Search: Posts Made By: dmroeder
Forum: LIVE PLC Questions And Answers Today, 11:44 AM
Replies: 10
Views: 135
Posted By dmroeder
What version are you using? v24 is kinda buggy...

What version are you using? v24 is kinda buggy for me. Occasionally, the value field is grayed out on the monitor tag window, I end up having to close the program and open it again. Maybe something...
Forum: LIVE PLC Questions And Answers November 7th, 2018, 04:05 PM
Replies: 6
Views: 177
Posted By dmroeder
*facepalm* It's all about the details, I...

*facepalm*

It's all about the details, I didn't even notice that...
Forum: LIVE PLC Questions And Answers November 7th, 2018, 01:09 PM
Replies: 6
Views: 177
Posted By dmroeder
Do you have "CompactLogix 5370" selected for...

Do you have "CompactLogix 5370" selected for Controller Type?
edit: Also, what version of CCW?
What version does it show for the terminal in the settings page?
Forum: LIVE PLC Questions And Answers November 2nd, 2018, 08:22 PM
Replies: 7
Views: 329
Posted By dmroeder
The thing you need to watch for is when you make...

The thing you need to watch for is when you make the new runtime targeting 5.1, you cannot select the option "allow conversion". I believe it's the same when you target 6.0.
Forum: LIVE PLC Questions And Answers November 2nd, 2018, 03:35 PM
Replies: 33
Views: 2,994
Posted By dmroeder
I personally didn't get the impressions that you...

I personally didn't get the impressions that you had some stake in OIBuilder, maybe that's because I'm more familiar with your contributions over at the AdvancedHMI forum.

This is kind of the...
Forum: LIVE PLC Questions And Answers October 31st, 2018, 11:17 AM
Replies: 10
Views: 243
Posted By dmroeder
This is where I get software downloads from: ...

This is where I get software downloads from:

https://compatibility.rockwellautomation.com/Pages/MultiProductDownload.aspx?crumb=112

You're looking for "Studio 5000 Logix Designer"
Forum: LIVE PLC Questions And Answers October 29th, 2018, 01:05 PM
Replies: 8
Views: 340
Posted By dmroeder
Can you post screenshots of the following pages...

Can you post screenshots of the following pages from the EN2TR's web page?

-Diagnostic Overview
-Application Connections
-Bridged Connections

(I think those are the names of the pages,...
Forum: LIVE PLC Questions And Answers October 26th, 2018, 11:38 AM
Replies: 3
Views: 183
Posted By dmroeder
It would be no different in an APA. Again, it's...

It would be no different in an APA. Again, it's because the target hardware is not part of the development process.

Almost every file in a FactoryTalk project is a binary blob so it's hard to...
Forum: LIVE PLC Questions And Answers October 26th, 2018, 11:22 AM
Replies: 3
Views: 183
Posted By dmroeder
The MER is unaware of any model number that it...

The MER is unaware of any model number that it might be loaded into so that information is not contained in the project.

There is of course a project window size in project settings of your...
Forum: LIVE PLC Questions And Answers October 25th, 2018, 11:12 AM
Replies: 6
Views: 275
Posted By dmroeder
TheDude_Abides, probably the best username on the...

TheDude_Abides, probably the best username on the internet.

:bow:
Forum: LIVE PLC Questions And Answers October 18th, 2018, 03:19 PM
Replies: 29
Views: 8,502
Posted By dmroeder
Are you dragging/dropping it from a network...

Are you dragging/dropping it from a network drive, or is it on the local file system? Try doing it from your desktop.

edit: Nevermind, that isn't the issue. It looks like the part trying to...
Forum: LIVE PLC Questions And Answers October 18th, 2018, 11:28 AM
Replies: 6
Views: 246
Posted By dmroeder
edit: I'm in front of a keyboard now so I'll...

edit: I'm in front of a keyboard now so I'll elaborate a little. After we installed v30 (at least I think that is what did it), on about 6 or 7 machines, any v24 that we attempted to open would...
Forum: LIVE PLC Questions And Answers October 18th, 2018, 09:20 AM
Replies: 6
Views: 246
Posted By dmroeder
I had this happen with version 24 only once on...

