Search: Posts Made By: Eric Nelson
Forum: LIVE PLC Questions And Answers April 4th, 2017, 06:26 PM
Replies: 8
Views: 1,221
Posted By Eric Nelson
Then I would be thinking about something cheap...

Then I would be thinking about something cheap and disposable. Google 'digital angle gauge'. The ones woodworkers use to set up saw blades are only about $30 to $50. I'm sure you can figure out a way...
Forum: LIVE PLC Questions And Answers March 28th, 2017, 05:27 PM
Replies: 5
Views: 961
Posted By Eric Nelson
I'm guilty of making that mistake once. :o: ...

I'm guilty of making that mistake once. :o:

http://www.plctalk.net/qanda/showthread.php?t=92021

:beerchug:

-Eric
Forum: LIVE PLC Questions And Answers March 27th, 2017, 08:26 PM
Replies: 10
Views: 1,094
Posted By Eric Nelson
Did you try cmothebean's suggestion? Adding a NEQ...

Did you try cmothebean's suggestion? Adding a NEQ B3:1 0 after, and in addition to, your existing NEQ should prevent triggering your alarm screen when all bits are reset (B3:1 = zero).

To clarify,...
Forum: LIVE PLC Questions And Answers March 27th, 2017, 11:35 AM
Replies: 3
Views: 477
Posted By Eric Nelson
I did find THIS...

I did find THIS (https://www.manualslib.com/manual/1061231/Honeywell-Xenon-1900.html?page=242) which gives the pinouts. Note that it's a 10-pin RJ41, although an RJ-45 will likely work. Just remember...
Forum: LIVE PLC Questions And Answers March 23rd, 2017, 09:36 PM
Replies: 1
Views: 482
Posted By Eric Nelson
If you search for 'retentive' on the Crimson 3.0...

If you search for 'retentive' on the Crimson 3.0 Revision History page (LINK (http://www.redlion.net/crimson-30/revision-history)), build 530.000 lists 'Fixed G306K Retentive Memory Loss'. The G306K...
Forum: LIVE PLC Questions And Answers March 22nd, 2017, 03:07 PM
Replies: 2
Views: 881
Posted By Eric Nelson
You need to change your 'File' from #B3:1 to...

You need to change your 'File' from #B3:1 to #B3:0

Watch this video for a great explanation :thumb:

https://www.youtube.com/watch?v=ijsXGyNk0Ps

:beerchug:

-Eric
Forum: LIVE PLC Questions And Answers March 20th, 2017, 03:08 PM
Replies: 7
Views: 1,305
Posted By Eric Nelson
I'm guessing you're looking for a replacement? If...

I'm guessing you're looking for a replacement? If you Google 'remote capillary thermostat', you will find many similar items. For example:

http://www.alliedelec.com/selco-cap-85-230/70098641/
...
Forum: LIVE PLC Questions And Answers March 10th, 2017, 10:31 PM
Replies: 15
Views: 2,360
Posted By Eric Nelson
I have no experience with AD's newer Konnect-It...

I have no experience with AD's newer Konnect-It line, but I used their DINnector series for many years. I always felt the triple-level blocks were kinda flimsy.

If I recall correctly, they...
Forum: LIVE PLC Questions And Answers February 7th, 2017, 05:06 PM
Replies: 9
Views: 2,186
Posted By Eric Nelson
I have used the Omron D5C capacitive touch...

I have used the Omron D5C capacitive touch switches with good results. You probably want the 'free-attachment' version, so you can put your own actuator on it.
...
Forum: LIVE PLC Questions And Answers December 22nd, 2015, 02:51 PM
Replies: 6
Views: 979
Posted By Eric Nelson
Looking through the high-speed I/O instructions,...

Looking through the high-speed I/O instructions, I don't see anything that will allow you to send a continuous string of pulses. I remember needing a PWM for a project a while ago, and doing it with...
Forum: LIVE PLC Questions And Answers December 4th, 2015, 03:05 PM
Replies: 24
Views: 5,775
Posted By Eric Nelson
I have always used a set/reset method similar to...

I have always used a set/reset method similar to kwade's. I think a numeric step number is actually better, but I have been using this set/reset logic since the '80s, and it's hard to change. ;)
...
Forum: LIVE PLC Questions And Answers December 3rd, 2015, 11:40 AM
Replies: 4
Views: 734
Posted By Eric Nelson
Since you've decided to use modbus for normal...

Since you've decided to use modbus for normal operation, you should be fine. Looks like you've covered everything. :thumb:

EDIT: I usually set P6.03 to '1' to inhibit reverse operation.
...
Forum: LIVE PLC Questions And Answers December 2nd, 2015, 06:55 PM
Replies: 4
Views: 734
Posted By Eric Nelson
I've only used the GS1 and GS2 drives, but the...

