Search: Posts Made By: 02js4130
Forum: LIVE PLC Questions And Answers October 23rd, 2018, 04:32 AM
Replies: 10
Views: 252
Posted By 02js4130
Thank you for all you reply's. I would...

Thank you for all you reply's.

I would ideally be looking at using a zebra as currently the factory is using zebra zt420 for interfacing with pc's

as in a previous post geniusintraining ponted...
Forum: LIVE PLC Questions And Answers October 22nd, 2018, 10:23 AM
Replies: 10
Views: 252
Posted By 02js4130
Thanks for your reply. I assume then that...

Thanks for your reply.

I assume then that the printer holds a preloaded ZPL (if a zebra printer) file in the printers memory with the label format ect.

who holds the labels information e.g...
Forum: LIVE PLC Questions And Answers October 22nd, 2018, 09:45 AM
Replies: 10
Views: 252
Posted By 02js4130
Thanks for the info. I am also starting to...

Thanks for the info.

I am also starting to realise that interfacing the PLC and printer may be more complex than first thought.

Does anyone have any knowledge on interfacing a PLC and PC?

I...
Forum: LIVE PLC Questions And Answers October 22nd, 2018, 09:18 AM
Replies: 10
Views: 252
Posted By 02js4130
Thank you for your suggestion. How do you...

Thank you for your suggestion.

How do you find programming these? and are their simple communications for the PLC to printer?
Forum: LIVE PLC Questions And Answers October 22nd, 2018, 08:47 AM
Replies: 10
Views: 252
Posted By 02js4130
Allen brandley and printers

Hi,

I am required to link up a Allen bradley micrologix PLC with a label printer to allow automated requests.

Does anyone have any experience of this ? and what tort of printer to be using or...
Forum: LIVE PLC Questions And Answers November 15th, 2017, 11:16 AM
Replies: 4
Views: 359
Posted By 02js4130
Msg function micrologix

Hi,

i have both a ML1400 and a ML1500 and i would like to make a network using DH485. The ML1500 Will be the main plc with the program and i would like to use the ML1400 to just store the recipie...
Forum: LIVE PLC Questions And Answers November 15th, 2017, 04:10 AM
Replies: 1
Views: 308
Posted By 02js4130
Data tables stored external to plc?

Hi,

i have a project where a simple step by step program has been created for a batching process eg.a recipie is selected and then an ingredient is displayed on HMI and the weight ect, the...
Forum: LIVE PLC Questions And Answers February 17th, 2017, 11:12 AM
Replies: 1
Views: 1,062
Posted By 02js4130
Siemens s7-300 ppi connection masters detected

HI,

I am new to Siemens and having difficulties connection to the S7-300. I have recently been connecting to the 200 without a problem so assumed that establishing communications with the 300...
Forum: LIVE PLC Questions And Answers January 26th, 2017, 10:22 AM
Replies: 1
Views: 858
Posted By 02js4130
[b]siemens hmi[/b]

HI,

I currently have an issue with SIEMENS hardware with which i need help!

I have a Siemens COROS OP 35 running a thermoglide which is old and dated now and costly to replace in the event of...
Forum: LIVE PLC Questions And Answers January 26th, 2017, 09:29 AM
Replies: 2
Views: 860
Posted By 02js4130
Siemens coros op 35 alternative

HI,

I currently have an issue with SIEMENS hardware with which i need help!

I have a Siemens COROS OP 35 running a thermoglide which is old and dated now and costly to replace in the event of...
Forum: LIVE PLC Questions And Answers April 16th, 2015, 09:45 AM
Replies: 3
Views: 599
Posted By 02js4130
Thank you for the reply!! yes your right we are...

Thank you for the reply!! yes your right we are using a converter, only because originally we were connected direct into the com port on the PC but for some reason that stopped working and will not...
Forum: LIVE PLC Questions And Answers April 16th, 2015, 05:43 AM
Replies: 3
Views: 599
Posted By 02js4130
Instruction help!!

Hi,

I am using a AB Micrologix 1500 linked too a computer using RS232 and some OPC software.

We keep having problems where the communications drop out and were wondering is there is a system...
Forum: LIVE PLC Questions And Answers March 19th, 2015, 06:58 AM
Replies: 0
Views: 523
Posted By 02js4130
[b]micrologix data logging[/b]

Hi,

I am wondering how too address string data when using the data logger function in micrologix 1500.