I had this happen with version 24 only once on several machines aft after installing version 30. Had to set the user account control setting to the lowest and it quit doing it
Forum: LIVE PLC Questions And Answers October 11th, 2018, 07:26 PM
Replies: 14
Views: 334
Posted By dmroeder
"UNLOCK" is not a key switch position. They are...

"UNLOCK" is not a key switch position. They are either RUN,REM or PGM (something like that). It is important because you cannot make online changes when it is in RUN.
Forum: LIVE PLC Questions And Answers October 10th, 2018, 10:21 PM
Replies: 20
Views: 1,641
Posted By dmroeder
I think of 5069 as a platform, with controllers,...

I think of 5069 as a platform, with controllers, modules, accessories. It's just like 1769, which is a platform with controllers and modules.
Forum: LIVE PLC Questions And Answers October 9th, 2018, 09:55 AM
Replies: 2
Views: 187
Posted By dmroeder
It's a bug and Rockwell has a patch that needs to...

It's a bug and Rockwell has a patch that needs to be applied to your machine and the PanelView. KB 1072230
Forum: LIVE PLC Questions And Answers October 8th, 2018, 11:23 AM
Replies: 2
Views: 153
Posted By dmroeder
Stu, if you have a techconnect contract, check...

Stu, if you have a techconnect contract, check out KB 481121
Forum: LIVE PLC Questions And Answers October 5th, 2018, 10:38 AM
Replies: 19
Views: 720
Posted By dmroeder
Here is what it should have looked like. I have...

Here is what it should have looked like. I have 2 monitors and it worked fine, a window on each monitor. The blank looking form that people are seeing is what I see on my secondary monitor. The...
Forum: LIVE PLC Questions And Answers October 5th, 2018, 10:24 AM
Replies: 4
Views: 175
Posted By dmroeder
The address is not disappearing, the PanelView...

The address is not disappearing, the PanelView displaying 0.0.0.0 is "normal" when the Ethernet cable is not connected, unfortunately.
Forum: LIVE PLC Questions And Answers October 3rd, 2018, 03:02 PM
Replies: 13
Views: 567
Posted By dmroeder
I read prior to it coming out that this...

I read prior to it coming out that this particular type if notification cannot be disabled. It'll interesting to see if that changes in the custom rom community.

I was really hoping for a...
Forum: LIVE PLC Questions And Answers September 27th, 2018, 07:00 PM
Replies: 4
Views: 218
Posted By dmroeder
It definitely looks like VB6, so it couldn't be...

It definitely looks like VB6, so it couldn't be AHMI since it is based on .NET

edit: Garry has a good point though about the SLN file, I don't remember them being part of VB6.
Forum: LIVE PLC Questions And Answers September 19th, 2018, 10:21 PM
Replies: 151
Views: 37,472
Posted By dmroeder
Wow, I'm going to say that you probably don't...

Wow, I'm going to say that you probably don't want to be in the gigawatt club. Unless of course you own a working flux capacitor.
Forum: LIVE PLC Questions And Answers September 19th, 2018, 07:12 PM
Replies: 11
Views: 520
Posted By dmroeder
I believe you are thinking of .RSS rather than...

I believe you are thinking of .RSS rather than .ACD.

http://www.plctalk.net/qanda/showthread.php?t=54959&page=2
Forum: LIVE PLC Questions And Answers September 15th, 2018, 04:33 PM
Replies: 10
Views: 607
Posted By dmroeder
Strong possibility of a recent windows update. ...

Strong possibility of a recent windows update. There are several related to spectre and meltdown that train wrecked some Rockwell software. There are KB articles about it if you search around.
Forum: LIVE PLC Questions And Answers September 5th, 2018, 08:16 PM
Replies: 4
Views: 571
Posted By dmroeder
I actually have something that I created a while...

I actually have something that I created a while back that tells you what versions of Logix/Studio 5000 are installed. It's a function within a program that won't make sense to anyone else around...
Showing results 1 to 25 of 500

 