Posted By mmw
depends on the application ... the 1100 may be...

depends on the application ... the 1100 may be perfect for the job
Forum: LIVE PLC Questions And Answers October 27th, 2005, 10:11 AM
Replies: 7
Views: 1,813
Posted By mmw
I've put about 10 of them in service so far and...

I've put about 10 of them in service so far and have been very pleased with them. Only wish the processor name would show up in rslinx (instead of just the model number) ... would make my RSSql data...
Forum: LIVE PLC Questions And Answers March 8th, 2005, 07:14 AM
Replies: 148
Views: 12,533
Posted By mmw
yes, please! The ticker is my only interface to...

yes, please! The ticker is my only interface to the sane world!
Forum: LIVE PLC Questions And Answers February 28th, 2005, 07:20 AM
Replies: 148
Views: 12,533
Posted By mmw
did something happen to the ticker?

did something happen to the ticker?
Forum: LIVE PLC Questions And Answers February 18th, 2005, 09:50 AM
Replies: 7
Views: 6,411
Posted By mmw
problem resolved ... corrupt and some missing...

problem resolved ... corrupt and some missing backplane EDS files thanks again to all (Bw/D - you pointed me in the right direction)
Forum: LIVE PLC Questions And Answers February 18th, 2005, 07:33 AM
Replies: 7
Views: 6,411
Posted By mmw
Thanks for the responses guys. Let me address...

Thanks for the responses guys. Let me address what many of you have suggested ...

operaghost: the ethernet module is setting directly next to a controllogix processor in the chassis. Yes, I can...
Forum: LIVE PLC Questions And Answers February 17th, 2005, 03:53 PM
Replies: 7
Views: 6,411
Posted By mmw
RSLinx / Controllogix problem

My NT4.0 box running RSLinx 2.42.00 (build 18) will not allow me to browse past a 1756-ENBT module. I can "see" the ethernet module in RSWho, but when I click on the "+" to expand and drill into it,...
Forum: LIVE PLC Questions And Answers February 7th, 2005, 10:58 AM
Replies: 19
Views: 3,694
Posted By mmw
ok, thanks for the info regarding tag creation. ...

ok, thanks for the info regarding tag creation. what about creating new programs? and their subsequent scheduleing under the MainTask?
Forum: LIVE PLC Questions And Answers February 7th, 2005, 10:20 AM
Replies: 19
Views: 3,694
Posted By mmw
can you create new memory tags while the...

can you create new memory tags while the processor is running? I find the need to add some logic (to drive an InView display) to an existing application that's running out on the plant floor. Sho'...
Forum: LIVE PLC Questions And Answers February 3rd, 2005, 09:17 AM
Replies: 19
Views: 2,974
Posted By mmw
how about a 50/50 split? 50% of the final grade...

how about a 50/50 split? 50% of the final grade coming from "peers" and 50 % from the instructor. I've used that method before with decent results.

And depending on the instructor, his/her...
Forum: LIVE PLC Questions And Answers January 25th, 2005, 03:51 PM
Replies: 61
Views: 8,489
Posted By mmw
appears that the dastardly controllogix has...

appears that the dastardly controllogix has corrupted Allen's thinking ;)
Forum: LIVE PLC Questions And Answers January 25th, 2005, 09:25 AM
Replies: 18
Views: 6,087
Posted By mmw
The I/O config info to which you refer is just...

The I/O config info to which you refer is just documentation (for a PLC-5 system) and therefore has nothing to do with what's actually in the chassis or how it works.
Forum: LIVE PLC Questions And Answers December 17th, 2004, 07:59 AM
Replies: 15
Views: 23,418
Posted By mmw
I'm with Ken ... set up one bit and use xic and...

I'm with Ken ... set up one bit and use xic and xio as required. 'Course if it's confusing that
not "always off" = "always on", then back away slowly from the code.
Forum: LIVE PLC Questions And Answers December 9th, 2004, 01:37 PM
Replies: 30
Views: 5,631
Posted By mmw
well, "lately" = a few years back no way on...

well, "lately" = a few years back

no way on the phone # buddy
Forum: LIVE PLC Questions And Answers December 9th, 2004, 01:24 PM
Replies: 30
Views: 5,631
Posted By mmw
The last one I saw (and ran quickly away from)...

The last one I saw (and ran quickly away from) was in a power tool manufacturing facility in Arkansas ... still chugging along.

I expect the AB guys would refer a caller to someone with experience...
Forum: LIVE PLC Questions And Answers December 9th, 2004, 01:15 PM
Replies: 30
Views: 5,631
Posted By mmw
I wonder how many of us PLC-4 folks are out there.

I wonder how many of us PLC-4 folks are out there.
Forum: LIVE PLC Questions And Answers December 8th, 2004, 11:57 AM
Replies: 14
Views: 3,078
Posted By mmw
with or without the shields, it's still a mess. ...

with or without the shields, it's still a mess. Just wad it up in a ball of electrical tape ... that'll fix it up! :thumb:
Forum: LIVE PLC Questions And Answers December 8th, 2004, 09:40 AM
Replies: 14
Views: 3,078
Posted By mmw
good points about the node number, ron And...

good points about the node number, ron

And look on page 221 where they're adding the capacitor at the middle node for noise immunity. Easy to draw; not-so-easy to implement in the daisy-chain...
Forum: LIVE PLC Questions And Answers December 8th, 2004, 09:07 AM
Replies: 14
Views: 3,078
Posted By mmw
many things suggest otherwise, for example pub...

many things suggest otherwise, for example pub 1770-6.2.1 and an understanding of what's going on electrically on a real DH+ in the field
Forum: LIVE PLC Questions And Answers December 8th, 2004, 08:00 AM
Replies: 14
Views: 3,078
Posted By mmw
noise immunity

noise immunity
Forum: LIVE PLC Questions And Answers December 8th, 2004, 07:18 AM
Replies: 14
Views: 3,078
Posted By mmw
Actually, electrically, it's best to build a...

Actually, electrically, it's best to build a trunkline-dropline network. Much more robust than daisy-chaining. But since most don't understand the difference and daisy-chaining is easier, that's...
Forum: LIVE PLC Questions And Answers December 3rd, 2004, 10:21 AM
Replies: 51
Views: 7,764
Posted By mmw
mine came last week. Memphis, TN area now...

mine came last week. Memphis, TN area

now waiting for the golf balls :handball:
Forum: LIVE PLC Questions And Answers November 2nd, 2004, 10:18 AM
Replies: 5
Views: 1,688
Posted By mmw
msinclair beat me to the punch ... yes,...

msinclair beat me to the punch ...

yes, capture text in hyperterminal works (with the 1771-DB at least; that's a cousin to the 1746-BAS)

Of course you have to 'break' (ie stop) the running...
Forum: LIVE PLC Questions And Answers October 18th, 2004, 11:20 AM
Replies: 14
Views: 2,920
Posted By mmw
huh? :huh:

huh? :huh:
Forum: LIVE PLC Questions And Answers September 21st, 2004, 07:14 AM
Replies: 1
Views: 1,352
Posted By mmw
take a look at the "AppStart" command - it will...

take a look at the "AppStart" command - it will allow you to run programs external to RSView. Its use is straightforward.