I would like too log just a few back up records using the function but im finding it hard...
Forum: LIVE PLC Questions And Answers March 18th, 2015, 05:29 AM
Replies: 5
Views: 1,017
Posted By 02js4130
Thanks guys for your help, i will try turning the...

Thanks guys for your help, i will try turning the port on and off but it fn to i will stick with running it throught the USB converter
Forum: LIVE PLC Questions And Answers March 17th, 2015, 12:30 PM
Replies: 5
Views: 1,017
Posted By 02js4130
Hi harryting, No the com port issue hasn't...

Hi harryting,

No the com port issue hasn't been resolved i am finding it hard to get an answer.

RsLinx has been running using the COM1 for months and just dropped out, and now the port cannot...
Forum: LIVE PLC Questions And Answers March 17th, 2015, 08:39 AM
Replies: 5
Views: 1,017
Posted By 02js4130
RsLinx and communication error

Hi all,

currently i have created and running a batching system for making muesli, using a micrologix 1500 and Rslinx classic single node.

I am using Microsoft XP professional SP3 and a piece of...
Forum: LIVE PLC Questions And Answers March 6th, 2015, 06:29 AM
Replies: 3
Views: 865
Posted By 02js4130
ahh ok i did wonder this when i was researching. ...

ahh ok i did wonder this when i was researching.

Is there any way of increasing the memory? or would i have too chance processors completely?
Forum: LIVE PLC Questions And Answers March 6th, 2015, 06:05 AM
Replies: 3
Views: 865
Posted By 02js4130
Adding additional memory?

Hi,

I have encountered a situation where the PLC ( Micrologix 1500 LRP) has reached its memory limit, so i have done some research and found out that there is additional memory available in the...
Forum: LIVE PLC Questions And Answers January 28th, 2015, 04:03 AM
Replies: 4
Views: 1,036
Posted By 02js4130
thanks for the reply's! much help. I have...

thanks for the reply's! much help.

I have solved the problem using your methods of inputting via the data table and it works a treat.

Also learnt something new :)
Forum: LIVE PLC Questions And Answers January 26th, 2015, 11:45 AM
Replies: 4
Views: 1,036
Posted By 02js4130
Ascii strings and programming constants

HI,

i am having trouble trying to differentiate between 2 strings using just integers, so i need to do a string compare and use the letters to differentiate and this will work perfect. The...
Forum: LIVE PLC Questions And Answers September 25th, 2014, 11:40 AM
Replies: 1
Views: 679
Posted By 02js4130
Addressing ascii stings suffix/prefix

HI,

I am currently working on a project using a micrologix 1500 and a data logging/acquisition software called orchestrator.

I am using RSLINX as the OPC server to allow orchestarator to be...
Forum: LIVE PLC Questions And Answers July 24th, 2014, 11:29 AM
Replies: 6
Views: 1,414
Posted By 02js4130
Thank you for both of the reply's. They have been...

Thank you for both of the reply's. They have been much needed help.
The micrologix 1200 and the slc 4/05 are currently available for use but that does not mean that they have to be used.

A follow...
Forum: LIVE PLC Questions And Answers July 24th, 2014, 09:41 AM
Replies: 6
Views: 1,414
Posted By 02js4130
Exclamation Multiple communication protocols

Hi,
I am wondering if anyone could help me!!! This may be an obvious question that i am missing the point to but its worth asking.

I am creating a new system using a micrologix 1200 or maybe a...
Forum: LIVE PLC Questions And Answers July 3rd, 2014, 04:07 AM
Replies: 9
Views: 1,492
Posted By 02js4130
hello again, Thank you four your help so...

hello again,

Thank you four your help so far much apreciated!!! i shall try the Hyper Terminal method first and see exactally what need to be sent and received ect.

Here is the link for the...
Forum: LIVE PLC Questions And Answers July 2nd, 2014, 09:26 AM
Replies: 9
Views: 1,492
Posted By 02js4130
I should probably add that we are looking for two...

I should probably add that we are looking for two way communication between the plc and pr444zv. our information states that if the host sends "0CR" the pr44 sends "grossweightCR". it is prooving...
Showing results 1 to 25 of 26

 