Forum: LIVE PLC Questions And Answers
March 1st, 2021, 06:46 AM
|
Replies: 39
Views: 5,823
|
Forum: LIVE PLC Questions And Answers
March 1st, 2021, 04:45 AM
|
Replies: 39
Views: 5,823
|
Forum: LIVE PLC Questions And Answers
February 16th, 2021, 04:47 AM
|
Replies: 5
Views: 429
|
Forum: LIVE PLC Questions And Answers
February 15th, 2021, 07:44 AM
|
Replies: 27
Views: 3,236
|
Forum: LIVE PLC Questions And Answers
January 21st, 2021, 04:03 AM
|
Replies: 17
Views: 1,153
Who cares about Yaskawa?
I posted this in...
Who cares about Yaskawa?
I posted this in the hope for a little digout regarding PF755 drives from Rockwell. I'm not going to swap the drives for A1000's just because they can do position control....
|
Forum: LIVE PLC Questions And Answers
January 19th, 2021, 05:04 AM
|
Replies: 17
Views: 1,153
PF755 Drives for position control without motion
I have 5 x Powerflex 755 drives to position control in a non motion controller. Would anyone be able to point me to some links or sample applications how to:
1. Set up the Universal card for...
|
Forum: LIVE PLC Questions And Answers
January 13th, 2021, 01:41 PM
|
Replies: 4
Views: 495
Simply because it's an electrically actuated...
Simply because it's an electrically actuated clamp and not a solenoid valve.
Sure it will fit the purpose but I was just curious if there was such an object in the library for a generic 2 state...
|
Forum: LIVE PLC Questions And Answers
January 13th, 2021, 09:06 AM
|
Replies: 4
Views: 495
PlantPAx Object for Controlling 2 state device
Hi,
Anyone familiar with the PlantPAx library?
I have a few simple devices I need to control. 2 outputs for open/close and 2 inputs for status opened/closed.
I could use a P_Valve or P_Pump...
|
Forum: LIVE PLC Questions And Answers
December 5th, 2020, 02:35 AM
|
Replies: 4
Views: 857
|
Forum: LIVE PLC Questions And Answers
November 6th, 2020, 04:33 PM
|
Replies: 4
Views: 556
Thanks Ken for confirming. For some reason I...
Thanks Ken for confirming. For some reason I thought there was an 8MB option.
Unfortunately I have no space for a 1756 rack in this panel but I did not consider the 1769-AENTR as an option. Maybe...
|
Forum: LIVE PLC Questions And Answers
November 6th, 2020, 04:15 PM
|
Replies: 4
Views: 556
Compactlogix Hardware
Hi,
What is the largest controller available in the Compactlogix series? Is it the 1769-L38ERM with 5MB work memory?
Also it there the possibility to add an additional Ethernet/IP bridge module...
|
Forum: LIVE PLC Questions And Answers
October 25th, 2020, 06:54 PM
|
Replies: 29
Views: 3,050
|
Forum: LIVE PLC Questions And Answers
October 14th, 2020, 08:06 AM
|
Replies: 10
Views: 1,001
|
Forum: LIVE PLC Questions And Answers
August 14th, 2020, 01:50 AM
|
Replies: 6
Views: 740
|
Forum: LIVE PLC Questions And Answers
August 13th, 2020, 09:55 AM
|
Replies: 6
Views: 740
|
Forum: LIVE PLC Questions And Answers
August 13th, 2020, 08:10 AM
|
Replies: 6
Views: 740
Text Display Alternative for SLC500
I have an old Beijier text display which has failed in the field. This is long obsolete.
Can anyone suggest an alternative to interface to an SLC over Ethernet?
Only one connection required....
|
Forum: LIVE PLC Questions And Answers
July 25th, 2020, 10:36 AM
|
Replies: 3
Views: 927
Controllogix Racks to offload
Hi all,
I understand this isn’t a place to sell hardware so hopefully I’m allowed to to post.
I have a bunch of CLX racks comprising of L85E cpus, Ethernet modules, point I/O etc I have no need...
|
Forum: LIVE PLC Questions And Answers
June 27th, 2020, 09:53 AM
|
Replies: 15
Views: 2,191
|
Forum: LIVE PLC Questions And Answers
June 26th, 2020, 07:25 AM
|
Replies: 15
Views: 2,191
|
Forum: LIVE PLC Questions And Answers
June 26th, 2020, 05:20 AM
|
Replies: 15
Views: 2,191
Rockwell really sucks with emulation.
I had...
Rockwell really sucks with emulation.
I had to create a new project. Paste all the UDTs, AOIs, tags, tasks in. Remove all IO references before I could download to an L7 or an emulator.
|
Forum: LIVE PLC Questions And Answers
June 26th, 2020, 01:45 AM
|
Replies: 15
Views: 2,191
Testing a AB L83E Program without controller
Hi,
I have a program I need to modify offline and test prior to commissioning.
Its developed in Logix V30. I have no L8x controllers available and the emulator is not an option when I attempt...
|
Forum: LIVE PLC Questions And Answers
June 3rd, 2020, 03:26 AM
|
Replies: 38
Views: 5,207
|
Forum: LIVE PLC Questions And Answers
April 28th, 2020, 08:39 AM
|
Replies: 36
Views: 4,039
|
Forum: LIVE PLC Questions And Answers
April 27th, 2020, 02:39 PM
|
Replies: 36
Views: 4,039
|
Forum: LIVE PLC Questions And Answers
April 27th, 2020, 01:59 AM
|
Replies: 36
Views: 4,039
Hi all,
Thank you so much for the input on...
Hi all,
Thank you so much for the input on this. Lots of great stuff here.
I'm sorry I didn't provide enough information.
I am controlling air flow.
I have no position feedback.
The...
|