You are not registered yet. Please click here to register!


 
 
plc storereviewsdownloads
This board is for PLC Related Q&A ONLY. Please DON'T use it for advertising, etc.
 
Try our online PLC Simulator- FREE.  Click here now to try it.

---------->>>>>Get FREE PLC Programming Tips

New Here? Please read this important info!!!


Go Back   PLCS.net - Interactive Q & A > Search Forums

Showing results 1 to 25 of 259
Search took 0.06 seconds.
Search: Posts Made By: goghie
Forum: LIVE PLC Questions And Answers November 15th, 2018, 02:50 PM
Replies: 6
Views: 99
Posted By goghie
So you can program FX3U, and configure for...

So you can program FX3U, and configure for example FX3U-ENET for Modbus TCP/IP on port 502, or for MC protocol on some other port, and than you can program second HMI to access to PLC.
Forum: LIVE PLC Questions And Answers November 15th, 2018, 01:15 PM
Replies: 8
Views: 175
Posted By goghie
FX3U-ENET for FX3U, and FX2NC-ENET-ADP for FX2.

FX3U-ENET for FX3U, and FX2NC-ENET-ADP for FX2.
Forum: LIVE PLC Questions And Answers November 15th, 2018, 01:04 PM
Replies: 6
Views: 99
Posted By goghie
So I would presume that it is connected through...

So I would presume that it is connected through side connector (RS422/485/232) on HMI to Mini DIN connector on FX. If the PLC is not the one with built in Ethernet, that means that you need to have...
Forum: LIVE PLC Questions And Answers November 14th, 2018, 04:34 PM
Replies: 6
Views: 99
Posted By goghie
When you connect to FX3 through E W O N router...

When you connect to FX3 through E W O N router your computer sees that PLC as if it is directly connected with LAN cable. You can use SoftGOT or any other solution as long is it programmed/configured...
Forum: LIVE PLC Questions And Answers November 14th, 2018, 03:54 PM
Replies: 19
Views: 585
Posted By goghie
Internal model control (IMC). I've found it...

Internal model control (IMC). I've found it useful when there is a big lag in response.
Forum: LIVE PLC Questions And Answers November 12th, 2018, 06:37 PM
Replies: 2
Views: 159
Posted By goghie
45kW DC motor change with AC - advice?

Hi,
I have to retrofit one plant, intended for cream production. There is DC motor 45kW (up to 3000RPM, 440V)which is driving emulsifier and I would like to change it with 55kW VFD driven 400V AC...
Forum: LIVE PLC Questions And Answers November 8th, 2018, 03:12 AM
Replies: 3
Views: 217
Posted By goghie
Register on Mitsubishi Factory Automation and...

Register on Mitsubishi Factory Automation and then you can download a lot of manuals and e-trainings.
Forum: LIVE PLC Questions And Answers November 6th, 2018, 03:49 PM
Replies: 9
Views: 310
Posted By goghie
The other one is 330 Ohm and it is used for...

The other one is 330 Ohm and it is used for two-pair wiring, and 110 Ohm is used for one-pair wiring. To conclude what is in one end needs to be on other end. If SDA and RDA are in short circuit, and...
Forum: LIVE PLC Questions And Answers November 6th, 2018, 02:07 PM
Replies: 9
Views: 310
Posted By goghie
Make sure that you are using the correct terminal...

Make sure that you are using the correct terminal resistor 110 Ohm, 1/2W (3 brown stripes and one silver or gold), connected between RDA and RDB. Cable should be shielded twisted pair. Shield should...
Forum: LIVE PLC Questions And Answers November 6th, 2018, 12:16 PM
Replies: 9
Views: 310
Posted By goghie
What is the type of robot controller?

What is the type of robot controller?
Forum: LIVE PLC Questions And Answers November 6th, 2018, 10:19 AM
Replies: 5
Views: 147
Posted By goghie
Yes and no. %MW is not address for...

Yes and no.
%MW is not address for real/floating it is for integer.
Simple solution would be to convert it in integer and result (integer) would be without float part, but if it is %MW than i...
Forum: LIVE PLC Questions And Answers November 6th, 2018, 10:14 AM
Replies: 9
Views: 310
Posted By goghie
Because of characteristic impedance. You want to...

