Search: Posts Made By: cardosocea
Forum: LIVE PLC Questions And Answers Today, 11:20 AM
Replies: 3
Views: 33
Posted By cardosocea
SUS is Siemens way of collecting rent. If you are...

SUS is Siemens way of collecting rent. If you are constantly developping, I find that it is worth it (300 per year or so). If you have a certain plant to maintain, then a single version will be ok.
Forum: LIVE PLC Questions And Answers Today, 05:20 AM
Replies: 7
Views: 264
Posted By cardosocea
What does TRCV_C return as teh RCVD_LEN...

What does TRCV_C return as teh RCVD_LEN parameter? Is TSEND only running once?
Forum: LIVE PLC Questions And Answers Today, 02:52 AM
Replies: 3
Views: 127
Posted By cardosocea
In STL would be something like this: A...

In STL would be something like this:

A trigger
FP helpvariable
MOV_BLK(MydataType[0], MydataType[1], 10)
L newRecord
T MyDataType[0]

FP is the rising edge one shot. FN is the lowering edge...
Forum: LIVE PLC Questions And Answers Today, 02:48 AM
Replies: 4
Views: 142
Posted By cardosocea
I would steer away from those classes for a...

I would steer away from those classes for a couple of reasons:

- They are condensed information and it takes a certain level of knowledge to get benefit from them. The entry level ones are...
Forum: LIVE PLC Questions And Answers Yesterday, 09:33 AM
Replies: 7
Views: 876
Posted By cardosocea
Project language. PCS7 requires US English to be...

Project language. PCS7 requires US English to be defined and can only accept certain languages. This is somewhere in the settings for the project, although it's been a while since I used it.
Forum: LIVE PLC Questions And Answers Yesterday, 04:28 AM
Replies: 7
Views: 264
Posted By cardosocea
I only just noticed that the ID number being 1 is...

I only just noticed that the ID number being 1 is strange as I was configuring connections the other day and they would start at 100.
Forum: LIVE PLC Questions And Answers Yesterday, 04:27 AM
Replies: 7
Views: 876
Posted By cardosocea
PCS7 is notable to throw up errors when the...

PCS7 is notable to throw up errors when the language isn't set up correctly. Perhaps that has something to do with it?
Forum: LIVE PLC Questions And Answers Yesterday, 02:54 AM
Replies: 2
Views: 339
Posted By cardosocea
Assuming you have access to hardware... wouldn't...

Assuming you have access to hardware... wouldn't a raspberry pi running Codesys be a good starting point?

I think if you're used to TIA Portal, and from my time playing with Codesys, I think a...
Forum: LIVE PLC Questions And Answers September 15th, 2018, 03:40 AM
Replies: 7
Views: 264
Posted By cardosocea
I've been playing with UDP (not the same, I know)...

I've been playing with UDP (not the same, I know) and noticed that there is something funky with the way it seems to work.



Did you pass an IP address structure into the TCON block and if so...
Forum: LIVE PLC Questions And Answers September 10th, 2018, 01:23 PM
Replies: 4
Views: 204
Posted By cardosocea
There's also the added capacitance that can cause...

There's also the added capacitance that can cause havoc on encoder signals, whilst a repeater will (generally) reconstruct the signal to make it square again before outputing.
Forum: LIVE PLC Questions And Answers September 7th, 2018, 11:13 AM
Replies: 8
Views: 322
Posted By cardosocea
BLK_MOV could do, but your IO would have to...

BLK_MOV could do, but your IO would have to precisely match your UDT and DB.
Forum: LIVE PLC Questions And Answers September 7th, 2018, 05:55 AM
Replies: 3
Views: 99
Posted By cardosocea
It depends how you break it down really. ...

It depends how you break it down really.

I'm used to having PLC's in the same network and one port of the SCADA Servers (servers only) in that network to "speak" with the PLC's.

