You are not registered yet. Please click here to register!


 
 
plc storereviewsdownloads
This board is for PLC Related Q&A ONLY. Please DON'T use it for advertising, etc.
 
Try our online PLC Simulator- FREE.  Click here now to try it.

New Here? Please read this important info!!!


Go Back   PLCS.net - Interactive Q & A > Search Forums

Showing results 1 to 25 of 500
Search took 1.10 seconds.
Search: Posts Made By: MorphuisOGrady
Forum: LIVE PLC Questions And Answers March 1st, 2021, 06:46 AM
Replies: 39
Views: 5,823
Posted By MorphuisOGrady
Correct.

Correct.
Forum: LIVE PLC Questions And Answers March 1st, 2021, 04:45 AM
Replies: 39
Views: 5,823
Posted By MorphuisOGrady
+1 with VMWare Player. It's free and works...

+1 with VMWare Player.

It's free and works great. I have about 8 images that gives me all I need.
Forum: LIVE PLC Questions And Answers February 16th, 2021, 04:47 AM
Replies: 5
Views: 429
Posted By MorphuisOGrady
VBA will definitely get the job done. Have you...

VBA will definitely get the job done. Have you tried a literal string?

On the text object properties -> General -> /*LS:0 {#1}*/

In your parameter file #1 = Text you need to display
Forum: LIVE PLC Questions And Answers February 15th, 2021, 07:44 AM
Replies: 27
Views: 3,236
Posted By MorphuisOGrady
The keyswitch is your friend here. Turn to RUN.

The keyswitch is your friend here. Turn to RUN.
Forum: LIVE PLC Questions And Answers January 21st, 2021, 04:03 AM
Replies: 17
Views: 1,153
Posted By MorphuisOGrady
Who cares about Yaskawa? I posted this in...

Who cares about Yaskawa?

I posted this in the hope for a little digout regarding PF755 drives from Rockwell. I'm not going to swap the drives for A1000's just because they can do position control....
Forum: LIVE PLC Questions And Answers January 19th, 2021, 05:04 AM
Replies: 17
Views: 1,153
Posted By MorphuisOGrady
PF755 Drives for position control without motion

I have 5 x Powerflex 755 drives to position control in a non motion controller. Would anyone be able to point me to some links or sample applications how to:

1. Set up the Universal card for...
Forum: LIVE PLC Questions And Answers January 13th, 2021, 01:41 PM
Replies: 4
Views: 495
Posted By MorphuisOGrady
Simply because it's an electrically actuated...

Simply because it's an electrically actuated clamp and not a solenoid valve.

Sure it will fit the purpose but I was just curious if there was such an object in the library for a generic 2 state...
Forum: LIVE PLC Questions And Answers January 13th, 2021, 09:06 AM
Replies: 4
Views: 495
Posted By MorphuisOGrady
PlantPAx Object for Controlling 2 state device

Hi,

Anyone familiar with the PlantPAx library?

I have a few simple devices I need to control. 2 outputs for open/close and 2 inputs for status opened/closed.

I could use a P_Valve or P_Pump...
Forum: LIVE PLC Questions And Answers December 5th, 2020, 02:35 AM
Replies: 4
Views: 857
Posted By MorphuisOGrady
Put the controller in PROG mode and toggle...

Put the controller in PROG mode and toggle respective alarm trigger bits.
Forum: LIVE PLC Questions And Answers November 6th, 2020, 04:33 PM
Replies: 4
Views: 556
Posted By MorphuisOGrady
Thanks Ken for confirming. For some reason I...

Thanks Ken for confirming. For some reason I thought there was an 8MB option.

Unfortunately I have no space for a 1756 rack in this panel but I did not consider the 1769-AENTR as an option. Maybe...
Forum: LIVE PLC Questions And Answers November 6th, 2020, 04:15 PM
Replies: 4
Views: 556
Posted By MorphuisOGrady
Compactlogix Hardware

Hi,

What is the largest controller available in the Compactlogix series? Is it the 1769-L38ERM with 5MB work memory?

Also it there the possibility to add an additional Ethernet/IP bridge module...
Forum: LIVE PLC Questions And Answers October 25th, 2020, 06:54 PM
Replies: 29
Views: 3,050
Posted By MorphuisOGrady
If only this was the case I could live with it. I...

