You are not registered yet. Please click here to register!


 
 
plc storereviewsdownloads
This board is for PLC Related Q&A ONLY. Please DON'T use it for advertising, etc.
 
Try our online PLC Simulator- FREE.  Click here now to try it.

---------->>>>>Get FREE PLC Programming Tips

New Here? Please read this important info!!!


Go Back   PLCS.net - Interactive Q & A > Search Forums

Showing results 1 to 20 of 20
Search took 0.00 seconds.
Search: Posts Made By: MHammer
Forum: LIVE PLC Questions And Answers March 13th, 2018, 02:01 AM
Replies: 3
Views: 592
Posted By MHammer
Thanks to both of you. Jeev, it's running...

Thanks to both of you.

Jeev, it's running normal on a Win8Pro and no VM. Thanks for the screenshot.

Geoff, it was on 100% and that's why it looks like that, so I put switched it to 125%...
Forum: LIVE PLC Questions And Answers March 12th, 2018, 07:29 AM
Replies: 3
Views: 592
Posted By MHammer
Unhappy FT View - Search and Replace window

I have this problem with the Find & Replace function i FT View. I am not able to see the whole window. I do not know what to do, but if someone could attach a screenshot of the correct window in this...
Forum: LIVE PLC Questions And Answers February 21st, 2018, 02:45 AM
Replies: 10
Views: 905
Posted By MHammer
In addition to #8

In addition to #8
Forum: LIVE PLC Questions And Answers February 21st, 2018, 02:41 AM
Replies: 10
Views: 905
Posted By MHammer
Talking I've got another update to this. In RUNG 7,...

I've got another update to this. In RUNG 7, there's used a DAY_PLC tag but in the STAMP section, which results in an error (value 0) when the two dates is in February resulting it comparing DAY_PLC...
Forum: LIVE PLC Questions And Answers February 16th, 2018, 01:52 AM
Replies: 2
Views: 572
Posted By MHammer
That did it :) Thanks Steve

I haven't used that one before. Thank you Steve. I managed to find it in Global Connections and Macro 1.

:yeah:

//Hammer
Forum: LIVE PLC Questions And Answers February 15th, 2018, 07:03 AM
Replies: 2
Views: 572
Posted By MHammer
Question Expression ERROR in HMI

Does anyone know where I can find this ERROR? I've search almost everywhere in FTView and can't seem to find the TAG it's trying to find. :bawling:

The TAG is none existing in the PLC.

Thanks ...
Forum: LIVE PLC Questions And Answers January 31st, 2018, 10:37 AM
Replies: 10
Views: 905
Posted By MHammer
Talking I had encoutered an error that meant if the...

I had encoutered an error that meant if the difference between PLC_Time and Stamp_Time was under 24H it added 24 hours to the total elapsed time, thus showing an incorrect value.

In the AOI in...
Forum: LIVE PLC Questions And Answers January 31st, 2018, 04:53 AM
Replies: 10
Views: 905
Posted By MHammer
Do you by any chance know if the AOI I used is...

Do you by any chance know if the AOI I used is based on a 24Hour clock or 12Hour?
The PLC is located in EU with the 24Hour clock.
Forum: LIVE PLC Questions And Answers January 31st, 2018, 02:23 AM
Replies: 10
Views: 905
Posted By MHammer
Thanks to both of you. I was able to use the...

Thanks to both of you. I was able to use the "Elasped Time Add-on Instruction...
Forum: LIVE PLC Questions And Answers January 30th, 2018, 09:39 AM
Replies: 10
Views: 905
Posted By MHammer
Thanks you two. I will look into your answers and...

Thanks you two. I will look into your answers and report back if I get it working.

//Hammer
Forum: LIVE PLC Questions And Answers January 30th, 2018, 09:08 AM
Replies: 10
Views: 905
Posted By MHammer
Compare TimeStamp with WallClockTime

Hi. I hope you could give me some advise here.



I'm ongoing with a project which has many plates that are glued individual and put into a storage shelf. When a part is glued and put into...
Forum: LIVE PLC Questions And Answers January 29th, 2018, 08:12 AM
Replies: 4
Views: 443
Posted By MHammer
Haha :) So I'm guessing you do not have an answer...

Haha :) So I'm guessing you do not have an answer to my problem?
Forum: LIVE PLC Questions And Answers January 29th, 2018, 07:34 AM
Replies: 4
Views: 443
Posted By MHammer
Lightbulb FactoryTalk View NOT RSlogx 5k as mentioned.

I'm a retard, my problem is in Factory Talk View and NOT RSLogix as i wrote......

My FCView version is
Release no.: 9.00.00 (CPR 9SR 9)
Build no.: 241
Forum: LIVE PLC Questions And Answers January 29th, 2018, 07:19 AM
Replies: 4
Views: 443
Posted By MHammer
RSLogix 5k - Search not showing alle

Hi

I have a problem with the search function in Factory Talk View. The menu is not showing everything. See attached image.

I'm missing out on some properties that maybe could come in handy...
Forum: LIVE PLC Questions And Answers December 14th, 2017, 11:47 PM
Replies: 12
Views: 1,467
Posted By MHammer
Smile I'll try enableing Quick Key :)

Thank you, for all the responses. I've tried looking into the Quick Key funtion, but i drove me kind of insane at first. But maybe I should try to enable it again.

//Hammer :congrats:
Forum: LIVE PLC Questions And Answers December 13th, 2017, 02:49 AM
Replies: 12
Views: 1,467
Posted By MHammer
Question RSLogix 5k - Locking top toolbars

Hi everyone who's reading this. :)

I have a tendecy to move around with the toolbars in RSLogix 5000, when I have to make a fast function draw into to the ladder.
Is there any way to lock them...
Forum: LIVE PLC Questions And Answers September 22nd, 2017, 06:43 AM
Replies: 12
Views: 1,557
Posted By MHammer
Phrog30, okay I'll have to live with that. As of...

Phrog30, okay I'll have to live with that. As of now, my program is not that big that it would make a significant difference, but I just wanted to be a little prepared when the day comes :)

Thanks...
Forum: LIVE PLC Questions And Answers September 22nd, 2017, 06:12 AM
Replies: 12
Views: 1,557
Posted By MHammer
Yes, it is working, but sadly not the solution...

Yes, it is working, but sadly not the solution I'm looking for. But Ctrl+G let's me search for the specific line.

//Hammer
Forum: LIVE PLC Questions And Answers September 22nd, 2017, 03:43 AM
Replies: 12
Views: 1,557
Posted By MHammer
There must be a way to enable it. I know that you...

There must be a way to enable it. I know that you can click on the warning/error and then see it right away, but it would be nice to see all line/row numbers.

Thanks for the answer.

//Hammer
Forum: LIVE PLC Questions And Answers September 22nd, 2017, 02:10 AM
Replies: 12
Views: 1,557
Posted By MHammer
RSLogix 5k Structured Text Editor - Show line no.

Hi

I'm working on a project in structured text in RSLogix 5k.
When I verify my program it shows the errors and warnings in the buttom of my screen.
Each with a line number. "ERROR: Line 76, ;...
Showing results 1 to 20 of 20

 
Forum Jump

All times are GMT -5. The time now is 01:02 PM.


.