You are not registered yet. Please click here to register!


 
 
plc storereviewsdownloads
This board is for PLC Related Q&A ONLY. Please DON'T use it for advertising, etc.
 
Try our online PLC Simulator- FREE.  Click here now to try it.

---------->>>>>Get FREE PLC Programming Tips

New Here? Please read this important info!!!


Go Back   PLCS.net - Interactive Q & A > Search Forums

Showing results 1 to 25 of 77
Search took 0.01 seconds.
Search: Posts Made By: anthr_plcnewbie
Forum: LIVE PLC Questions And Answers July 6th, 2018, 07:59 AM
Replies: 7
Views: 1,010
Posted By anthr_plcnewbie
How can I cross reference to find all produced or...

How can I cross reference to find all produced or consumed tags in the program? Is there an easier way? Thanks.
Forum: LIVE PLC Questions And Answers June 26th, 2018, 08:29 PM
Replies: 4
Views: 656
Posted By anthr_plcnewbie
Ok, I have not been able to test this yet and I...

Ok, I have not been able to test this yet and I don't have v10 installed because I will have to download win10 x64, install it on a VM, install v10 Factorytalk on the same VM and then run it to...
Forum: LIVE PLC Questions And Answers June 21st, 2018, 07:43 PM
Replies: 1
Views: 308
Posted By anthr_plcnewbie
Measure differential 4-20mA input using an Ammeter using

We have a bunch of signals that are differential 4-20mA inputs. I was wondering how can I measure the physical current using a Fluke 787 or a Fluke 773 meter.

Thanks,
Forum: LIVE PLC Questions And Answers May 1st, 2018, 07:18 AM
Replies: 1
Views: 281
Posted By anthr_plcnewbie
JagXtreme EDS Files

I have a production line where we have several scales on Controlnet back to a L55 Controllogix. All of them were JagXtremems. One of them went bad and we replaced it with a IND570. I can find pretty...
Forum: LIVE PLC Questions And Answers February 18th, 2018, 10:43 AM
Replies: 4
Views: 656
Posted By anthr_plcnewbie
That is awesome! Thanks for confirming, I will...

That is awesome! Thanks for confirming, I will give it a shot!
Forum: LIVE PLC Questions And Answers February 17th, 2018, 05:29 PM
Replies: 4
Views: 656
Posted By anthr_plcnewbie
Factorytalk View ME - Restoring Legacy Help

I was reading on knowledgebase and came across this article. Is this article saying that it can restore v5.1 runtime file back to a development format in v10 once the patch is installed?

As the...
Forum: LIVE PLC Questions And Answers February 16th, 2018, 03:01 PM
Replies: 19
Views: 5,232
Posted By anthr_plcnewbie
I am trying to use a similar setup with a Hootoo...

I am trying to use a similar setup with a Hootoo TripMate Titan that i received. For the life of me, I am unable to get it to work.

My PLC is IP 192.168.100.2; The router is setup to give out...
Forum: LIVE PLC Questions And Answers September 29th, 2017, 10:46 AM
Replies: 2
Views: 273
Posted By anthr_plcnewbie
So we swapped out the safe speed monitor board...

So we swapped out the safe speed monitor board and it worked after just fine. It boggles my mind how the first board was bad out of the factory.
Forum: LIVE PLC Questions And Answers September 29th, 2017, 02:00 AM
Replies: 2
Views: 273
Posted By anthr_plcnewbie
DPI Error - Object State Fault

Hi,

I have a powerflex755 with safe speed monitor module card. The system while running suddenly shutdown with no apparent cause or alarms. The electricians didn't know any better and they changed...
Forum: LIVE PLC Questions And Answers May 4th, 2017, 07:15 AM
Replies: 7
Views: 491
Posted By anthr_plcnewbie
That is the correct brochure I was looking at as...

That is the correct brochure I was looking at as well.

We already have purchased the Ethernet TCP/IP modules for them. So Modbus is not feasible at this stage. Unfortunately, there is no...
Forum: LIVE PLC Questions And Answers May 4th, 2017, 06:27 AM
Replies: 7
Views: 491
Posted By anthr_plcnewbie
Moisture Meters connecting to OPC Server?

I have a moisture meter that I want connected so we can log data from it. The specs mention that it supports OPC-DDE, would that mean I can connect it to Kepserver and gather data?
Thanks.
...
Forum: LIVE PLC Questions And Answers April 19th, 2017, 02:19 PM
Replies: 12
Views: 729
Posted By anthr_plcnewbie
Thanks, I shall do that!

Thanks, I shall do that!
Forum: LIVE PLC Questions And Answers April 19th, 2017, 02:06 PM
Replies: 12
Views: 729
Posted By anthr_plcnewbie
I have a VM with all of Rockwell software...

