Search: Posts Made By: Ih8Siemens
Forum: LIVE PLC Questions And Answers April 17th, 2018, 12:56 PM
Replies: 6
Views: 287
Posted By Ih8Siemens
That helps a lot, thanks. I do not have an option...

That helps a lot, thanks. I do not have an option to have a computer in the mix (it is a remote skid) so serial printer and HMI might be the only options. any recommendations for a printer? It just...
Forum: LIVE PLC Questions And Answers April 17th, 2018, 10:12 AM
Replies: 4
Views: 293
Posted By Ih8Siemens
how are you monitoring that current?

how are you monitoring that current?
Forum: LIVE PLC Questions And Answers April 17th, 2018, 10:08 AM
Replies: 2
Views: 193
Posted By Ih8Siemens
Well the easiest way to share would be to create...

Well the easiest way to share would be to create runtime application (If machine edition)

send the .mer to your friend

they use application manager (integrated within FT Studio under tools) and...
Forum: LIVE PLC Questions And Answers April 17th, 2018, 10:04 AM
Replies: 6
Views: 287
Posted By Ih8Siemens
Siemens S7 Printing instrumentation levels

I am wondering (since searching for material came up short) if anyone has some in sigh as to how I can print instrumentation levels from a Siemens S7.

ie: Process is a water purification skid...
Forum: LIVE PLC Questions And Answers March 8th, 2018, 09:44 PM
Replies: 26
Views: 1,580
Posted By Ih8Siemens
Hahaha, oh i grasp Siemens! I grasp their...

Hahaha, oh i grasp Siemens! I grasp their equipment and throw them off oil tanks!
(StuxNet proved that Siemens couldnt handle a massive attack by two nation states! Never would have happen to RA...
Forum: LIVE PLC Questions And Answers March 8th, 2018, 09:39 PM
Replies: 4
Views: 351
Posted By Ih8Siemens
***Update*** The motor was in fact under...

***Update***
The motor was in fact under sized.... Someone is taking an *** chewing.
Forum: LIVE PLC Questions And Answers March 8th, 2018, 09:38 PM
Replies: 14
Views: 1,117
Posted By Ih8Siemens
The VFD itself is just an N700E from what I can...

The VFD itself is just an N700E from what I can gather. There are two but I lucked out and got them to replace with Powerflex drives.

As for the Hyundai drives there was no way to control them...
Forum: LIVE PLC Questions And Answers March 8th, 2018, 09:27 PM
Replies: 26
Views: 1,580
Posted By Ih8Siemens
Carlo, I was orignially going to college for IT...

Carlo, I was orignially going to college for IT networking and programming. When I switched gears after studying the StuxNet Virus to PLC's I got an internship over the summer. Depending on how...
Forum: LIVE PLC Questions And Answers March 8th, 2018, 09:21 PM
Replies: 26
Views: 1,580
Posted By Ih8Siemens
True, and mk42 I know you dont know me but...

True, and mk42 I know you dont know me but believe me when i say that there is NOTHING that will put me in Detroit!
Forum: LIVE PLC Questions And Answers March 8th, 2018, 12:39 AM
Replies: 9
Views: 332
Posted By Ih8Siemens
No problem, yeah they take actual reading which,...

No problem, yeah they take actual reading which, when panicking to get something fixed, is hard to do haha. Did you end up figuring it out?
Forum: LIVE PLC Questions And Answers March 8th, 2018, 12:37 AM
Replies: 4
Views: 351
Posted By Ih8Siemens
I didn't even think of that....I will have the...

I didn't even think of that....I will have the electricians on site check it out tomorrow.
Forum: LIVE PLC Questions And Answers March 7th, 2018, 11:13 PM
Replies: 4
Views: 351
Posted By Ih8Siemens
PowerFlex 753 OL Current Protection?

Hey fellas,

Been getting absolutely hammered this week with tons of cool and exciting new weird problems so here's another one that I believe I know the answer but would love some other ideas.
...
Forum: LIVE PLC Questions And Answers March 7th, 2018, 10:56 PM
Replies: 9
Views: 332
Posted By Ih8Siemens
Check pg65 of this manual. also check out these...