If only this was the case I could live with it. I am tortured with Whatsapp calls from colleagues and customers abroad. All they need to do is find my contact details on teams and then call me on...
Forum: LIVE PLC Questions And Answers October 14th, 2020, 08:06 AM
Replies: 10
Views: 1,001
Posted By MorphuisOGrady
How to approach a problem regarding position alignment

Hi,

I'm not looking for code but rather some suggestions on how to approach this problem. I can see myself writing messy code when surely there is a clean way to approach it.

I have 4 cylinders...
Forum: LIVE PLC Questions And Answers August 14th, 2020, 01:50 AM
Replies: 6
Views: 740
Posted By MorphuisOGrady
It is a basic HMI.

It is a basic HMI.
Forum: LIVE PLC Questions And Answers August 13th, 2020, 09:55 AM
Replies: 6
Views: 740
Posted By MorphuisOGrady
Thanks for the input. Anything from AB? Like a...

Thanks for the input. Anything from AB? Like a small 800 series?
Forum: LIVE PLC Questions And Answers August 13th, 2020, 08:10 AM
Replies: 6
Views: 740
Posted By MorphuisOGrady
Text Display Alternative for SLC500

I have an old Beijier text display which has failed in the field. This is long obsolete.

Can anyone suggest an alternative to interface to an SLC over Ethernet?

Only one connection required....
Forum: LIVE PLC Questions And Answers July 25th, 2020, 10:36 AM
Replies: 3
Views: 927
Posted By MorphuisOGrady
Controllogix Racks to offload

Hi all,

I understand this isnít a place to sell hardware so hopefully Iím allowed to to post.

I have a bunch of CLX racks comprising of L85E cpus, Ethernet modules, point I/O etc I have no need...
Forum: LIVE PLC Questions And Answers June 27th, 2020, 09:53 AM
Replies: 15
Views: 2,191
Posted By MorphuisOGrady
Non Trivial? That statement is complete bollocks.

Non Trivial? That statement is complete bollocks.
Forum: LIVE PLC Questions And Answers June 26th, 2020, 07:25 AM
Replies: 15
Views: 2,191
Posted By MorphuisOGrady
Do they even have an Emulator yet for the 5580...

Do they even have an Emulator yet for the 5580 series?
Forum: LIVE PLC Questions And Answers June 26th, 2020, 05:20 AM
Replies: 15
Views: 2,191
Posted By MorphuisOGrady
Rockwell really sucks with emulation. I had...

Rockwell really sucks with emulation.

I had to create a new project. Paste all the UDTs, AOIs, tags, tasks in. Remove all IO references before I could download to an L7 or an emulator.
Forum: LIVE PLC Questions And Answers June 26th, 2020, 01:45 AM
Replies: 15
Views: 2,191
Posted By MorphuisOGrady
Testing a AB L83E Program without controller

Hi,

I have a program I need to modify offline and test prior to commissioning.

Its developed in Logix V30. I have no L8x controllers available and the emulator is not an option when I attempt...
Forum: LIVE PLC Questions And Answers June 3rd, 2020, 03:26 AM
Replies: 38
Views: 5,207
Posted By MorphuisOGrady
I have a commissioning trip to US on 1st July....

I have a commissioning trip to US on 1st July. Customer is refusing to delay it.

I'm both very doubtful and hopeful there is no flights from Europe to US in 3 weeks time.
Forum: LIVE PLC Questions And Answers April 28th, 2020, 08:39 AM
Replies: 36
Views: 4,039
Posted By MorphuisOGrady
10% would be sufficient. Strapping table sounds...

10% would be sufficient. Strapping table sounds interesting. I think there is an AOI in the PlantPAx library for a Strapping table application. Might be worth a shot.
Forum: LIVE PLC Questions And Answers April 27th, 2020, 02:39 PM
Replies: 36
Views: 4,039
Posted By MorphuisOGrady
Thanks a lot for all this great stuff. I'll try...

Thanks a lot for all this great stuff. I'll try and get stuck in tomorrow and absorb what I can.

Any suggestions for a differential pressure transmitter?

I can leave the temperature transmitter...
Forum: LIVE PLC Questions And Answers April 27th, 2020, 01:59 AM
Replies: 36
Views: 4,039
Posted By MorphuisOGrady
Hi all, Thank you so much for the input on...

Hi all,

Thank you so much for the input on this. Lots of great stuff here.


I'm sorry I didn't provide enough information.
I am controlling air flow.
I have no position feedback.
The...
Showing results 1 to 25 of 500

 
Forum Jump

All times are GMT -5. The time now is 11:45 PM.


.