Search: Posts Made By: Dravik
Forum: LIVE PLC Questions And Answers October 16th, 2018, 11:20 AM
Replies: 11
Views: 228
Posted By Dravik
Here's the one I use - Works great. ...

Here's the one I use - Works great.
https://pogostick.net/~pnh/ntpasswd/

You could also, assuming you had a backup, just delete the SAM file. This assumes you don't care about any of the accounts.
Forum: LIVE PLC Questions And Answers October 12th, 2018, 02:14 PM
Replies: 4
Views: 156
Posted By Dravik
I have had to reflash a panel(with the same...

I have had to reflash a panel(with the same version as before) that did that to me.
Forum: LIVE PLC Questions And Answers October 3rd, 2018, 09:56 AM
Replies: 9
Views: 404
Posted By Dravik
Regulatory and AHJ requirements outside of normal...

Regulatory and AHJ requirements outside of normal compliance requirements. (IE, for example compliance with CFR 21 Part 11 for Pharma industries)

Safety requirements
Ergonomic Requirements...
Forum: LIVE PLC Questions And Answers October 2nd, 2018, 02:41 PM
Replies: 4
Views: 177
Posted By Dravik
Yes but it depends on what you want to do w/ it. ...

Yes but it depends on what you want to do w/ it.
Just start/stop via digital i/o and feed it an analog speed ref, no worries.
Forum: LIVE PLC Questions And Answers October 2nd, 2018, 11:39 AM
Replies: 8
Views: 211
Posted By Dravik
Have you put a scope on the sensor itself?

Have you put a scope on the sensor itself?
Forum: LIVE PLC Questions And Answers October 2nd, 2018, 11:03 AM
Replies: 8
Views: 211
Posted By Dravik
So, depending on your de-bounce time, probably...

So, depending on your de-bounce time, probably fine there.
If I didn't have a high-speed counter module, I would probably put some secondary logic in to count the number of time the sensor goes...
Forum: LIVE PLC Questions And Answers October 2nd, 2018, 10:28 AM
Replies: 8
Views: 211
Posted By Dravik
How fast does your sensor switch? At 200ft/min...

How fast does your sensor switch? At 200ft/min how long is your part in front of the sensor for?

Edit: What is the RPI of this module set to and what kind of task is your counting logic executing...
Forum: LIVE PLC Questions And Answers October 1st, 2018, 03:14 PM
Replies: 1
Views: 128
Posted By Dravik
Sure, here you go.

Sure, here you go.
Forum: LIVE PLC Questions And Answers September 28th, 2018, 11:19 AM
Replies: 15
Views: 831
Posted By Dravik
Ahh fun, yeah if no server is listed, no ldap...

Ahh fun, yeah if no server is listed, no ldap funtimes.

I'd guess the username/passwords you have are actually local users. So yeah, those would work w/out the connection.

I don't think these...
Forum: LIVE PLC Questions And Answers September 26th, 2018, 03:26 PM
Replies: 15
Views: 831
Posted By Dravik
Well, and they may not have setup individual...

Well, and they may not have setup individual users in the directory. They may just be referencing windows-linked groups which may or may not display the domain.

Honestly, I would look at the...
Forum: LIVE PLC Questions And Answers September 26th, 2018, 12:59 PM
Replies: 15
Views: 831
Posted By Dravik
Well, the domain name is part of the username and...

Well, the domain name is part of the username and should be part of the factorytalk directory associated w/ the project, So if you load that AND the directory you should be able to see those
Forum: LIVE PLC Questions And Answers September 25th, 2018, 02:34 PM
Replies: 15
Views: 831
Posted By Dravik
Oh, those are on the rockwell knowledge base....

Oh, those are on the rockwell knowledge base. https://rockwellautomation.custhelp.com

You'll have to sign up for acct if you don't have one, but I think those answers are open to all.
Forum: LIVE PLC Questions And Answers September 25th, 2018, 02:21 PM
Replies: 14
Views: 317
Posted By Dravik
So, The 'STRING' datatype has 2 submembers (.len...