The Servers...
Forum: LIVE PLC Questions And Answers September 7th, 2018, 05:49 AM
Replies: 8
Views: 322
Posted By cardosocea
L DB120.DBWxxx T QWxxx

L DB120.DBWxxx
T QWxxx
Forum: LIVE PLC Questions And Answers September 7th, 2018, 04:53 AM
Replies: 8
Views: 322
Posted By cardosocea
What type of block are you doing this in? ...

What type of block are you doing this in?
Perhaps the block is one that doesn't have optimized access turned on and it won't let you do this?
Forum: LIVE PLC Questions And Answers September 7th, 2018, 04:50 AM
Replies: 6
Views: 351
Posted By cardosocea
You gave us zero useful information to help...

You gave us zero useful information to help you... Can you try again?
Forum: LIVE PLC Questions And Answers September 5th, 2018, 11:00 AM
Replies: 11
Views: 789
Posted By cardosocea
You are being too conservative... I think it's...

You are being too conservative... I think it's probably more than that. I mean, even fire detection systems use VxWorks.

I would also risk that a vast majority of shipping uses it too.
Forum: LIVE PLC Questions And Answers September 3rd, 2018, 02:14 AM
Replies: 11
Views: 789
Posted By cardosocea
Thanks. I quite like the idea of Codesys, but...

Thanks.
I quite like the idea of Codesys, but because they aren't usually seen much out in the wild, it's hard to have a grasp about any issues it may have.

I'll check that one out.
Forum: LIVE PLC Questions And Answers September 2nd, 2018, 10:05 AM
Replies: 11
Views: 789
Posted By cardosocea
What's your favourite brand @paraffin power?

What's your favourite brand @paraffin power?
Forum: LIVE PLC Questions And Answers August 31st, 2018, 03:39 AM
Replies: 9
Views: 228
Posted By cardosocea
On number 1, I'm not entirely sure. In the past...

On number 1, I'm not entirely sure. In the past that was possible, but you would have to make the backup from the Windows embedded control panel (or something similar). If the LCD isn't available, I...
Forum: LIVE PLC Questions And Answers August 30th, 2018, 09:54 AM
Replies: 25
Views: 869
Posted By cardosocea
Although I share your sentiment, the Google apps...

Although I share your sentiment, the Google apps block may actually be IT following corporate directives. At the end of the day, it's a free service that doesn't quite guarantee privacy of the...
Forum: LIVE PLC Questions And Answers August 30th, 2018, 09:51 AM
Replies: 3
Views: 189
Posted By cardosocea
Used Balluff in the past and was quite pleased...

Used Balluff in the past and was quite pleased with them.
Forum: LIVE PLC Questions And Answers August 30th, 2018, 05:33 AM
Replies: 25
Views: 869
Posted By cardosocea
My money is that he has local administrator...

My money is that he has local administrator rights on his laptop... which should be a given for a developer, but I don't know IT.
Forum: LIVE PLC Questions And Answers August 30th, 2018, 03:05 AM
Replies: 25
Views: 869
Posted By cardosocea
In one of my last jobs, I bought myself a new...

In one of my last jobs, I bought myself a new larger hard drive (luckily the laptop came with 320Gb).
Imaged the hard drive, placed the image in the new hard drive, then installed windows on the...
Forum: LIVE PLC Questions And Answers August 29th, 2018, 09:49 AM
Replies: 13
Views: 530
Posted By cardosocea
You probably need to work on a couple more...

You probably need to work on a couple more scenarios with regards to communication faults, but you could have one of the PLC's calculating the start conditions and send over the command to each...
Forum: LIVE PLC Questions And Answers August 29th, 2018, 02:31 AM
Replies: 29
Views: 941
Posted By cardosocea
Have you considered creating a proof of concept...

Have you considered creating a proof of concept system with Siemens? I don't mean actually buying hardware, but if you have the software and PLCSim, you can create an awful lot and run it off of...