Forum: LIVE PLC Questions And Answers
January 11th, 2021, 01:05 AM
|
Replies: 71
Views: 5,268
|
Forum: LIVE PLC Questions And Answers
January 10th, 2021, 04:04 PM
|
Replies: 71
Views: 5,268
|
Forum: LIVE PLC Questions And Answers
January 10th, 2021, 03:20 PM
|
Replies: 7
Views: 526
|
Forum: LIVE PLC Questions And Answers
January 9th, 2021, 04:32 PM
|
Replies: 8
Views: 453
thanks all.
I've always used relays for this...
thanks all.
I've always used relays for this reason and others.
Only reason I asked is, this time space is an issue.
Totally remember now that the inrush current is the dealio w/ the s.v.
Triac's...
|
Forum: LIVE PLC Questions And Answers
January 9th, 2021, 02:29 PM
|
Replies: 8
Views: 453
amp rating vs. inductive amp rating
What are the odds that a 2.0 amp relay output card will be able to handle the inductive load rating of aprox. 0.625A. (24VAC s.v. coil 15 watts)?
Is there a formula for converting amp ratings to...
|
Forum: LIVE PLC Questions And Answers
December 7th, 2020, 10:39 AM
|
Replies: 0
Views: 242
drive troubleshooting
Is it possible to see in an ATV212 if it is getting the frequency command via modbus?
For example: In the ATV312 you can go to FRH under the monitor menu and see it.
We are writing the rpm ref to...
|
Forum: LIVE PLC Questions And Answers
November 23rd, 2020, 01:11 PM
|
Replies: 69
Views: 5,054
|
Forum: LIVE PLC Questions And Answers
November 23rd, 2020, 01:09 PM
|
Replies: 69
Views: 5,054
|
Forum: LIVE PLC Questions And Answers
November 23rd, 2020, 12:39 PM
|
Replies: 69
Views: 5,054
|
Forum: LIVE PLC Questions And Answers
November 23rd, 2020, 12:30 PM
|
Replies: 69
Views: 5,054
|
Forum: LIVE PLC Questions And Answers
November 23rd, 2020, 12:28 PM
|
Replies: 69
Views: 5,054
|
Forum: LIVE PLC Questions And Answers
November 23rd, 2020, 11:51 AM
|
Replies: 69
Views: 5,054
|
Forum: LIVE PLC Questions And Answers
November 23rd, 2020, 10:45 AM
|
Replies: 69
Views: 5,054
|
Forum: LIVE PLC Questions And Answers
November 21st, 2020, 10:40 AM
|
Replies: 69
Views: 5,054
|
Forum: LIVE PLC Questions And Answers
November 21st, 2020, 10:37 AM
|
Replies: 69
Views: 5,054
|
Forum: LIVE PLC Questions And Answers
November 20th, 2020, 10:04 AM
|
Replies: 0
Views: 453
loving Wago right now
No need to open ports to update the program.
You have to get a little tricky and program some logic to take the plc out of run though.
But then, you can open a chrome browser and update the...
|
Forum: LIVE PLC Questions And Answers
November 19th, 2020, 10:39 PM
|
Replies: 69
Views: 5,054
|
Forum: LIVE PLC Questions And Answers
November 19th, 2020, 04:24 PM
|
Replies: 69
Views: 5,054
Here are some more details.
I've used RsView,...
Here are some more details.
I've used RsView, Cimplicity, Wonderware, Indusoft et al.
They are all buggy as get out.
I program for an OEM.
Basically, I'm like why can't I write my own thing and...
|
Forum: LIVE PLC Questions And Answers
November 18th, 2020, 02:55 PM
|
Replies: 69
Views: 5,054
|
Forum: LIVE PLC Questions And Answers
November 18th, 2020, 02:53 PM
|
Replies: 69
Views: 5,054
|
Forum: LIVE PLC Questions And Answers
November 17th, 2020, 10:10 PM
|
Replies: 69
Views: 5,054
writing an hmi from scratch using VB
Anyone have any experience doing this?
Is this too much of an undertaking to consider?
What are the biggest hurdles?
My guesses of the biggest hurdles:
SSL email, text message api
alarm history...
|
Forum: LIVE PLC Questions And Answers
August 26th, 2020, 12:43 PM
|
Replies: 4
Views: 785
|
Forum: LIVE PLC Questions And Answers
August 26th, 2020, 12:39 PM
|
Replies: 45
Views: 4,885
|
Forum: LIVE PLC Questions And Answers
August 26th, 2020, 12:28 PM
|
Replies: 45
Views: 4,885
True story: The city of Bakersfield, California...
True story: The city of Bakersfield, California fought w/ a company trying to get the plc code for their mini Vegas style fountain that spelled out stuff in water and failed. (as many have mentioned,...
|
Forum: LIVE PLC Questions And Answers
August 26th, 2020, 12:23 PM
|
Replies: 8
Views: 838
|