So, The 'STRING' datatype has 2 submembers (.len a DINT and .data a SINT[82])

The output tag of the 1734-232asc module has 4 submember (2 around transmit number, .length a SINT and .data a...
Forum: LIVE PLC Questions And Answers September 25th, 2018, 10:28 AM
Replies: 15
Views: 831
Posted By Dravik
Also, answer 1053276 for troubleshooting. If...

Also, answer 1053276 for troubleshooting.

If not, check out https://literature.rockwellautomation.com/idc/groups/literature/documents/um/viewme-um004_-en-e.pdf around page 258.
Forum: LIVE PLC Questions And Answers September 25th, 2018, 10:24 AM
Replies: 15
Views: 831
Posted By Dravik
Ah, so the PVP7, Do you have techconnect? If...

Ah, so the PVP7, Do you have techconnect?

If so, answer id 609098 describes the process really well.
Forum: LIVE PLC Questions And Answers September 25th, 2018, 09:04 AM
Replies: 15
Views: 831
Posted By Dravik
That's a complicated question. Short answer...

That's a complicated question.

Short answer is the LDAP query is usually setup to point at the directory server. If you wanted to do this locally, you would need to be running a local directory...
Forum: LIVE PLC Questions And Answers September 24th, 2018, 01:37 PM
Replies: 14
Views: 317
Posted By Dravik
No worries, this is how we learn. I do...

No worries, this is how we learn.

I do recommend getting familiar with hyperterminal or putty however. A breakout box/tester is also really useful
There is still a LOT of kit out there that uses...
Forum: LIVE PLC Questions And Answers September 24th, 2018, 11:21 AM
Replies: 14
Views: 317
Posted By Dravik
The short version is - You write the string...

The short version is -

You write the string you want into the output data of the module and then increment the transaction number to transmit it.

It is a little trickier as the output data I...
Forum: LIVE PLC Questions And Answers September 24th, 2018, 08:47 AM
Replies: 14
Views: 317
Posted By Dravik
in production, You will use the 1734-232asc...

in production, You will use the 1734-232asc module to send string commands to the display in order to control it.

For that, you'll want to grab the manual for that module and lookup the ascii...
Forum: LIVE PLC Questions And Answers September 24th, 2018, 07:26 AM
Replies: 14
Views: 317
Posted By Dravik
So no, You don't 'need' another piece of...

So no, You don't 'need' another piece of software. But it will make life easier for testing if you do...
The display just takes ascii commands via serial.

So, The first thing to do is just use...
Forum: LIVE PLC Questions And Answers September 11th, 2018, 03:43 PM
Replies: 2
Views: 203
Posted By Dravik
That is a project archive file. Open CCW and do...

That is a project archive file. Open CCW and do 'Import project'

You may have a different version or the file could be corrupted if that doesn't work.
Forum: LIVE PLC Questions And Answers September 7th, 2018, 12:26 PM
Replies: 4
Views: 363
Posted By Dravik
:thumb:

:thumb:
Forum: LIVE PLC Questions And Answers September 7th, 2018, 12:26 PM
Replies: 8
Views: 204
Posted By Dravik
Couple of things - The USB to serial will show...

Couple of things -
The USB to serial will show up as a com port in Device Manager, It probably won't be Com1. It might also change port #s if you move it around.

You'll want to use the DF1...
Forum: LIVE PLC Questions And Answers September 7th, 2018, 07:54 AM
Replies: 4
Views: 363
Posted By Dravik
Is that connection setup as Multicast or Unicast?...

Is that connection setup as Multicast or Unicast?

Multicast connections will not route across gateways w/out further configuration on the Network end.
Forum: LIVE PLC Questions And Answers September 6th, 2018, 06:56 AM
Replies: 8
Views: 487
Posted By Dravik
I've used iFix 5 keys to run 4.5, but I've never...

I've used iFix 5 keys to run 4.5, but I've never tried it w/ 2.5.
Reasonable chance the 3.0 keys will run the 2.5 software but no guarantee.