Search: Posts Made By: John Morris
Forum: LIVE PLC Questions And Answers September 12th, 2018, 06:58 AM
Replies: 5
Views: 306
Posted By John Morris
Thank you sir and...Good Luck to you in the...

Thank you sir

and...Good Luck to you in the coming days.
Forum: LIVE PLC Questions And Answers September 12th, 2018, 06:22 AM
Replies: 5
Views: 306
Posted By John Morris
Thank you for the reply. I will change the...

Thank you for the reply.

I will change the values.
Forum: LIVE PLC Questions And Answers September 11th, 2018, 11:01 AM
Replies: 5
Views: 306
Posted By John Morris
Ftv me 8 alarm triggers

Morning

I have created an alarm list in FTV ME, this time i used DINTs to bank certain alarm together such as individual tank alarms or system alarms like low air pressure or low water flow.
...
Forum: LIVE PLC Questions And Answers September 10th, 2018, 04:18 PM
Replies: 34
Views: 1,896
Posted By John Morris
48871 No it doesn't help with the wiring put...

48871

No it doesn't help with the wiring put cuts down alot on opening the door and having to suit up
Forum: LIVE PLC Questions And Answers August 11th, 2018, 09:18 AM
Replies: 105
Views: 6,725
Posted By John Morris
Thomas, these were play-on-words, farces, Jokes. ...

Thomas, these were play-on-words, farces, Jokes.

I use them mainly to embarrass the new engineers. After they watch them with serious faces and try to explain to each other what a "Dingle Alarm"...
Forum: LIVE PLC Questions And Answers August 10th, 2018, 02:54 PM
Replies: 105
Views: 6,725
Posted By John Morris
2016 https://www.youtube.com/watch?v=u4ILnWpi8XY ...

2016 https://www.youtube.com/watch?v=u4ILnWpi8XY

But knot as good.

Owe you a new monitor too?
Forum: LIVE PLC Questions And Answers August 10th, 2018, 02:38 PM
Replies: 17
Views: 1,027
Posted By John Morris
+1

+1
Forum: LIVE PLC Questions And Answers August 10th, 2018, 02:34 PM
Replies: 4
Views: 409
Posted By John Morris
Yes Sir. I thought of that but the error code are...

Yes Sir. I thought of that but the error code are a manual input.

The only automatic thing about this part of the program is the sonic generators produce a generic on/off signal alerting an...
Forum: LIVE PLC Questions And Answers August 10th, 2018, 11:20 AM
Replies: 105
Views: 6,725
Posted By John Morris
I am surprised no one has mention the old...

I am surprised no one has mention the old reliable

"Rockwell Retro Encabulator" 1996

https://www.youtube.com/watch?v=RXJKdh1KZ0w

and "Turbo Encabulator" 1988
...
Forum: LIVE PLC Questions And Answers August 10th, 2018, 06:35 AM
Replies: 4
Views: 409
Posted By John Morris
Thank you for your response Jeev Right now...

Thank you for your response Jeev

Right now there are 14 error codes. Never have tried 14 on a multi-state. that would keep everything on the HMI wouldn't it. I'll check the HMI for the PDF option....
Forum: LIVE PLC Questions And Answers August 9th, 2018, 11:59 AM
Replies: 4
Views: 409
Posted By John Morris
Ftv me 8 call screen

Oh alrighty then. This should get interesting.

Using FTV ME 8. ( PLC l33er , hmi plus 7)

I have a list of error codes E 01 thru E whatever.

My Idea was to navigate to screen 8 ( Error code...
Forum: LIVE PLC Questions And Answers August 8th, 2018, 08:42 AM
Replies: 9
Views: 494
Posted By John Morris
+1

+1
Forum: LIVE PLC Questions And Answers July 31st, 2018, 06:57 AM
Replies: 15
Views: 815
Posted By John Morris
https://www.winford.com/products/mjjsgf.php ...

https://www.winford.com/products/mjjsgf.php

PERFECT, thank you Genius
Forum: LIVE PLC Questions And Answers July 30th, 2018, 04:15 PM
Replies: 15
Views: 815
Posted By John Morris
It's all TE connectors, Last job we did, we...