Check pg65 of this manual. also check out these other pages that might pertain to your situation.
pg 19, pg22, pg24, pg27, pg 35
...
Forum: LIVE PLC Questions And Answers March 7th, 2018, 10:50 PM
Replies: 3
Views: 402
Posted By Ih8Siemens
Well if you have some rockwell products I believe...

Well if you have some rockwell products I believe if you search your computer you will find an application called BOOP-DHCP Tool. Its fairly self explanitory but get your mac address off of that...
Forum: LIVE PLC Questions And Answers March 7th, 2018, 10:46 PM
Replies: 1
Views: 231
Posted By Ih8Siemens
I would first check that you actually cleared the...

I would first check that you actually cleared the fault. my next step, and I am not too familiar with those drives, but when you refer to "drive not enabling" are you saying that meaning it wont...
Forum: LIVE PLC Questions And Answers March 7th, 2018, 10:40 PM
Replies: 9
Views: 332
Posted By Ih8Siemens
http://www.plctalk.net/qanda/showthread.php?t=4608...

http://www.plctalk.net/qanda/showthread.php?t=46084

See if that guys post helps you out at all.
Forum: LIVE PLC Questions And Answers March 7th, 2018, 10:36 PM
Replies: 4
Views: 352
Posted By Ih8Siemens
http://literature.rockwellautomation.com/idc/group...

http://literature.rockwellautomation.com/idc/groups/literature/documents/um/1769-um002_-en-p.pdf

Scroll down to 3-11 or 3-12. I am not sure what instrumentation you are using but if you could post...
Forum: LIVE PLC Questions And Answers March 7th, 2018, 10:29 PM
Replies: 14
Views: 1,117
Posted By Ih8Siemens
Sorry GeoSpark I didn't see the rest of your...

Sorry GeoSpark I didn't see the rest of your post.
The layout is less than ideal. Basically we have a micro with ~59DI , ~24DO, ~8AI ~4AO.
The local I/O to the distributed I/O doesnt quite have a...
Forum: LIVE PLC Questions And Answers March 7th, 2018, 10:13 PM
Replies: 26
Views: 1,580
Posted By Ih8Siemens
mk42, yeah I wish I knew how much knowing the...

mk42, yeah I wish I knew how much knowing the process would benefit me before jumping into the career. Would have taken a few petroleum classes prior.
Forum: LIVE PLC Questions And Answers March 7th, 2018, 06:32 PM
Replies: 9
Views: 716
Posted By Ih8Siemens
Scotty13, Someone else correct me if I am wrong...

Scotty13, Someone else correct me if I am wrong but I believe I ran into a devastating issue with that exact rev.

21.03 is a security resilient version which what that means to you is that you...
Forum: LIVE PLC Questions And Answers March 7th, 2018, 06:25 PM
Replies: 26
Views: 1,580
Posted By Ih8Siemens
The oil fields in North Dakota ( I am sure Texas...

The oil fields in North Dakota ( I am sure Texas and off-shore as well) will always need I&E / PLC Programming.

People here can answer without hesitation that it definitely is worth it. But that...
Forum: LIVE PLC Questions And Answers March 7th, 2018, 06:04 PM
Replies: 0
Views: 169
Posted By Ih8Siemens
MicroLogix 1400 Controlling N700E Hyundai Drive

Well mis-communication has lead me to a point where my micro is no longer the proper controller for the application its currently being utilized in.

That aside I have a customer that NEEDS...
Forum: LIVE PLC Questions And Answers March 7th, 2018, 05:45 PM
Replies: 14
Views: 1,117
Posted By Ih8Siemens
Thanks for the replies everyone, (GeoSpark I saw...

Thanks for the replies everyone, (GeoSpark I saw those Flex 5000 on i think a RA webinar and cant wait to mess around with them). The responses have been unreal and I believe we are gonna roll with...
Forum: LIVE PLC Questions And Answers March 5th, 2018, 06:40 PM
Replies: 14
Views: 1,117
Posted By Ih8Siemens
Point I/O vs Flex I/O

Hey fellas,

Customer had originally requested our services to check the tank levels of 8 tanks then provide a permissive to two Worldwide Drives (junk). Well after completing the task the other...
Forum: LIVE PLC Questions And Answers March 5th, 2018, 08:59 AM
Replies: 9
Views: 716
Posted By Ih8Siemens
What version exactly do you have of 21.xx?

What version exactly do you have of 21.xx?