Search: Posts Made By: SNK
Forum: LIVE PLC Questions And Answers April 22nd, 2012, 06:50 AM
Replies: 14
Views: 5,135
Posted By SNK
Generally, The Totalizer should be read as a...

Generally,

The Totalizer should be read as a floating point variable through your communication option purchased with the Flowmeter,

For example, if the Flowmeter was purchased with HART, then...
Forum: LIVE PLC Questions And Answers December 29th, 2011, 05:42 PM
Replies: 7
Views: 2,395
Posted By SNK
That is exactly how a system that I have worked...

That is exactly how a system that I have worked on functions.
Read the card, compare the PIN to an account, and bill accordingly.

(Any number of steps and sequences can be programmed in between...
Forum: LIVE PLC Questions And Answers June 26th, 2010, 07:42 PM
Replies: 5
Views: 1,220
Posted By SNK
Sounds like you may have duplicate Controlnet...

Sounds like you may have duplicate Controlnet addresses.
Check and re-check all of the addresses.
ControlNet is somewhat of a black-art when it comes to scheduling.
Go back to basics, and find out...
Forum: LIVE PLC Questions And Answers June 23rd, 2010, 06:42 PM
Replies: 1
Views: 2,765
Posted By SNK
I had a copy of Melsec Medoc once years back, and...

I had a copy of Melsec Medoc once years back, and it was installed under windows 95 operating system as well. Win95 OS had a different Shell/DOS package, and it would not migrate to w2k at the time....
Forum: LIVE PLC Questions And Answers June 12th, 2010, 07:20 AM
Replies: 6
Views: 2,479
Posted By SNK
Even though the original path was pointed to...

Even though the original path was pointed to RSLINX Via the DH+ driver, the new gateway would be pointing through the NEW Ethernet card, then to the DH+ networks. (This is how your gateway will be...
Forum: LIVE PLC Questions And Answers June 4th, 2010, 07:08 PM
Replies: 2
Views: 1,572
Posted By SNK
Where onto the "internet" are you sending...

Where onto the "internet" are you sending infomation?
(IP address?)
You need to use the flash application to setup your IP ports correctly.
Read the documentation that is supplied on the BB...
Forum: LIVE PLC Questions And Answers June 4th, 2010, 03:56 PM
Replies: 3
Views: 1,380
Posted By SNK
No Oil and Gas people that use Bristol out there?...

No Oil and Gas people that use Bristol out there?
Bump!
Forum: LIVE PLC Questions And Answers June 3rd, 2010, 05:09 PM
Replies: 3
Views: 1,380
Posted By SNK
Bristol Babcock CIP with AB communications

I am integrating a BB Controlwave processor with newer AB L5K platform, and need to make the 2 communicate reliably together.

The Bristol Babcock Controlwave product line datasheet indicates...
Forum: LIVE PLC Questions And Answers May 26th, 2010, 07:09 PM
Replies: 5
Views: 1,010
Posted By SNK
Not by chance a Getinge or Finn Aqua/Steris...

Not by chance a Getinge or Finn Aqua/Steris Autoclave?
Forum: LIVE PLC Questions And Answers May 14th, 2010, 08:21 PM
Replies: 35
Views: 3,867
Posted By SNK
You guys traveling over the border need to apply...

You guys traveling over the border need to apply for TN Visa's.
They are worth the hassle to get...I once waited for 4 hours, with my degree and paperwork in hand....but finally it was granted.
...
Forum: LIVE PLC Questions And Answers April 25th, 2010, 07:52 PM
Replies: 10
Views: 4,291
Posted By SNK
Seems quite straight forward from the video. It...

Seems quite straight forward from the video.
It is all hardware adapters, there is no software involved here....

But, seems ridiculous to go this route IMO.
Why not just grab the I/O from the...
Forum: LIVE PLC Questions And Answers April 17th, 2010, 09:38 AM
Replies: 1
Views: 823
Posted By SNK
Your question is vague at best.. Use GE InetII...

