Search: Posts Made By: mendonsy
Forum: LIVE PLC Questions And Answers December 12th, 2018, 11:09 AM
Replies: 16
Views: 541
Posted By mendonsy
Eldon enclosures are a Rittal clone but are less...

Eldon enclosures are a Rittal clone but are less expensive. I also use Saginaw for NEMA 4 and 12. I haven't had any quality issues with either brand. Factorymation sells both of them.
Forum: LIVE PLC Questions And Answers December 10th, 2018, 10:25 AM
Replies: 16
Views: 458
Posted By mendonsy
I have always used a cleverly hidden toggle...

I have always used a cleverly hidden toggle switch object to toggle LB9062 on/off. If you just want to directly set the date and time, you can use numeric entry objects to set the values in...
Forum: LIVE PLC Questions And Answers November 28th, 2018, 03:21 PM
Replies: 4
Views: 170
Posted By mendonsy
Those are both made by Datcon. The oil sender is...

Those are both made by Datcon. The oil sender is a variable resistor. The temp sensor doesn't say what it is, but it appears that both connect to ground. They suggest that you contact a dealer....
Forum: LIVE PLC Questions And Answers November 23rd, 2018, 09:11 AM
Replies: 12
Views: 193
Posted By mendonsy
Another approach is to have a scheduled task that...

Another approach is to have a scheduled task that runs once every second (or minute) based on the internal clock bits P_1s or P_1min. With a task of this type you can do whatever is needed at a fixed...
Forum: LIVE PLC Questions And Answers November 22nd, 2018, 01:40 PM
Replies: 12
Views: 193
Posted By mendonsy
The TIML(553) instruction is supported for the...

The TIML(553) instruction is supported for the CP1E using CX-Programmer v9.6. Not sure why you would be having a problem using it.
Forum: LIVE PLC Questions And Answers November 21st, 2018, 02:33 PM
Replies: 22
Views: 1,093
Posted By mendonsy
Here's a similar but less expensive alternative...

Here's a similar but less expensive alternative to the Omron.
https://www.factorymation.com/SG2-10HR-A
I have had good luck with using them for small projects.
Forum: LIVE PLC Questions And Answers November 19th, 2018, 01:32 PM
Replies: 4
Views: 158
Posted By mendonsy
You will either need a crossover cable if...

You will either need a crossover cable if connecting directly to a PC or a switch if connecting through a network. You will also need to be sure that the IP address of the PC and HMI are in the same...
Forum: LIVE PLC Questions And Answers November 8th, 2018, 08:39 AM
Replies: 2
Views: 337
Posted By mendonsy
I don't know of a supplier, but I have made my...

I don't know of a supplier, but I have made my own version of this by using a small 12 volt DC power supply with a DC relay wired in series to the probe. When the probe makes continuity it closes the...
Forum: LIVE PLC Questions And Answers November 7th, 2018, 04:36 PM
Replies: 4
Views: 194
Posted By mendonsy
It appears that T23 will only be on for one scan....

It appears that T23 will only be on for one scan. If the first line of rung 13 is true during that scan then T21 will remain on.
Forum: LIVE PLC Questions And Answers November 1st, 2018, 07:33 PM
Replies: 2
Views: 161
Posted By mendonsy
Converting floating point (REAL) to BCD requires...

Converting floating point (REAL) to BCD requires two steps. You must first use the FIX instruction to convert the floating point value to binary (INT) then use the BCD instruction to convert the...
Forum: LIVE PLC Questions And Answers October 31st, 2018, 02:02 PM
Replies: 12
Views: 686
Posted By mendonsy
Would pressure sensitive safety mats work???

Would pressure sensitive safety mats work???
Forum: LIVE PLC Questions And Answers October 29th, 2018, 09:55 PM
Replies: 19
Views: 1,360
Posted By mendonsy
I made some guides for my jigsaw to get straight...

