Search: Posts Made By: AustralIan
Forum: LIVE PLC Questions And Answers March 21st, 2019, 11:59 AM
Replies: 33
Views: 1,079
Posted By AustralIan
Micro830 can kind of sits inbetween the 810 and...

Micro830 can kind of sits inbetween the 810 and the 820 in terms of comms, but is slightly better in terms of memory.

Micro830 all variables are retained, like a MicroLogix, whereas Micro820, you...
Forum: LIVE PLC Questions And Answers March 20th, 2019, 05:43 PM
Replies: 33
Views: 1,079
Posted By AustralIan
Micro1100 has Ethernet where the 810 does not. I...

Micro1100 has Ethernet where the 810 does not. I would consider the Micro820 if you like Ethernet. Looking further, the Micro 810 doesn't support ANY Comms to a HMI apart from the 1.5" LCD you click...
Forum: LIVE PLC Questions And Answers March 20th, 2019, 03:47 PM
Replies: 8
Views: 351
Posted By AustralIan
I just looked up the TP instruction in the unity...

I just looked up the TP instruction in the unity pro standard block library document number 33002519.01.

It does indeed ignore any subsequent rising edges of the input signal once it has started...
Forum: LIVE PLC Questions And Answers March 20th, 2019, 02:39 PM
Replies: 8
Views: 351
Posted By AustralIan
XIC Enable ONS Ons_00 TOF Timer 5000 0 XIC...

XIC Enable ONS Ons_00 TOF Timer 5000 0

XIC Timer.DN OTE Pulse

The above is what I usually put. I would use the Timer.DN in the code rather than have the extra line. I think the error on this is...
Forum: LIVE PLC Questions And Answers March 20th, 2019, 06:47 AM
Replies: 17
Views: 808
Posted By AustralIan
You could get a small "PLC" for this, such as...

You could get a small "PLC" for this, such as Siemens Logo, Eaton Easy4, etc.
Forum: LIVE PLC Questions And Answers March 8th, 2019, 03:29 AM
Replies: 6
Views: 401
Posted By AustralIan
I would second Ken Moore's Suggestion of a...

I would second Ken Moore's Suggestion of a rockwell PLC. You could look at a CompactLogix, which have models that support up to 250 Ethernet/IP nodes. You could then scale down to 24 nodes...
Forum: LIVE PLC Questions And Answers March 7th, 2019, 05:01 PM
Replies: 16
Views: 825
Posted By AustralIan
Harmony XB4 would be my preference over a...

Harmony XB4 would be my preference over a touchscreen.
Forum: LIVE PLC Questions And Answers March 6th, 2019, 11:12 AM
Replies: 10
Views: 473
Posted By AustralIan
They also do one with a pot output...

They also do one with a pot output http://apcs.com/atp168.php
Forum: LIVE PLC Questions And Answers March 5th, 2019, 11:26 AM
Replies: 7
Views: 479
Posted By AustralIan
Find document 1756-RM087.

Find document 1756-RM087.
Forum: LIVE PLC Questions And Answers March 1st, 2019, 07:33 AM
Replies: 8
Views: 492
Posted By AustralIan
The drives I used were setup with nodeguarding...

The drives I used were setup with nodeguarding rather than heartbeat, and would stop if comms was lost.
Forum: LIVE PLC Questions And Answers February 28th, 2019, 11:31 AM
Replies: 8
Views: 492
Posted By AustralIan
Most VSD have a parameter to fault on comms loss....

Most VSD have a parameter to fault on comms loss.

For example DE11 from Eaton uses P-40 to stop, coast or trip when it doesn't see communication for the time set in P-36.
Forum: LIVE PLC Questions And Answers January 25th, 2019, 08:30 AM
Replies: 9
Views: 521
Posted By AustralIan
Fluke 5080A, etc. ...

Fluke 5080A, etc.
https://eu.flukecal.com/products/electrical-calibration/electrical-calibrators
Forum: LIVE PLC Questions And Answers January 22nd, 2019, 02:25 PM
Replies: 4
Views: 377
Posted By AustralIan
Thanks everyone for your thoughts so far. ...

