Forum: LIVE PLC Questions And Answers August 16th, 2018, 08:05 PM
Replies: 15
Views: 699
Posted By kalabdel
As helpful as this thread is it is a title...

As helpful as this thread is it is a title confusing.

To my knowledge ST (Structured Text)= SCL (Structured Control Language) = Pascal (close enough) <> assembly language. I was unfortunate...
Forum: LIVE PLC Questions And Answers August 15th, 2018, 07:50 PM
Replies: 15
Views: 699
Posted By kalabdel
Computer language that is similar to ST as in...

Computer language that is similar to ST as in Structured Text, SCL in siemens world? It's basically Pascal, learn that and you're on your way. I wish I could program in SCL/ST all the time as it is...
Forum: LIVE PLC Questions And Answers August 14th, 2018, 09:25 PM
Replies: 11
Views: 175
Posted By kalabdel
Removing and reconnecting a node affects its...

Removing and reconnecting a node affects its communication with the PLC in exactly the way the programmer designed it to.
If you don't have access to the program, find out if there is/are alarms on...
Forum: LIVE PLC Questions And Answers August 13th, 2018, 09:58 AM
Replies: 8
Views: 218
Posted By kalabdel
The monitored snapshots in your first post, we're...

The monitored snapshots in your first post, we're they taken from the live CPU or a simulation?

You said it was a close call, was the software just deployed or has it been working for a while?
...
Forum: LIVE PLC Questions And Answers August 12th, 2018, 03:25 PM
Replies: 8
Views: 218
Posted By kalabdel
The start values are as you stated but are the...

The start values are as you stated but are the tags being used somewhere that the values are changed?
Forum: LIVE PLC Questions And Answers August 12th, 2018, 01:42 PM
Replies: 8
Views: 218
Posted By kalabdel
Can you change the Mina and Max display format of...

Can you change the Mina and Max display format of the monitored values to decimal and see if those are the values you intended. They're out to lunch.
Forum: LIVE PLC Questions And Answers August 7th, 2018, 04:04 AM
Replies: 6
Views: 222
Posted By kalabdel
It supports v4 but he would have to install an HSP

It supports v4 but he would have to install an HSP
Forum: LIVE PLC Questions And Answers August 2nd, 2018, 01:05 AM
Replies: 4
Views: 161
Posted By kalabdel
This is the first I've ever heard of "Julian...

This is the first I've ever heard of "Julian Date" :yeah:
What application is this for?
Forum: LIVE PLC Questions And Answers July 22nd, 2018, 08:47 PM
Replies: 3
Views: 245
Posted By kalabdel
What JRW asked and which version of TIA 14, I...

What JRW asked and which version of TIA 14, I *think* the with the basic version yo have access only to S7-1200.
Forum: LIVE PLC Questions And Answers July 21st, 2018, 12:16 PM
Replies: 4
Views: 330
Posted By kalabdel
Thanks Bob. I'm not sure we're talking about the...

Thanks Bob. I'm not sure we're talking about the same window. I am referring to the little window I circled in red. IS that also a memory window? I am starting to think it's a CX bug as I can not get...
Forum: LIVE PLC Questions And Answers July 20th, 2018, 09:43 AM
Replies: 4
Views: 330
Posted By kalabdel
Thanks Bob. It pops up when it wants to and it...

Thanks Bob. It pops up when it wants to and it doesn't display anything of value and though it looks resizeable I could not resize it. And after reading your reply I went back to look for it and...
Forum: LIVE PLC Questions And Answers July 19th, 2018, 09:45 AM
Replies: 4
Views: 330
Posted By kalabdel
CX-Programmer Data Monitor

Hello everyone,

What is this little window for?

Thanks
Forum: LIVE PLC Questions And Answers July 13th, 2018, 01:43 PM
Replies: 7
Views: 479
Posted By kalabdel
It turns out uploading parameters is not possible...

