Posted By Dravik
It depends on what the bit array was doing in...

It depends on what the bit array was doing in your old program.

http://www.plctalk.net/qanda/archive/index.php/t-93915.html
http://www.plctalk.net/qanda/archive/index.php/t-74609.html

Those...
Forum: LIVE PLC Questions And Answers December 14th, 2017, 12:59 PM
Replies: 5
Views: 102
Posted By Dravik
If you add the traceroute option to your scans in...

If you add the traceroute option to your scans in nmap, you can use the topology display.
I forget the exact syntax but it is in the help file.
Forum: LIVE PLC Questions And Answers December 14th, 2017, 12:57 PM
Replies: 11
Views: 379
Posted By Dravik
So, check internet options - advanced - turn...

So, check internet options - advanced -
turn off Check for Publisher's Certificate Revocation
turn off Check for Server Certificate Revocation

Reboot and then see if it works better, If it does...
Forum: LIVE PLC Questions And Answers December 14th, 2017, 12:49 PM
Replies: 5
Views: 102
Posted By Dravik
Yep, -h # Might have better luck w/...

Yep, -h #

Might have better luck w/ something like nmap though.
Forum: LIVE PLC Questions And Answers December 14th, 2017, 08:51 AM
Replies: 6
Views: 251
Posted By Dravik
Depending on the complexity of the inspection,...

Depending on the complexity of the inspection, I've done this with the insight series from cognex, the iv series from keyence, or a full fledged vision system from Systech/Optel/Laetus.

Cost of...
Forum: LIVE PLC Questions And Answers December 12th, 2017, 09:05 AM
Replies: 9
Views: 222
Posted By Dravik
I opened it w/ a hex editor , doesn't look like a...

I opened it w/ a hex editor , doesn't look like a normal .rss file at all.
Forum: LIVE PLC Questions And Answers December 11th, 2017, 03:21 PM
Replies: 10
Views: 295
Posted By Dravik
Read only or do the computers talk back? IF...

Read only or do the computers talk back?
IF read only, Could use a splitter instead and not fuss w/ switching contacts..
Forum: LIVE PLC Questions And Answers December 11th, 2017, 10:12 AM
Replies: 16
Views: 836
Posted By Dravik
I know the thread you're referring too. I...

I know the thread you're referring too.

I suspect that the section of discussion on how to bypass the forum text filters probably didn't help it stick around.
Buut, i'm just spitballing here.
Forum: LIVE PLC Questions And Answers December 11th, 2017, 09:49 AM
Replies: 8
Views: 121
Posted By Dravik
You can use the bootp/dhcp utility to reset the...

You can use the bootp/dhcp utility to reset the IP as long as you know the MAC address and can hook a cable directly to the device you want to reset.

Open the utility, add a new relation, enter...
Forum: LIVE PLC Questions And Answers December 9th, 2017, 10:23 AM
Replies: 7
wow
Views: 552
Posted By Dravik
SHODAN is the primary antagonist of a really...

SHODAN is the primary antagonist of a really excellent game called System Shock, came out mid 90s.

Fantastic character, great lines.

Car washes are cool tho.
Forum: LIVE PLC Questions And Answers December 8th, 2017, 09:52 PM
Replies: 7
wow
Views: 552
Posted By Dravik
Welp, guess i'm reinstalling that game and...

Welp, guess i'm reinstalling that game and playing it tomorrow. Awesome!

"You travel within the glory of my memories, insect. I can feel your fear as you tread the endless expense of my mind. Make...
Forum: LIVE PLC Questions And Answers December 8th, 2017, 11:09 AM
Replies: 6
Views: 135
Posted By Dravik
Well, i can't quite read that image. But I would...

Well, i can't quite read that image. But I would check to see why it appears you are writing to the wall clock every scan?
I can't think of a good reason to be doing that, but I didn't write that...
Forum: LIVE PLC Questions And Answers December 8th, 2017, 10:23 AM
Replies: 6
Views: 135
Posted By Dravik
Well, if you are talking one of the Control or...

