...
Forum: LIVE PLC Questions And Answers May 17th, 2005, 06:12 AM
Replies: 4
Views: 3,029
Posted By netvisor
im using version 2.43 looks like we might need to...

im using version 2.43 looks like we might need to go back to 2000!!!!!
Forum: LIVE PLC Questions And Answers May 17th, 2005, 04:44 AM
Replies: 4
Views: 3,029
Posted By netvisor
rslinx wont run on server 2003

Hi all,
I having an issue at the moment trying to get rslinks oem running on a windows server 2003 machine.The install all went fine no errors but the application just wont run.The only way I can...
Forum: LIVE PLC Questions And Answers June 7th, 2004, 06:23 PM
Replies: 12
Views: 3,368
Posted By netvisor
sounds to me like your inputs aren't picking up a...

sounds to me like your inputs aren't picking up a correct reference point to work correctly????????? I would say that the inputs would rectify the the applied voltage internally before sampling them...
Forum: LIVE PLC Questions And Answers March 30th, 2004, 09:14 PM
Replies: 7
Views: 2,569
Posted By netvisor
You Poor person

I have all the software for programming these horrible, horrible plcs you better bring plenty of panadol with you. Pm me.
Forum: LIVE PLC Questions And Answers January 30th, 2004, 10:38 PM
Replies: 5
Views: 1,579
Posted By netvisor
maybe try this

It may help, try reducing the carrier frequency of the variable speed drives it has worked wonders for vsd noise related issues for me, lower carrer frequencies tend to induce less emf into...
Forum: LIVE PLC Questions And Answers January 21st, 2004, 01:36 AM
Replies: 6
Views: 1,410
Posted By netvisor
A ml1000 is an micrologix 1000 an ab plc. I agree...

A ml1000 is an micrologix 1000 an ab plc. I agree i would do the same as tcig just start the timer from the down signal and reset it it from the down sensor if it doesnt make before the timer is...
Forum: LIVE PLC Questions And Answers January 17th, 2004, 03:53 PM
Replies: 4
Views: 4,020
Posted By netvisor
modbus plus ethernet bridge

H all,
At the moment our modicon modbus plus network consists of 6 of 984 processors, two plc programming workstations and two Citect servers.The two workstations and two servers have SA-85 cards...
Forum: LIVE PLC Questions And Answers January 14th, 2004, 03:42 PM
Replies: 10
Views: 2,300
Posted By netvisor
SOURCE/SINK

VERY SIMPLE:
CURRENT SOURCING OR PNP SENSORS SOURCE OR SUPPLY CURRENT WHICH MEANS THE OUTPUT BECOMES A POSITIVE WHEN ITS ON AND FLOAT WHEN THE SENSOR IS OFF SO YOU WOULD CONNECT YOUR LOAD BETWEEN...
Forum: LIVE PLC Questions And Answers January 13th, 2004, 02:18 AM
Replies: 4
Views: 1,484
Posted By netvisor
why not just

Why dont you just use a voltage divider resistor net work?
Forum: LIVE PLC Questions And Answers January 11th, 2004, 04:42 PM
Replies: 20
Views: 3,832
Posted By netvisor
not worth it

Unless you already had an older version of rs logix its not worth purchasing a version w/out the activation as mday says you probably wont have any luckwith ab as you would need to be in support any...
Forum: LIVE PLC Questions And Answers January 8th, 2004, 12:13 AM
Replies: 39
Views: 7,768
Posted By netvisor
I have managed to move my activation successfully...

I have managed to move my activation successfully to a usb memory stick.Ater much of this though-----> bonkhead
btw you can move from the hard disk to a floppy under win 95 I am certain of this as...
Forum: LIVE PLC Questions And Answers December 30th, 2003, 08:55 PM
Replies: 5
Views: 4,018
Posted By netvisor
yes the pj.ini files are the ones that seem to...

yes the pj.ini files are the ones that seem to confuse me the most
Forum: LIVE PLC Questions And Answers December 30th, 2003, 04:44 AM
Replies: 5
Views: 4,018
Posted By netvisor
thanks guys

So I take it if I need to do a restore I just point my step 5 software to the location of the program file and the documentation files and thats it????
What about project files ????how do they...
Forum: LIVE PLC Questions And Answers December 28th, 2003, 04:48 AM
Replies: 5
Views: 4,018
Posted By netvisor
Question step 5 for DOS program files Structure

Hi all,
Just wondering if any step 5 " experts" out there could take the the time to explain the files that pertain to a plc program and how they interrelate to each other when using step 5 for...
Forum: LIVE PLC Questions And Answers December 7th, 2003, 12:05 AM
Replies: 11
Views: 2,091
Posted By netvisor
Gday, we use the small "Oriental" branded...

Gday,
we use the small "Oriental" branded motors for all of our checkweigher conveyors.They are essentially a splitphase single phase 110v motor.The controllers for these motors are supplied with...
Forum: LIVE PLC Questions And Answers December 6th, 2003, 11:54 PM
Replies: 9
Views: 2,599
Posted By netvisor
I would have absolutely no qualms with doing this...

I would have absolutely no qualms with doing this at all.The ones you really wanna stay away from are the ac signals particularly higher voltage ones and seeing how it is such a short run I reckon...
Forum: LIVE PLC Questions And Answers December 3rd, 2003, 03:56 PM
Replies: 14
Views: 1,754
Posted By netvisor
IT DOES!!!!!!!!!!!!!!!

IT DOES!!!!!!!!!!!!!!!
Forum: LIVE PLC Questions And Answers November 18th, 2003, 07:21 PM
Replies: 7
Views: 4,117
Posted By netvisor
either or doesnt really matter but to keep things...

either or doesnt really matter but to keep things simple i would just use a single 24vdc charger cheers tom
Forum: LIVE PLC Questions And Answers November 15th, 2003, 02:06 PM
Replies: 7
Views: 4,117
Posted By netvisor
I agree just use two 12 volt batteries in series,...

I agree just use two 12 volt batteries in series, use the negative side for both negatives and pick up off the common point between the two batteries for 12v and pick up off the other side for 24v......
Forum: LIVE PLC Questions And Answers November 8th, 2003, 04:41 AM
Replies: 1
Views: 1,700
Posted By netvisor
dh+ ethernet coms

Hi all,
Our network has a micrologix 1200 conected by a 1761-net-eni to ethernet, also on this same ethernet network lives a control logix processor which also has a dh+ network attached to it...
Forum: LIVE PLC Questions And Answers November 3rd, 2003, 12:45 PM
Replies: 2
Views: 1,573
Posted By netvisor
thanks

Thanks Ken,
Actually the 1761 net eni is about a third of the price of the firmware uprade......ideally the firmware upgrade would be the tidiest way to do it but its way too expensive, as for the...
Forum: LIVE PLC Questions And Answers November 2nd, 2003, 07:38 PM
Replies: 2
Views: 1,573
Posted By netvisor
plc5 coms issue

hi all trying to get a plc5 to talk to a micrologix 1200 AB says I need a firmware upgrade to allow multihop messaging in the 5 to allow it to talk with the 1761 eni net(DF1- Ethernet...