Thanks everyone for your thoughts so far.

PLCOpenXML: This looks like the easiest way to get everything out in a "readable" format. I don't find it as easy as Rockwell's ladder syntax, but it can...
Forum: LIVE PLC Questions And Answers January 22nd, 2019, 07:35 AM
Replies: 13
Views: 731
Posted By AustralIan
I hope that in ten years time we tell the new guy...

I hope that in ten years time we tell the new guy that the software that looks after important machinery was so buggy that we could make statements like this. They won't believe us of course, so we...
Forum: LIVE PLC Questions And Answers January 21st, 2019, 05:43 PM
Replies: 4
Views: 377
Posted By AustralIan
CODESYS: Is there a way to generate Ladder / FBD code?

Hello,

So in RSLogix 5K I would be used to doing the following:
1. Double click the left of the rung, to bring the rung text editor, will be something like:
BST XIC BOOL1 NXB XIO BOOL2 BND XIC...
Forum: LIVE PLC Questions And Answers January 21st, 2019, 08:28 AM
Replies: 13
Views: 1,289
Posted By AustralIan
.. Or visit the UK?

.. Or visit the UK?
Forum: LIVE PLC Questions And Answers January 16th, 2019, 03:15 PM
Replies: 27
Views: 1,231
Posted By AustralIan
Oops!

Oops!
Forum: LIVE PLC Questions And Answers January 16th, 2019, 02:02 PM
Replies: 27
Views: 1,231
Posted By AustralIan
Is it possible your OEM speaks a foreign language...

Is it possible your OEM speaks a foreign language and copied ”ton mot de passe est rogue" into Google translate and then emailed you to say "your password is red"?
Forum: LIVE PLC Questions And Answers January 16th, 2019, 01:45 PM
Replies: 16
Views: 661
Posted By AustralIan
I think the 5069-L306ER + 5069-RTB64-SPRING is...

I think the 5069-L306ER + 5069-RTB64-SPRING is the cheapest Logix5000 processor at the moment, at least list price. I agree with others that a Logix5000 processor is likely what your customers use...
Forum: LIVE PLC Questions And Answers January 15th, 2019, 10:47 AM
Replies: 16
Views: 1,026
Posted By AustralIan
Found a manual for your motor (SEW doc...

Found a manual for your motor (SEW doc 24745332.pdf)
http://download.sew-eurodrive.com/download/pdf/24745332.pdf

5.10.2 shows a YY wiring diagram like this
Forum: LIVE PLC Questions And Answers January 15th, 2019, 10:33 AM
Replies: 16
Views: 1,026
Posted By AustralIan
Might be missing something, but I can't see the...

Might be missing something, but I can't see the jumper between the brown white and yellow to form the star point on the left hand side of the 230V winding....
Forum: LIVE PLC Questions And Answers January 14th, 2019, 11:10 AM
Replies: 7
Views: 383
Posted By AustralIan
for a 1024 PPR encoder, your scaling should be ...

for a 1024 PPR encoder, your scaling should be
0 = 0, 1023 = 359.6484375, 1024 = 360

Note that although you will never normally see 1024, you can use it for your scaling factor.
Forum: LIVE PLC Questions And Answers January 14th, 2019, 08:38 AM
Replies: 4
Views: 414
Posted By AustralIan
X - user defined A - alarm

X - user defined
A - alarm
Forum: LIVE PLC Questions And Answers January 4th, 2019, 01:11 PM
Replies: 23
Views: 1,389
Posted By AustralIan
It sounds like a requirement got confused...

It sounds like a requirement got confused somewhere. I agree that a sample diagram showing the connected devices would help, or rough General Arrangement.
Forum: LIVE PLC Questions And Answers January 4th, 2019, 03:59 AM
Replies: 13
Views: 799
Posted By AustralIan
Drive could mean DOL starter though.. Is...

Drive could mean DOL starter though..

Is there a Standard for this sort of thing?

There are perhaps a number of problems to resolve:
Things blatantly being called the wrong thing, such as a...