Search: Posts Made By: Bardes
Forum: LIVE PLC Questions And Answers May 8th, 2018, 05:22 PM
Replies: 4
Views: 714
Posted By Bardes
The xxxx.upl is a compiled file that you can...

The xxxx.upl is a compiled file that you can download directly. You may fx use a command from the debugger: F(ile) and then L(oad) to download the file.

The file contains no symbol names or...
Forum: LIVE PLC Questions And Answers May 8th, 2018, 02:54 PM
Replies: 4
Views: 714
Posted By Bardes
Hi georgeawny You will need a cable Pcd8.K111....

Hi georgeawny
You will need a cable Pcd8.K111. Google will give you the configuration.

You need PG5.1.4.300 +patch 15 + possibly a driver update.

You will find it here:...
Forum: LIVE PLC Questions And Answers February 21st, 2018, 01:54 PM
Replies: 2
Views: 337
Posted By Bardes
saia plc pcd2 m5540 xob 13 error

Hi
As mentioned XOB13 can be triggered from several errors .
The history log could indicate at what program step the error appears.
If there is a XOB13 program, it may contain debug information...
Forum: LIVE PLC Questions And Answers September 17th, 2016, 04:52 AM
Replies: 4
Views: 1,072
Posted By Bardes
Henny We have a customer using a an older 545...

Henny
We have a customer using a an older 545 cpu with a 505-6851. I need to know what versions of 6851 I can use if the 6851 fails.
Referring to the manual 505-8201-3, posted by Dravik, this...
Forum: LIVE PLC Questions And Answers September 16th, 2016, 08:55 AM
Replies: 4
Views: 1,072
Posted By Bardes
Ti505 RBC

TI505/SimaticTI505 plc serie (CPU 545/555/575) used a Remote base Controller 505-6851. There were also versions 505-6851A (and 505-6851B, I think). I think they are newer versions. What is the...
Forum: LIVE PLC Questions And Answers March 17th, 2013, 06:33 PM
Replies: 4
Views: 808
Posted By Bardes
Online connection is covered in the Tisoft...

Online connection is covered in the Tisoft manual. I can email the 6.3 version.
Bardes
Forum: LIVE PLC Questions And Answers November 11th, 2010, 12:32 PM
Replies: 4
Views: 1,552
Posted By Bardes
At the Saia support page:...

At the Saia support page: http://www.sbc-support.ch/
Look at product code index\PG5\PG5 2.0 (current version)\PG5 2.0 Suite
There is a programming manual for download. Besides the help is quite...
Forum: LIVE PLC Questions And Answers November 9th, 2010, 06:50 PM
Replies: 4
Views: 1,552
Posted By Bardes
Saia PG5.2

The demo version is a full version for 90 days. (standard libraries only)
What choices were made when you disassembled the file?
(listing, source files, single source files, block separated,block...
Forum: LIVE PLC Questions And Answers May 27th, 2010, 03:10 PM
Replies: 19
Views: 9,117
Posted By Bardes
Think this is the cable from pc to VT510 PC...

Think this is the cable from pc to VT510

PC side VT side
9 pin female 25 pin male

3 -------------------------------------- 2
2...
Forum: LIVE PLC Questions And Answers April 21st, 2010, 04:44 PM
Replies: 5
Views: 983
Posted By Bardes
1. You could use the WAND instruction with a...

1. You could use the WAND instruction with a constant 1111111100000000. It will give a 1 for output if there are 1 among the first 8 bit.
2. You may also use MWIR to move bits in words to C...
Forum: LIVE PLC Questions And Answers March 15th, 2010, 07:06 PM
Replies: 4
Views: 1,626
Posted By Bardes
Is there a error code in the cpu? - Is the...

Is there a error code in the cpu?
- Is the power to exp.power ok?
- problem with cable or backplane in rack1?
Forum: LIVE PLC Questions And Answers March 12th, 2010, 12:37 PM
Replies: 13
Views: 12,022
Posted By Bardes
Sorry. I was trying to make a link to a matricon...

Sorry. I was trying to make a link to a matricon page, not a mailbox.
My linking should be: ...
Forum: LIVE PLC Questions And Answers March 11th, 2010, 12:22 PM
Replies: 13
Views: 12,022
Posted By Bardes
MatrikonOPC History Link...