Well, if you are talking one of the Control or CompactLogic processors, I believe that error relates to the wallclock time changing backwards during trending.
Might see if you have any SSV or PTP...
Forum: LIVE PLC Questions And Answers December 5th, 2017, 04:07 PM
Replies: 5
Views: 126
Posted By Dravik
Sure, you can network your VMware VM to the same...

Sure, you can network your VMware VM to the same network as the panel and use the transfer utility.
You can create the .mer, put it on a USB key and DL to the panel that way.
You can create the...
Forum: LIVE PLC Questions And Answers December 5th, 2017, 01:07 PM
Replies: 5
Views: 126
Posted By Dravik
Yes, you can build the .mer (Application Runtime...

Yes, you can build the .mer (Application Runtime for ME projects) and transfer to your HMI panel via any number of methods.
Forum: LIVE PLC Questions And Answers December 5th, 2017, 09:49 AM
Replies: 3
Views: 79
Posted By Dravik
Yep, but you're going to need RsNetworx for...

Yep, but you're going to need RsNetworx for Devicenet. Essentially you will go online w/ the existing network and grab the scanlist into a project.

As a sidenote, If you have controlnet or...
Forum: LIVE PLC Questions And Answers December 5th, 2017, 09:21 AM
Replies: 3
Views: 79
Posted By Dravik
https://rockwellautomation.custhelp.com/app/answer...

https://rockwellautomation.custhelp.com/app/answers/detail/a_id/473531

That's the technote for replacing them.

Long story short, you will need to download the scanlist to the new one.
Forum: LIVE PLC Questions And Answers December 4th, 2017, 04:44 PM
Replies: 1
Views: 63
Posted By Dravik
view.exe is part of Fix32, I don't recall it...

view.exe is part of Fix32, I don't recall it being present w/ the newer iFix systems at all. I presume your graphics files are .odf then?
Forum: LIVE PLC Questions And Answers December 1st, 2017, 11:47 AM
Replies: 9
Views: 185
Posted By Dravik
Yeah, best of my knowledge the default feedback...

Yeah, best of my knowledge the default feedback on the 753s is Speed and you can't change it. I believe you CAN change it on the 700 series drives, but i've never tried.

Now, depending on how...
Forum: LIVE PLC Questions And Answers December 1st, 2017, 10:11 AM
Replies: 9
Views: 185
Posted By Dravik
You can't change datalinks online, those are...

You can't change datalinks online, those are changed offline and downloaded back to the processor(because you change the module config to do this).
This might be helpful...
Forum: LIVE PLC Questions And Answers November 29th, 2017, 08:10 AM
Replies: 2
Views: 88
Posted By Dravik
So that's a Serial to Ethernet device right? ...

So that's a Serial to Ethernet device right?

The basic way you'd use this to talk to a field device would be to connect directly from the Moxa to the Field Device and then map a software COM port...
Forum: LIVE PLC Questions And Answers November 22nd, 2017, 01:53 PM
Replies: 6
Views: 202
Posted By Dravik
So, I did this for a different controller( and...

So, I did this for a different controller( and parsed the output of the CLI utility using perl for an Ignition box.

Should be able to write something to do the same trick for IFix, look at the...
Forum: LIVE PLC Questions And Answers November 21st, 2017, 08:32 AM
Replies: 1
Views: 145
Posted By Dravik
If you want to program both ME and SE...

If you want to program both ME and SE applications, you'll want to get 9701-VWSTENE FactoryTalk View Studio for FactoryTalk View.

For the others, I think you'll want to talk to your local...
Forum: LIVE PLC Questions And Answers November 20th, 2017, 01:47 PM
Replies: 7
Views: 334
Posted By Dravik
The ones we used spat out a string of serial data...

The ones we used spat out a string of serial data on request, did a lot of parsing to make sense of it.
Forum: LIVE PLC Questions And Answers November 17th, 2017, 04:09 PM
Replies: 11
Views: 269
Posted By Dravik
I have an example, but my program was done in...

I have an example, but my program was done in 5000 using the ethernet comms. So a little different, but you're welcome to it if you're interested.
Showing results 1 to 25 of 500

 
Forum Jump

All times are GMT -5. The time now is 05:32 PM.


.