I have a VM with all of Rockwell software installed on it. I have to change the Windows computer name of the VM, create a new user 'PROGRAMMER' with admin rights and delete completely the previous...
Forum: LIVE PLC Questions And Answers April 19th, 2017, 01:50 PM
Replies: 12
Views: 729
Posted By anthr_plcnewbie
I did change the name of the computer as well....

I did change the name of the computer as well. Would that mess up anything? Do you suggest uninstall, reinstall? I am lost. I think as you are saying, the PROGRAMMER is an administrator on the...
Forum: LIVE PLC Questions And Answers April 19th, 2017, 01:27 PM
Replies: 12
Views: 729
Posted By anthr_plcnewbie
Yes it is a Windows administrator. See Capture1. ...

Yes it is a Windows administrator. See Capture1.

It also shows in Factorytalk Administrator Console when I login to 'Network' Administration Console. See Capture2.

It does not show any Windows...
Forum: LIVE PLC Questions And Answers April 19th, 2017, 12:58 PM
Replies: 12
Views: 729
Posted By anthr_plcnewbie
I tried to create a new account called...

I tried to create a new account called 'PROGRAMMER' and gave it Administrator rights. I log into PROGRAMMER account and try to setup my Factorytalk Directory and it complains saying the same thing....
Forum: LIVE PLC Questions And Answers April 19th, 2017, 10:41 AM
Replies: 12
Views: 729
Posted By anthr_plcnewbie
How to become Factorytalk Adminsitrator

I was trying to change the name of my VM Windows user account. After that I started getting messages like "User 'X' is not a Factorytalk administrator. Log on as a Factorytalk administrator"

Any...
Forum: LIVE PLC Questions And Answers April 10th, 2017, 12:30 PM
Replies: 3
Views: 480
Posted By anthr_plcnewbie
Thanks very much for resolving my hesitation. ...

Thanks very much for resolving my hesitation.

The lowest order is actually #1 which is the module inserted in the ControlLogix itself. I understand the controller having to go in to Program mode...
Forum: LIVE PLC Questions And Answers April 10th, 2017, 12:15 PM
Replies: 3
Views: 480
Posted By anthr_plcnewbie
ControlNet addressing

I had a question regarding addressing. I already have a network where there are two nodes. The main controller is a ControlLogix L62 that has a PLC-5 as remote and another controlLogix chassis as a...
Forum: LIVE PLC Questions And Answers March 6th, 2017, 09:32 AM
Replies: 6
Views: 837
Posted By anthr_plcnewbie
http://literature.rockwellautomation.com/idc/group...

http://literature.rockwellautomation.com/idc/groups/literature/documents/qr/9324-qr001_-en-p.pdf

'FBD Editor' available separately for Standard edition.
Forum: LIVE PLC Questions And Answers February 6th, 2017, 11:45 AM
Replies: 6
Views: 1,148
Posted By anthr_plcnewbie
Thanks guys. So this will probably sound stupid...

Thanks guys. So this will probably sound stupid but there are jumpers on the card assembly that were set for differential. I am going to change them out to single ended and start back up, but I think...
Forum: LIVE PLC Questions And Answers February 6th, 2017, 07:14 AM
Replies: 6
Views: 1,148
Posted By anthr_plcnewbie
What I mean is, if I see 12mA steady signal on...

What I mean is, if I see 12mA steady signal on the meter I don't register that on the DCS. It comes up as 'Not a number' meaning it doesn't see it. We changed out the card with a brand new one. It...
Forum: LIVE PLC Questions And Answers February 4th, 2017, 10:07 AM
Replies: 6
Views: 1,148
Posted By anthr_plcnewbie
Analog input channel acting strange

My analog input 4-20mA channel are acting different. It sometimes reads a good mA value and sometimes doesn't. It happens only on 3 channels of the 6 that are being used. The rest three work just...
Forum: LIVE PLC Questions And Answers December 20th, 2016, 10:21 AM
Replies: 2
Views: 581
Posted By anthr_plcnewbie
Just looked like it dropped off. The trend was...

Just looked like it dropped off. The trend was running in RSLogix500. PLC is SLC5/04 communicating to Powerflex drive. All three variables are being polled by the in one message instruction. If loss...
Forum: LIVE PLC Questions And Answers December 20th, 2016, 09:54 AM
Replies: 2
Views: 581
Posted By anthr_plcnewbie
Powerflex 700 PI Loop Clarification

Hi,
I need some help understanding the PID loop functionality in Powerflex 700 VC. I did some trend capture on encoder speed feedback (green), PI error (red), PI speed reference output (blue). Don't...
Showing results 1 to 25 of 77

 
Forum Jump

All times are GMT -5. The time now is 12:17 PM.


.