Showing results 1 to 25 of 68
Search took 0.04 seconds.
Search: Posts Made By: psychosunshine
Forum: LIVE PLC Questions And Answers October 28th, 2018, 08:31 PM
Replies: 2
Views: 104
Posted By psychosunshine
VersaView Repair or Replacement?

I have a VersaView 1500P (6181-15TSXP Series E) that has a failed hard drive (2.5 inch SATA). I could get a new hard drive for it. Although, I do not know how much work I'm going to have to put...
Forum: LIVE PLC Questions And Answers October 26th, 2018, 02:36 PM
Replies: 21
Views: 995
Posted By psychosunshine
You can power the main board from any F7 VFD. I...

You can power the main board from any F7 VFD. I could power it up on another working F7 VFD. Just to get the parameters. It sounds like the programming in the F7 is quite creative, in order to get...
Forum: LIVE PLC Questions And Answers October 26th, 2018, 04:54 AM
Replies: 21
Views: 995
Posted By psychosunshine
Yes, I think an A1000 would be a great choice. ...

Yes, I think an A1000 would be a great choice.


And, as long as the main board did not fail on the old F7 VFD. It is easy to hook it up and get the parameters out of it.


Do you know what...
Forum: LIVE PLC Questions And Answers October 26th, 2018, 04:45 AM
Replies: 1
Views: 107
Posted By psychosunshine
Adding Flex I/O to Studio 5000 Project

I am adding some Flex I/O ethernet nodes to an existing project at a plant.


I've already set my IP addresses. And they show up with my IP scanner.


I have 2 16pt digital input modules and 2...
Forum: LIVE PLC Questions And Answers October 11th, 2018, 10:24 AM
Replies: 1
Views: 125
Posted By psychosunshine
Obsolete Kinetix Servo Motor

I am using an mpl-b220t-vj44aa on an older machine. Does anyone know if I can replace it with an mpl-b220t-vj74aa?


The mpl-b220t-vj74aa is still available as a new motor from my local AB...
Forum: LIVE PLC Questions And Answers September 13th, 2018, 11:27 PM
Replies: 36
Views: 5,142
Posted By psychosunshine
I had the exact same issue with a 1756-L72 PLC. ...

I had the exact same issue with a 1756-L72 PLC. I could see the IP in RSLinx Classic Version 3.90.00. But, I could not drill down to the backplane or CPU. I could ping the PLC. I could even load...
Forum: LIVE PLC Questions And Answers September 4th, 2017, 09:22 PM
Replies: 0
Views: 297
Posted By psychosunshine
PARKER-CTC Interact HMI Software - LRP File

I am taking over a CTC Interact project. All I have to start with is the LRP file. I do not know what version it was written in.

It was done about a year ago.

What I need to know, is what...
Forum: LIVE PLC Questions And Answers November 10th, 2016, 08:25 AM
Replies: 7
Views: 1,431
Posted By psychosunshine
Yeah, I thought about that. Although, it's a...

Yeah, I thought about that. Although, it's a printing press.
Forum: LIVE PLC Questions And Answers November 10th, 2016, 07:37 AM
Replies: 7
Views: 1,431
Posted By psychosunshine
Siemens S5 Programming Software

I have a customer that wants to upload a PLC program from a Siemens S5 PLC (115U CPU942).

It's a DB15 Female connector on the CPU.

What software and cable adapter would you guys recommend?
...
Forum: LIVE PLC Questions And Answers July 12th, 2016, 08:08 AM
Replies: 1
Views: 241
Posted By psychosunshine
Siemens S7-200 with VFDs Setup

I have 4 Siemens VFDs connected to an S7-200. Two of them are Micromaster and the other two are Micromaster 420 VFDs. How can I see in this PLC program how they are addressed? I am not that...
Forum: LIVE PLC Questions And Answers July 1st, 2016, 01:24 PM
Replies: 12
Views: 1,589
Posted By psychosunshine
Can anyone convert this project so that it can be...

Can anyone convert this project so that it can be downloaded into an HMI with ProSave?

ProSave will not open this project file?
Forum: LIVE PLC Questions And Answers June 17th, 2016, 05:51 PM
Replies: 12
Views: 1,589
Posted By psychosunshine
What I will need to do is to upload this project...