It turns out uploading parameters is not possible which means the address mapping of existing devices will have to be derived from the program.
Forum: LIVE PLC Questions And Answers July 13th, 2018, 11:15 AM
Replies: 7
Views: 479
Posted By kalabdel
Got the cable, using cx-profibus I added a device...

Got the cable, using cx-profibus I added a device right clicked and selected Go Online or Upload Parameters and I keep getting and error message "No Device Assignment" ! What does that mean?

...
Forum: LIVE PLC Questions And Answers July 12th, 2018, 10:03 AM
Replies: 10
Views: 369
Posted By kalabdel
Thanks guys. I am heading back today for a second...

Thanks guys. I am heading back today for a second look. The error has to do with I/O but I forgot to take a screenshot or it and will do that later.
The power supply is P2 120VAC to 24VDV and the...
Forum: LIVE PLC Questions And Answers July 11th, 2018, 10:47 PM
Replies: 10
Views: 683
Posted By kalabdel
If you are able to connect then you should be...

If you are able to connect then you should be able to download the program I think with .exob extension and decompile in the software. I had the same issue last year and Keith helped me through it.
Forum: LIVE PLC Questions And Answers July 11th, 2018, 10:18 PM
Replies: 10
Views: 369
Posted By kalabdel
SLC500 CUP power flicker

Hello everyone,

I have a SLC 5/03 with two racks, the first with 10 I/Os and the second with 12. The CPU intermittently restarts looking like it lost power . It's very quick but enough to reset...
Forum: LIVE PLC Questions And Answers July 9th, 2018, 06:03 PM
Replies: 1
Views: 187
Posted By kalabdel
Found it. Thanks

Found it. Thanks
Forum: LIVE PLC Questions And Answers July 9th, 2018, 05:51 PM
Replies: 1
Views: 187
Posted By kalabdel
Slc 500/03 battery replacement

Where is the battery located ? Is it on the left side of the cpu hidden by the power supply?

Thanks
Forum: LIVE PLC Questions And Answers July 7th, 2018, 01:03 AM
Replies: 10
Views: 683
Posted By kalabdel
I believe the USB is done only with a USB stick...

I believe the USB is done only with a USB stick not direct connection to PC. The procedure is somewhere out there in one of the manuals.
...
Forum: LIVE PLC Questions And Answers July 1st, 2018, 04:26 PM
Replies: 7
Views: 479
Posted By kalabdel
Thanks Bob. Here's a pic of the I/O. Slot #5 had...

Thanks Bob. Here's a pic of the I/O. Slot #5 had the RPOFIBUS master (I'm not user why it appears as Analog module as I have pictures of the hardware and it is definitely in that spot.)

From the...
Forum: LIVE PLC Questions And Answers July 1st, 2018, 12:09 PM
Replies: 7
Views: 479
Posted By kalabdel
Thanks Gary. I did review those two manual and ...

Thanks Gary. I did review those two manual and and two more for two days and couldn't find any of the memory areas that could be allocated based on the unit number anywhere in the code.
I'm...
Forum: LIVE PLC Questions And Answers July 1st, 2018, 03:49 AM
Replies: 7
Views: 479
Posted By kalabdel
C200HS memory mapping for PROFIBUS master

Hello everyone,

I have a copy of a program with very few named tags and no comments, which is typical. I have been trying to find out which memory is mapped to the PROFIBUS master PRM21 and can't...
Forum: LIVE PLC Questions And Answers July 1st, 2018, 03:30 AM
Replies: 26
Views: 1,647
Posted By kalabdel
I second Wiha, I have quite a bit of their tool...

I second Wiha, I have quite a bit of their tool and have been very happy with them.
Forum: LIVE PLC Questions And Answers June 29th, 2018, 01:51 PM
Replies: 0
Views: 186
Posted By kalabdel
OMRON C200HW-PRM21 communication cable

Hello guys,

I need to change the configuration on an C200HW-PRM21
PROFIBUS-DP Master Unit and looking communication cable. Any one knows where to get one? Is there another way to configure the...