Search: Posts Made By: tacm
Forum: LIVE PLC Questions And Answers January 20th, 2010, 03:40 PM
Replies: 2
Views: 1,985
Posted By tacm
Micrologix 1400 firmware email question

Hi folks,

A recent change has our email port 25 blocked. This has been no problem with email from PC's, as we can specify another port in Outlook, etc. MicroLogix 1400 firmware hardcodes email...
Forum: LIVE PLC Questions And Answers June 18th, 2009, 02:27 PM
Replies: 3
Views: 4,128
Posted By tacm
Really a little of both, I was able to...

Really a little of both, I was able to enableChannel 1 smtp and enter my "to" email adresses
I am assuming that the email server is the ip address that my IT department assigns to the plc. What is...
Forum: LIVE PLC Questions And Answers June 18th, 2009, 12:59 PM
Replies: 3
Views: 4,128
Posted By tacm
Micrologix 1400 networking and e-mail

I am in need of having a machine (sewage lift station) send a message when it is in alarm status. After talking to my AB rep I have desided on the ML1400. I am rather new to this processor, from...
Forum: LIVE PLC Questions And Answers January 22nd, 2009, 09:49 AM
Replies: 18
Views: 7,040
Posted By tacm
X2 thats what I do

X2 thats what I do
Forum: LIVE PLC Questions And Answers January 21st, 2009, 12:13 PM
Replies: 10
Views: 2,596
Posted By tacm
I feel like my avatar today.........my house was...

I feel like my avatar today.........my house was broken into last night, and I only got a 1/2 hour of sleep
Forum: LIVE PLC Questions And Answers January 21st, 2009, 12:11 PM
Replies: 10
Views: 2,596
Posted By tacm
rung 1 XIC I:0.0/1 XIO I:0.0/2 TON T4:1 1.0 1 0 ...

rung 1 XIC I:0.0/1 XIO I:0.0/2 TON T4:1 1.0 1 0

rung 2 XIC T4:1/TT OTE O:0.0/0

If XIC I:0.0/1 stays true and XIO I:0.0/2 toggles the timer will reset. yes?
Forum: LIVE PLC Questions And Answers January 21st, 2009, 11:43 AM
Replies: 10
Views: 2,596
Posted By tacm
Paul, you are not using a (res) you are relying...

Paul, you are not using a (res) you are relying on the true false rung transision of B10/11 to reset the TON?
Forum: LIVE PLC Questions And Answers January 21st, 2009, 10:53 AM
Replies: 10
Views: 2,596
Posted By tacm
Thank you but I cannot right now, hovever this...

Thank you but I cannot right now, hovever this has been bothering me since yesterday afternoon.
Forum: LIVE PLC Questions And Answers January 21st, 2009, 10:36 AM
Replies: 10
Views: 2,596
Posted By tacm
Momentary output energize rs 500

I have a problem with a line of code I am trying. I have an output i need to energize for two seconds and then drop out, although the input that is associated with the output will remain true. I...
Forum: LIVE PLC Questions And Answers January 19th, 2009, 11:23 AM
Replies: 3
Views: 827
Posted By tacm
RS 500 timer question

Will a T4.0/EN command energize a timer if the timer rung is not true. I want to do this

[]----------------------------(T4.0/EN)

[dummy bit]------------------(T4.0) timing
Forum: LIVE PLC Questions And Answers January 16th, 2009, 12:28 PM
Replies: 2
Views: 1,153
Posted By tacm
HELP!!!!! Im down rslogix 500 install issue

Well the lap top just hit the floor with a crash. I need to reinstall on another machine. I canot reach anyone at my distributor and I cant remember where to paste the .lic file for the usb dongle ...
Forum: LIVE PLC Questions And Answers January 14th, 2009, 10:33 AM
Replies: 3
Views: 2,875
Posted By tacm
There is a free download version for the...

There is a free download version for the micrologix 1000 if you have a 1100, 1200, 1400, or 1500 you will need rslogix 500 starter at a minimum that runs around $600.00 The starter version does not...
Forum: LIVE PLC Questions And Answers January 14th, 2009, 09:39 AM
Replies: 0
Views: 2,227
Posted By tacm
Fanuc FAPT Ladder gurus wanted ;)

Hello all,

I am working on a Mori Seiki MT2000. I am adding a new process to this machine. I will be using an AB plc as a stand alone controller. However, I need to add one rung of code to the...
Forum: LIVE PLC Questions And Answers January 9th, 2009, 07:47 AM
Replies: 310
Views: 81,699
Posted By tacm
You could not be more wrong with this statement. ...

You could not be more wrong with this statement. LOTO and safety is EVERYONES responsibility. Anyone who works around machines can be in danger of losing their lives. Work is a job, there is no...
Forum: LIVE PLC Questions And Answers January 8th, 2009, 07:43 AM
Replies: 310
Views: 81,699
Posted By tacm
x2

x2
Forum: LIVE PLC Questions And Answers January 7th, 2009, 09:40 AM
Replies: 7
Views: 2,733
Posted By tacm
It is created when you close the project file.

It is created when you close the project file.
Forum: LIVE PLC Questions And Answers December 31st, 2008, 07:47 AM
Replies: 6
Views: 1,824
Posted By tacm
If he had a copy of the application, he would not...

If he had a copy of the application, he would not need to back it up :huh:
Forum: LIVE PLC Questions And Answers December 30th, 2008, 10:01 AM
Replies: 70
Views: 17,248
Posted By tacm
X2 Well said

X2 Well said
Forum: LIVE PLC Questions And Answers December 24th, 2008, 02:13 PM
Replies: 4
Views: 1,288
Posted By tacm
SOT Relay wireing question

OK, I have seen this many times in the past, but I am not sure of the exact reason for doing it. When wiring a relay socket base, why is there a diode between 13 and 14 (coil wires) I have seen...
Forum: LIVE PLC Questions And Answers December 22nd, 2008, 11:10 AM
Replies: 2
Views: 746
Posted By tacm
Thanx.......dont know why I was unable to find it...

Thanx.......dont know why I was unable to find it :huh:
Forum: LIVE PLC Questions And Answers December 22nd, 2008, 10:56 AM
Replies: 2
Views: 746
Posted By tacm
Micrilogix 1000 dimensions

Hello, I searched the AB web site, but I could not locate a drawing of this controler. Does anyone know the dimensions of a micrologix 1000 cat number 1761-L10BWB It is the standard 6 in 4 out. I...
Forum: LIVE PLC Questions And Answers December 18th, 2008, 09:28 AM
Replies: 62
Views: 9,201
Posted By tacm
***** it........whos economy is in good shape? ...

***** it........whos economy is in good shape? Ill move. Canada? Austrailia? Somewhere where I can get by with only speaking english.....lol
Forum: LIVE PLC Questions And Answers December 17th, 2008, 07:54 AM
Replies: 13
Views: 2,019
Posted By tacm
Sato print engines are very reliable, also take a...

Sato print engines are very reliable, also take a look at what markem has to offer.
Forum: LIVE PLC Questions And Answers December 17th, 2008, 07:49 AM
Replies: 54
Views: 10,433
Posted By tacm
I agree, in addition how about upgradeable...

I agree, in addition how about upgradeable memory. I also belive all PLCs should support on-line editing.
Forum: LIVE PLC Questions And Answers December 16th, 2008, 10:45 AM
Replies: 5
Views: 1,156
Posted By tacm
Yep thats the way big bussiness works :(

Yep thats the way big bussiness works :(
Showing results 1 to 25 of 105

 