Forum: LIVE PLC Questions And Answers November 9th, 2018, 10:49 PM
Replies: 18
Views: 908
Posted By Bullzi
Thanks for all the advice everyone, I did...

Thanks for all the advice everyone,
I did confirm that the tank will be insulated. I hope it is done before I start up the system otherwise it will make the tuning very difficult.

I do have a...
Forum: LIVE PLC Questions And Answers November 8th, 2018, 09:17 PM
Replies: 18
Views: 908
Posted By Bullzi
Thanks for all the replies everyone, Let me see...

Thanks for all the replies everyone,
Let me see if I can answer some questions:

Fluid: Bio-Diesel
The heaters were sized by others I was just told to make them work with my system. So I hope...
Forum: LIVE PLC Questions And Answers November 7th, 2018, 06:35 PM
Replies: 18
Views: 908
Posted By Bullzi
Opinions: Tank Heating Control

Hi Everyone,
I am about to complete a panel that controls 2) 12kW 480VAC Tank Heaters. Thanks to everyone that helped me on my previous thread about designing of the panels. I have designed the...
Forum: LIVE PLC Questions And Answers October 29th, 2018, 04:28 PM
Replies: 12
Views: 394
Posted By Bullzi
Do you ever reset the DINT to zero? Or does it...

Do you ever reset the DINT to zero? Or does it just keep counting up? If so you may have counted too high for the DINT to hold.

You can add 1 to a REAL too, that way skipping the step of having...
Forum: LIVE PLC Questions And Answers October 17th, 2018, 07:29 PM
Replies: 10
Views: 623
Posted By Bullzi
Remote access to a PLC Panel

Hi everyone,

I am not very well versed in the IT stuff. I know enough to be dangerous and to be able to tell the IT people what I need.

I am building a couple of panels that have a Red Lion...
Forum: LIVE PLC Questions And Answers October 16th, 2018, 12:05 PM
Replies: 17
Views: 798
Posted By Bullzi
I would go with a protocol converter like a Data...

I would go with a protocol converter like a Data Station Plus from Red Lion to do this.
Forum: LIVE PLC Questions And Answers October 13th, 2018, 01:21 PM
Replies: 15
Views: 558
Posted By Bullzi
Here is how I went about it. Sampling every...

Here is how I went about it. Sampling every minute may end up being to slow, especially if your flow rates change during that minute. You could end up with a lot of error. Sampling 10 times a...
Forum: LIVE PLC Questions And Answers October 11th, 2018, 07:26 PM
Replies: 15
Views: 558
Posted By Bullzi
Hi and welcome to the forum, Is your flow...

Hi and welcome to the forum,

Is your flow rate in GPM? If so I would set a 6 second timer and move the flow rate every 6 seconds into a register. Then take that rate in GPM and divide by 10 (6...
Forum: LIVE PLC Questions And Answers October 7th, 2018, 08:01 PM
Replies: 2
Views: 219
Posted By Bullzi
I have a couple guys using it on Win 10 and it is...

I have a couple guys using it on Win 10 and it is working great.
Forum: LIVE PLC Questions And Answers October 4th, 2018, 09:02 PM
Replies: 7
Views: 731
Posted By Bullzi
Yes I would like to see that. Will be starting...

Yes I would like to see that. Will be starting one with L18 and a ATV 930. That would help me get started.
Forum: LIVE PLC Questions And Answers October 1st, 2018, 01:22 PM
Replies: 9
Views: 413
Posted By Bullzi
Solar Power for remote panel

Happy Monday to everyone,

I have posted a few post lately regarding Click PLC, Soil Moisture Probe and Cell Modems. Now I am trying to power this combo using a Solar Panel and Batteries.

Seen...
Forum: LIVE PLC Questions And Answers September 28th, 2018, 09:58 PM
Replies: 18
Views: 769
Posted By Bullzi
Dan, Yes and no. I am looking for a cell modem...