Because of characteristic impedance. You want to eliminate reflections - but you need to mach resistance in order to absorb it.
You posted previously one picture of panel where the cables look like...
Forum: LIVE PLC Questions And Answers November 2nd, 2018, 03:21 PM
Replies: 12
Views: 790
Posted By goghie
https://www.youtube.com/watch?v=PUUNKi_TS54

https://www.youtube.com/watch?v=PUUNKi_TS54
Forum: LIVE PLC Questions And Answers October 16th, 2018, 02:24 PM
Replies: 17
Views: 345
Posted By goghie
Sorry, I must have misunderstood you. It seemed...

Sorry, I must have misunderstood you. It seemed to me that you complain because you need to pay somebody to do it. Sorry once again, my bad English.
Forum: LIVE PLC Questions And Answers October 16th, 2018, 01:25 PM
Replies: 17
Views: 345
Posted By goghie
Yes, but that is totaly legal. We are investing,...

Yes, but that is totaly legal. We are investing, constantly learning and taking ressponsability for finishing the job right and we pay our living from that. On other side you can go after work and...
Forum: LIVE PLC Questions And Answers October 5th, 2018, 06:30 AM
Replies: 15
Views: 1,666
Posted By goghie
I think GX IEC Developer is Codesys V2. Extension...

I think GX IEC Developer is Codesys V2. Extension of file is .pro and it has that look and syntax..
Forum: LIVE PLC Questions And Answers October 2nd, 2018, 10:59 AM
Replies: 18
Views: 480
Posted By goghie
Is it 64bit Windows, and if yes - please give me...

Is it 64bit Windows, and if yes - please give me some directions how to do it?
Forum: LIVE PLC Questions And Answers October 1st, 2018, 04:25 PM
Replies: 18
Views: 480
Posted By goghie
GX Developer is completely different software and...

GX Developer is completely different software and it is fully compatible with all Windows I was using. For PLCs which do not have letter X after letter F you would need old Medoc application. However...
Forum: LIVE PLC Questions And Answers October 1st, 2018, 10:38 AM
Replies: 18
Views: 480
Posted By goghie
Lads maybe you know how to start it, but my Win10...

Lads maybe you know how to start it, but my Win10 informs me that app can't run on my PC. I've tried Win95 compatibility, but I think it is due to 64bit Windows.
Forum: LIVE PLC Questions And Answers October 1st, 2018, 08:26 AM
Replies: 18
Views: 480
Posted By goghie
No it is not possible. Medoc is true DOS...

No it is not possible. Medoc is true DOS application.
Forum: LIVE PLC Questions And Answers October 1st, 2018, 03:38 AM
Replies: 4
Views: 422
Posted By goghie
You can try with ABB. B&R is bought by them last...

You can try with ABB. B&R is bought by them last year.
Forum: LIVE PLC Questions And Answers September 26th, 2018, 07:59 AM
Replies: 20
Views: 710
Posted By goghie
With lot of PLCs you can't start rung without...

With lot of PLCs you can't start rung without some contact or operation that returns TRUE or FALSE value, so in Somachine there is LD 1("SHORT") - it's something like Always ON.
Forum: LIVE PLC Questions And Answers September 25th, 2018, 07:42 PM
Replies: 20
Views: 710
Posted By goghie
%MW and %MD memory ranges are overlapping... for...

%MW and %MD memory ranges are overlapping... for example %MD0 and %MW0 are pointing to same memory location. %MD0 takes %MW0 and %MW1, %MD1 takes %MW1 and %MW2, %MD2 takes %MW2 and %MW4...
Forum: LIVE PLC Questions And Answers September 12th, 2018, 06:26 AM
Replies: 4
Views: 294
Posted By goghie
Judging it by the look it is Yaskawa J1000 or...

Judging it by the look it is Yaskawa J1000 or similar. Check if it is and than I can help you.
Forum: LIVE PLC Questions And Answers September 8th, 2018, 03:55 PM
Replies: 38
Views: 10,959
Posted By goghie
Maybe I can be of help, but I don't know...

Maybe I can be of help, but I don't know Spanish... I've understood what did you wrote, because of similarities Whit other languages I speak...
Showing results 1 to 25 of 259

 
Forum Jump

All times are GMT -5. The time now is 12:22 AM.


.