I made some guides for my jigsaw to get straight cuts without scratches. They are two pieces of 1/4" plate with a 1/8" gap between them. I added some key stock guides to keep the saw centered and...
Forum: LIVE PLC Questions And Answers October 22nd, 2018, 02:07 PM
Replies: 13
Views: 591
Posted By mendonsy
I have two different versions made by T&B. Both...

I have two different versions made by T&B. Both work well.
Forum: LIVE PLC Questions And Answers October 4th, 2018, 09:27 AM
Replies: 8
Views: 414
Posted By mendonsy
If there is any possibility of stray voltage on a...

If there is any possibility of stray voltage on a digital signal line it is best to install an interposing relay between the wire and the PLC. It is much better to toast a $10 relay than to damage a...
Forum: LIVE PLC Questions And Answers September 12th, 2018, 10:21 AM
Replies: 19
Views: 738
Posted By mendonsy
I suspect that the problem is probably in the...

I suspect that the problem is probably in the device driver that EZwarePlus loads for your PLC. There have occasionally been similar problems with the Omron drivers.
Forum: LIVE PLC Questions And Answers September 10th, 2018, 09:30 PM
Replies: 16
Views: 875
Posted By mendonsy
I suspect you will also need to be concerned...

I suspect you will also need to be concerned about the amount of heat that the motor will generate with all the starting and stopping. It will probably at least need a constant running cooling fan.
Forum: LIVE PLC Questions And Answers August 26th, 2018, 09:28 PM
Replies: 13
Views: 1,181
Posted By mendonsy
Check crane control suppliers. There are several...

Check crane control suppliers. There are several companies that make radio remote controls for overhead cranes. I have used Conductrix brand, but there are several others that make similar equipment.
Forum: LIVE PLC Questions And Answers August 26th, 2018, 01:43 PM
Replies: 10
Views: 1,039
Posted By mendonsy
That would be my guess also. It is fairly common...

That would be my guess also. It is fairly common for inductive sensors to have high leakage currents and require a load resistor.
Forum: LIVE PLC Questions And Answers August 24th, 2018, 01:55 PM
Replies: 77
Views: 2,758
Posted By mendonsy
How are you communicating with the PLC? If using...

How are you communicating with the PLC? If using Ethernet, did you set the HMI's IP address?
Forum: LIVE PLC Questions And Answers August 16th, 2018, 04:11 PM
Replies: 13
Views: 746
Posted By mendonsy
This chart seems to cover most sizes. ...

This chart seems to cover most sizes.
https://1xtechnologies.com/mm-to-awg/
Forum: LIVE PLC Questions And Answers August 16th, 2018, 10:19 AM
Replies: 5
Views: 431
Posted By mendonsy
You must create a data sampling object which...

You must create a data sampling object which captures all of the registers you want and stores them somewhere(HMI memory, USB, SD card). You can then create a trend display for that data sampling...
Forum: LIVE PLC Questions And Answers July 28th, 2018, 09:02 PM
Replies: 12
Views: 860
Posted By mendonsy
You could also try a resistor from the plc input...

You could also try a resistor from the plc input to the 24vdc common. Sometimes the PLC circuit doesn't conduct enough current to keep the prox running. A resistor (maybe 2.2 to 4.7k) might be just...
Forum: LIVE PLC Questions And Answers July 26th, 2018, 11:53 AM
Replies: 26
Views: 1,420
Posted By mendonsy
Autonics makes an off delay timer (AT8PMN) which...

Autonics makes an off delay timer (AT8PMN) which has an adjustable delay of up to 10 minutes after power is removed....
Forum: LIVE PLC Questions And Answers July 25th, 2018, 09:37 AM
Replies: 11
Views: 829
Posted By mendonsy
Keeping the physical distance (wire length)...

Keeping the physical distance (wire length) between the solenoid coil and the arc suppressor as short as possible will also help to reduce the spike.
Forum: LIVE PLC Questions And Answers July 7th, 2018, 08:55 PM
Replies: 12
Views: 1,049
Posted By mendonsy
If you are using a rack and pinion that would...

If you are using a rack and pinion that would mean the motor has to start and stop for each direction?? I doubt that a 7.5 hp gear motor is going to last long doing that.