Dan,
Yes and no. I am looking for a cell modem for a diffrent job that will use a ML1100 and a Red Lion HMI. The other job just has a moisture sensor (I posted about that too). I was thinking of...
Forum: LIVE PLC Questions And Answers September 28th, 2018, 08:47 PM
Replies: 27
Views: 838
Posted By Bullzi
I have been using the polynomial method to...

I have been using the polynomial method to calculate tank volumes based on a tank strapping chart. The chart gives many different levels with a volume for each level. So in this case the FGEN is...
Forum: LIVE PLC Questions And Answers September 28th, 2018, 08:36 AM
Replies: 2
Views: 212
Posted By Bullzi
Thanks Saffa, This looks like what I am looking...

Thanks Saffa,
This looks like what I am looking for!!
Forum: LIVE PLC Questions And Answers September 28th, 2018, 01:00 AM
Replies: 18
Views: 769
Posted By Bullzi
Cellular Modems

I have a project that is in a remote location. There will be a PLC and HMI in the panel and the customer wants to be able to monitor and even control the system over a Cell Modem.

I am planning...
Forum: LIVE PLC Questions And Answers September 28th, 2018, 12:53 AM
Replies: 2
Views: 212
Posted By Bullzi
Soil Moisture Sensor

I just got a interesting request. I have a customer that is wanting to detect how much moisture there is in the soil around a Pipeline. I have never used a moisture sensor before and most of what I...
Forum: LIVE PLC Questions And Answers September 28th, 2018, 12:35 AM
Replies: 23
Views: 1,089
Posted By Bullzi
Thanks Dan!! I know it gets cold up in your neck...

Thanks Dan!! I know it gets cold up in your neck of the woods :)
Forum: LIVE PLC Questions And Answers September 27th, 2018, 11:52 PM
Replies: 8
Views: 398
Posted By Bullzi
These are also called On Shots in other PLC's. ...

These are also called On Shots in other PLC's. Basically they are instructions that will remain true for one scan of the PLC when the bit that is referenced in the instruction goes from off to on...
Forum: LIVE PLC Questions And Answers September 27th, 2018, 11:20 PM
Replies: 23
Views: 1,089
Posted By Bullzi
Thanks everyone for the info, I did think about...

Thanks everyone for the info,
I did think about the Micro 820 PLC. I haven't used a Micro 800 since right after they were released and CCW was a nightmare. I have CCW just kind of gun shy to use...
Forum: LIVE PLC Questions And Answers September 27th, 2018, 11:17 PM
Replies: 27
Views: 838
Posted By Bullzi
That is what I love about this Forum!! I have...

That is what I love about this Forum!! I have been using the Excel Polynomial method for years. It has working for the most part but was always off at the extreme ends of the curve. I just re did...
Forum: LIVE PLC Questions And Answers September 27th, 2018, 02:18 PM
Replies: 27
Views: 838
Posted By Bullzi
Never seen a 4-20mA transmitter that wasn't...

Never seen a 4-20mA transmitter that wasn't linear. What kind of transmitter is it?
Forum: LIVE PLC Questions And Answers September 27th, 2018, 11:19 AM
Replies: 11
Views: 455
Posted By Bullzi
In my area the Oil & Gas fields are very active....

In my area the Oil & Gas fields are very active. New wells and equipment are going in all the time. So most of the company guys spend their day lining out contractors and following up on the work. I...
Forum: LIVE PLC Questions And Answers September 27th, 2018, 11:11 AM
Replies: 23
Views: 1,089
Posted By Bullzi
Click PLC Field Experience

Hi everyone,
I have started work on a couple of jobs that I think a Click PLC would be perfect for. The problem is I have zero experience with them in the field. I have one on my test bench and I...
Forum: LIVE PLC Questions And Answers September 26th, 2018, 05:42 PM
Replies: 11
Views: 455
Posted By Bullzi
Are you talking about direct hire for a O&G...

Are you talking about direct hire for a O&G company or being a Contractor in the O&G business? Are you talking Refinery work or field work?

Major difference on the day to day activities in the 2.
Forum: LIVE PLC Questions And Answers September 14th, 2018, 10:16 AM
Replies: 4
Views: 212
Posted By Bullzi
Here is a snip from the manual.

Here is a snip from the manual.