What I will need to do is to upload this project into a new (used) OP17 with ProSave (which uses a different file type) or I will have to use a new touchscreen HMI and convert or write from scratch...
Forum: LIVE PLC Questions And Answers June 17th, 2016, 05:47 PM
Replies: 12
Views: 1,589
Posted By psychosunshine
Yes! a PDF of the screens and the tag list if...

Yes! a PDF of the screens and the tag list if possible.

Is there a list of the tags and addresses that are attached to the F keys?
Forum: LIVE PLC Questions And Answers June 17th, 2016, 03:26 PM
Replies: 12
Views: 1,589
Posted By psychosunshine
Here is the project file... I have WinCC SP3...

Here is the project file...

I have WinCC SP3 upd3.

That's why I couldn't figure it out.
Forum: LIVE PLC Questions And Answers June 17th, 2016, 01:42 PM
Replies: 12
Views: 1,589
Posted By psychosunshine
I guess another option is to import this project...

I guess another option is to import this project into WinCC Flex. Does anyone know how to do that?
Forum: LIVE PLC Questions And Answers June 17th, 2016, 11:07 AM
Replies: 12
Views: 1,589
Posted By psychosunshine
Siemens ProTool Software for old OP17 Panel

Does anyone have the old ProTool software from Siemens?

I was wondering if someone could open a project for me or sell me the software. From Siemens it is obsolete.

I have a pdb file that I'd...
Forum: LIVE PLC Questions And Answers June 17th, 2016, 11:01 AM
Replies: 0
Views: 579
Posted By psychosunshine
Siemens ProTool Software for old OP17 Panel

Does anyone have the old ProTool software from Siemens?

I was wondering if someone could open a project for me or sell me the software. From Siemens it is obsolete.

I have a pdb file that I'd...
Forum: LIVE PLC Questions And Answers April 11th, 2016, 11:33 AM
Replies: 10
Views: 1,060
Posted By psychosunshine
I thought VM would be the answer. Now, I guess...

I thought VM would be the answer. Now, I guess I need to start learning how to use them.

Microsoft or VirtualBox?

I have Windows 7 64 bit
Forum: LIVE PLC Questions And Answers April 10th, 2016, 09:05 PM
Replies: 10
Views: 1,060
Posted By psychosunshine
Siemens Step 7 and RSLogix on same PC

My Windows 7 64 bit laptop has Step 7 on it.

I am going to do a Rockwell job tomorrow.

Do you know if there are any issues with installing RSLogix 500 or RSLogix 5000 on the same PC?

Thanks,...
Forum: LIVE PLC Questions And Answers September 4th, 2015, 12:47 PM
Replies: 0
Views: 425
Posted By psychosunshine
Hardware Config - You can only use IO devices in a PNIO syste, ERROR

Why am I getting this error?

I am trying to install a Turck module on this station.

This module is installed on several stations here with no issue.
Forum: LIVE PLC Questions And Answers August 18th, 2015, 02:51 PM
Replies: 3
Views: 1,127
Posted By psychosunshine
Step 7 Hardware Config Adding Module Error

I am trying to install an FVDO-P or an FVDO-P2 module into my hardware config in Siemens Step 7.

That is slot 5 of my module. But, when I try to install the module into that slot,...
Forum: LIVE PLC Questions And Answers August 13th, 2015, 08:27 AM
Replies: 2
Views: 840
Posted By psychosunshine
Step 7 5.5 SP3 Simatic Manager Zoom

Is there a way to zoom in, in Simatic Manager?

I have an extremely high resolution monitor (3200x1800) and it's hard to read.

I know that I can zoom in, in the ladder editor, and that helps a...
Forum: LIVE PLC Questions And Answers February 23rd, 2015, 07:09 AM
Replies: 4
Views: 753
Posted By psychosunshine
Siemens Step 7 Monitoring SF Indicator

Is there a way to monitor the error indicators of the PLC from Step 7 V5.5 SP3?
Forum: LIVE PLC Questions And Answers February 21st, 2015, 09:09 AM
Replies: 13
Views: 1,482
Posted By psychosunshine
What is the default IP address of a new S7-300?

What is the default IP address of a new S7-300?
Forum: LIVE PLC Questions And Answers February 20th, 2015, 07:54 AM
Replies: 13
Views: 1,482
Posted By psychosunshine
OK. The existing PLC is a 6ES7 315-2FJ14-0AB0 /...

OK. The existing PLC is a 6ES7 315-2FJ14-0AB0 / V3.2. And the new one is a 6ES7 317-2FK14-0AB0
Showing results 1 to 25 of 68

 