Your question is vague at best..
Use GE InetII 900 radio's simple, and work.
With the Inet's, there is some setup involved....
Have you followed the MFG's example?
Forum: LIVE PLC Questions And Answers April 14th, 2010, 04:54 PM
Replies: 9
Views: 3,207
Posted By SNK
Try to get Cognex involved. They are usually...

Try to get Cognex involved.
They are usually more than happy to provide details of past successful projects using particular processors..

Rick at RTA has a viable solution, it might be worthwhile...
Forum: LIVE PLC Questions And Answers April 7th, 2010, 07:22 PM
Replies: 9
Views: 3,207
Posted By SNK
Junior, I have communicated with various Cognex...

Junior, I have communicated with various Cognex products over the years with 5/05's only. (1000,3000, etc)

The problem is with the 5/04's, is that the MSG format that the Cognex is expecting is...
Forum: LIVE PLC Questions And Answers April 5th, 2010, 01:42 PM
Replies: 5
Views: 2,941
Posted By SNK
Type "keydiag" into the run command. This...

Type "keydiag" into the run command.

This will verify your information about the licensing for the key.
Post the results if you can.

If all else fails, re-install FIX32,
Reboot, and all of...
Forum: LIVE PLC Questions And Answers March 24th, 2010, 07:54 AM
Replies: 8
Views: 5,185
Posted By SNK
Help Files included in installation....

Help Files included in installation....
Forum: LIVE PLC Questions And Answers March 24th, 2010, 05:45 AM
Replies: 2
Views: 2,546
Posted By SNK
You need to get the basics. If you are...

You need to get the basics.
If you are connecting directly to the ENET module, then you would use a crossover cable. If you are going through your switch, then you need a std patch cable.

Your...
Forum: LIVE PLC Questions And Answers March 24th, 2010, 05:35 AM
Replies: 8
Views: 5,185
Posted By SNK
Based on your response, READ THE...

Based on your response,

READ THE DOCUMENTATION SUPPLIED WITH YOUR CD LAZY-BONES.
Forum: LIVE PLC Questions And Answers March 23rd, 2010, 06:56 PM
Replies: 2
Views: 1,702
Posted By SNK
The DF1 doesn't look right. What connection...

The DF1 doesn't look right.

What connection is this Display unit connected to? (You didn't mention that in your post)

The ML1500 only has one serial/DH-485 port, so you only have one choice of...
Forum: LIVE PLC Questions And Answers March 23rd, 2010, 06:44 PM
Replies: 8
Views: 5,185
Posted By SNK
There is an option to zip the project, called...

There is an option to zip the project, called Backup and Restore Wizard.
(It would have been installed in your Start/Programs)

Ask specific questions, and we will attempt to answer.
For...
Forum: LIVE PLC Questions And Answers March 22nd, 2010, 08:20 PM
Replies: 2
Views: 2,664
Posted By SNK
I would use an OPC server, similar to Kepserver,...

I would use an OPC server, similar to Kepserver, or others.
I would stay away from the IGS driver...
I have used the old drivers, and although they work, it would appear as though the OPC system...
Forum: LIVE PLC Questions And Answers March 19th, 2010, 07:23 PM
Replies: 2
Views: 1,287
Posted By SNK
Does it need to be RADAR? We have huge success...

Does it need to be RADAR?
We have huge success with Ultrasonic for massive volumes....
Forum: LIVE PLC Questions And Answers March 19th, 2010, 07:17 PM
Replies: 1
Views: 1,322
Posted By SNK
In order to do it the RIGHT way, you will need 2...

In order to do it the RIGHT way, you will need 2 NET-AIC modules, that can make your serial ports into DH-485 ports..... [/URL]

Below is a link to the 1761-NET-AIC manual
...
Forum: LIVE PLC Questions And Answers March 16th, 2010, 07:17 PM
Replies: 8
Views: 5,909
Posted By SNK
Thanks for the help guys, I think at this point,...

Thanks for the help guys, I think at this point, the best way to test is with real hardware.
Forum: LIVE PLC Questions And Answers March 15th, 2010, 06:55 PM
Replies: 8
Views: 5,909
Posted By SNK
Thanks for the advice, but our company...

Thanks for the advice, but our company standardized on Kepserver...