MatrikonOPC History Link (https://webmail.malthe-winje.no/exchweb/bin/redir.asp?URL=http://www.e-matrikon.com:80/CT00275401NDA3NjIA.HTML) is a flexible tool that provides seamless data transfer...
Forum: LIVE PLC Questions And Answers March 10th, 2010, 02:18 PM
Replies: 1
Views: 1,681
Posted By Bardes
Here are some links you could check: 1....

Here are some links you could check:
1. http://www.classicautomation.com/Catalog/ProductDetail.aspx?partnum=505-6660&gclid=CIqUk4H_rqACFUGF3godTj6Seg
2....
Forum: LIVE PLC Questions And Answers February 28th, 2010, 06:11 AM
Replies: 2
Views: 651
Posted By Bardes
Hi Try this config file. It is for a CTI 2500...

Hi
Try this config file. It is for a CTI 2500 plc (TI545 compatible). The OPC is sold by CTI but a think it is a branded kepware product.
Bardes
Forum: LIVE PLC Questions And Answers January 26th, 2010, 02:08 PM
Replies: 1
Views: 1,805
Posted By Bardes
The Saia PG5 software consists of several...

The Saia PG5 software consists of several libraries. The programmer may also have used 3.party libraries or his own user produced libraries. PG5 will not know the source. This makes it a impossible...
Forum: LIVE PLC Questions And Answers January 11th, 2010, 05:58 PM
Replies: 19
Views: 9,117
Posted By Bardes
Hi warbuff08 1. Make a directory c:\dosbox ...

Hi warbuff08
1. Make a directory c:\dosbox
2. append to your autoexec.bat:
" mount c: c:\dosbox
cd c:\"
This will make the c drive for your program to install correct

Regards Bardes
Forum: LIVE PLC Questions And Answers September 15th, 2009, 11:24 AM
Replies: 5
Views: 2,355
Posted By Bardes
The cpu's < 545 dont have a clock Bardes

The cpu's < 545 dont have a clock
Bardes
Forum: LIVE PLC Questions And Answers July 2nd, 2009, 01:17 PM
Replies: 2
Views: 940
Posted By Bardes
If you use the TI305 or 405 you can use the...

If you use the TI305 or 405 you can use the software from directsoft.
Bardes
Forum: LIVE PLC Questions And Answers May 20th, 2009, 03:13 PM
Replies: 10
Views: 2,774
Posted By Bardes
If you let the CTI 2500 CPU be the slave (server)...

If you let the CTI 2500 CPU be the slave (server) and the S7-300 the master (client) I guess it would work.
In case your application need the CTI 2500 CPU to control sending you can signal start...
Forum: LIVE PLC Questions And Answers May 16th, 2009, 06:11 AM
Replies: 10
Views: 7,233
Posted By Bardes
What operating system do you have on your STEP5...

What operating system do you have on your STEP5 partitition?
If it is Dos/WIN95/98 you should be able to copy your tisoft program to the parttion and run it. There may be settings to change in...
Forum: LIVE PLC Questions And Answers May 14th, 2009, 05:00 PM
Replies: 19
Views: 9,117
Posted By Bardes
You can use dosbox dos emulator to run your VT...

You can use dosbox dos emulator to run your VT Prog in newer Windows versions .

Bardes
Forum: LIVE PLC Questions And Answers March 12th, 2009, 06:25 PM
Replies: 2
Views: 1,208
Posted By Bardes
OPC server CTI 2500

Contact CTI. They have a OPC server (branded)that you can use via CPU ethernett port.
Forum: LIVE PLC Questions And Answers February 24th, 2009, 12:46 PM
Replies: 4
Views: 967
Posted By Bardes
file:///C:/DOCUME%7E1/ESPEDA%7E1.OBE/LOCALS%7E1/Te...

file:///C:/DOCUME%7E1/ESPEDA%7E1.OBE/LOCALS%7E1/Temp/moz-screenshot-1.jpgSoftware for 525/545/560/560/5 series Siemens and TI controllers as well as CTI controllers
...
Forum: LIVE PLC Questions And Answers December 13th, 2008, 07:14 AM
Replies: 2
Views: 1,525
Posted By Bardes
Hi Thanks for your reply! I expected it would...

Hi
Thanks for your reply! I expected it would perform ok. I'm aware of the need for font substitution. Just needed some user experience, as other operating systems are ver. 7.x.

Regards
Bardes
Showing results 1 to 25 of 37

 