It's all TE connectors,

Last job we did, we spent four days on site connecting the control cabinet to the machine.

This time the bright idea was to cable EVERYTHING, turning it into plug and...
Forum: LIVE PLC Questions And Answers July 30th, 2018, 03:50 PM
Replies: 15
Views: 815
Posted By John Morris
Hmm The cabling we were thinking of using is...

Hmm

The cabling we were thinking of using is a 22 gauge with 8 twisted pairs, each foil shielded with a drain wire topped off with the annoying cellophane wrap

If I skip the terminal blocks and...
Forum: LIVE PLC Questions And Answers July 30th, 2018, 02:55 PM
Replies: 15
Views: 815
Posted By John Morris
Only cause i've never done it before

Rookie question

I want to run Ethernet from PLC cabinet to HMI cabinet some 27 feet away.

On this project we are using cabling to connect remote devices

The idea was to break out the...
Forum: LIVE PLC Questions And Answers July 24th, 2018, 03:44 PM
Replies: 36
Views: 1,716
Posted By John Morris
Sapper Your the best. tytytytytytytyty. ...

Sapper

Your the best. tytytytytytytyty.

Puzzle complete

Thank you all for your time and attention in helping me solve this.

Dan, sorry if I hijacked you post, You have my sincerest...
Forum: LIVE PLC Questions And Answers July 24th, 2018, 02:39 PM
Replies: 36
Views: 1,716
Posted By John Morris
I have that downloaded already. Thank you. ...

I have that downloaded already. Thank you.

That's a gazinta I need a gozouta. ( What my third year professor use to call inputs and outputs.)

How do you write the protocol inside the PLC to...
Forum: LIVE PLC Questions And Answers July 24th, 2018, 02:13 PM
Replies: 36
Views: 1,716
Posted By John Morris
https://danstips.files.wordpress.com/2014/06/lesma...

https://danstips.files.wordpress.com/2014/06/lesman-bakers-dozen-tips-modbus-rtu-honeywell-rm7800s.pdf

I ran across that paper about two months ago searching out Modbus protocols.

Ya know what,...
Forum: LIVE PLC Questions And Answers July 24th, 2018, 01:20 PM
Replies: 36
Views: 1,716
Posted By John Morris
Sorry Sparkie It was my bad attempt at two...

Sorry Sparkie

It was my bad attempt at two bits and an output.

We will probably end up using a small compact logix. I have not made the design layout yet. just know it's going to be in rs5000...
Forum: LIVE PLC Questions And Answers July 24th, 2018, 01:10 PM
Replies: 24
Views: 1,752
Posted By John Morris
In Idec using the counter it has thee inputs,...

In Idec using the counter it has thee inputs, trigger, pulse, and a bit to hold it high or low for up count or down count.

I always labeled it "Doesn't do a dam thing".
Forum: LIVE PLC Questions And Answers July 24th, 2018, 01:03 PM
Replies: 36
Views: 1,716
Posted By John Morris
Boneless it's a Honeywell It does, thank you...

Boneless it's a Honeywell

It does, thank you Sparkie

Harry, Thank you, that is a world of information I will use.

And all, Please forgive this derpish question
...
Forum: LIVE PLC Questions And Answers July 24th, 2018, 10:51 AM
Replies: 36
Views: 1,716
Posted By John Morris
Ok I get that, but what would it look like...

Ok

I get that, but what would it look like in say rs5000. Would it be as simple as a MSG instruction.

And if there is an alarm in the burner control? Since communication is initiated only in...
Forum: LIVE PLC Questions And Answers July 23rd, 2018, 02:02 PM
Replies: 36
Views: 1,716
Posted By John Morris
I understand where you are coming from Dan. How...

I understand where you are coming from Dan. How to begin.

I have read all the links (many I have seen before) and I understand much better now how Modbus is supposed to work. The fundamentals.
...
Forum: LIVE PLC Questions And Answers July 20th, 2018, 03:26 PM
Replies: 114
Views: 12,618
Posted By John Morris
Makes sense. Does the hole move or dose the...

Makes sense. Does the hole move or dose the electron.

Voltage = cars, Current = speed.

When they are too close it causes friction and they all slow down, resistors.

When one idiot texts...