I've only used the GS1 and GS2 drives, but the GS3 seems to be the same. I might have some time tomorrow to experiment with a GS2 drive I have on the shelf.

Unfortunately, I don't think you can...
Forum: LIVE PLC Questions And Answers August 18th, 2015, 06:52 PM
Replies: 14
Views: 4,843
Posted By Eric Nelson
From the 1610 manual, but it should be applicable...

From the 1610 manual, but it should be applicable to the 1520.

:beerchug:

-Eric
Forum: LIVE PLC Questions And Answers May 9th, 2015, 06:20 PM
Replies: 15
Views: 2,736
Posted By Eric Nelson
I heard that too, but the G304K2 I got from you...

I heard that too, but the G304K2 I got from you guys about 2 weeks ago did not have it enabled. Selling me old stock again? ;) :p

:beerchug:

-Eric
Forum: LIVE PLC Questions And Answers March 28th, 2015, 06:10 PM
Replies: 21
Views: 3,011
Posted By Eric Nelson
Could you add an additional sensor to ramp to a...

Could you add an additional sensor to ramp to a slow speed before reaching the 'in position' sensor? Or, using one sensor, allow the overshoot, then creep in reverse until the sensor turns off...
Forum: LIVE PLC Questions And Answers March 23rd, 2015, 11:58 AM
Replies: 17
Views: 1,746
Posted By Eric Nelson
I suspect that the XIO T4:2/EN in the 3rd rung is...

I suspect that the XIO T4:2/EN in the 3rd rung is resetting T4:1. While I'd expect the XIC T4:2/EN to already be on to maintain T4:2 in the following rung, the lack of the XIC T4:1/DN branch might...
Forum: LIVE PLC Questions And Answers March 21st, 2015, 01:29 AM
Replies: 10
Views: 1,183
Posted By Eric Nelson
Perhaps the original programmer had OPENs in that...

Perhaps the original programmer had OPENs in that location during debugging, then, instead of removing them, they simply changed them to SHORTs?

I find it amusing that, according to the PDF, both...
Forum: LIVE PLC Questions And Answers March 19th, 2015, 08:55 PM
Replies: 0
Views: 1,252
Posted By Eric Nelson
Editing Mutiple Motion Tasks in a Kollmorgen AKD over Modbus TCP/IP

I have three motion tasks (0, 1, and 2) in a Kollmorgen AKD-P00306 where I edit the 'Position' values with a G304K2 HMI. I have no problem with reading/writing individual parameters over Modbus, but...
Forum: LIVE PLC Questions And Answers March 16th, 2015, 01:47 AM
Replies: 27
Views: 7,125
Posted By Eric Nelson
In the many dozens of DL-series PLCs I've used, I...

In the many dozens of DL-series PLCs I've used, I have never, ever had an issue with lock-ups, or any communication issues for that matter. It just works! Although, I do have a real serial port on my...
Forum: LIVE PLC Questions And Answers January 5th, 2015, 12:49 PM
Replies: 4
Views: 1,383
Posted By Eric Nelson
I think I just used a 3 conductor shielded cable....

I think I just used a 3 conductor shielded cable. My G304K2 series has a different pinout than your G306, but that technote should be correct for which pins to use on the G306 end. Just don't use...
Forum: LIVE PLC Questions And Answers January 2nd, 2015, 03:20 PM
Replies: 4
Views: 1,383
Posted By Eric Nelson
I have successfully used a G304K2 with a Click,...

I have successfully used a G304K2 with a Click, so it WILL work.

Here are screenshots of the settings I used. See if yours match.

:beerchug:

-Eric
Forum: LIVE PLC Questions And Answers December 11th, 2014, 09:19 PM
Replies: 4
Views: 1,156
Posted By Eric Nelson
Thanks, Bernie. That makes sense. The contactor...

Thanks, Bernie. That makes sense. The contactor coils connected to two other outputs would give it that path to DC common. Since I realized my mistake immediately, I didn't bother checking voltages....
Forum: LIVE PLC Questions And Answers December 11th, 2014, 08:30 PM
Replies: 4
Views: 1,156
Posted By Eric Nelson
Thanks for the vote of confidence, Keith :thumb: ...

Thanks for the vote of confidence, Keith :thumb:

I would think the floating common should have no ill effects. I'm only concerned because it DID work a few times before staying high, which I...
Forum: LIVE PLC Questions And Answers December 11th, 2014, 07:45 PM
Replies: 4
Views: 1,156
Posted By Eric Nelson
ML1400 FET Outputs - Damaged, or Not?

1766-L32BXB. I screwed up and forgot to wire the COM2 terminal to DC- :shoot:

I cycled one of the outputs on and off a few times, and it was working, but then the output stayed on. The other...