Search: Posts Made By: sigmadelta
Forum: LIVE PLC Questions And Answers Yesterday, 12:39 PM
Replies: 13
Views: 3,577
Posted By sigmadelta
Try creating a new project with an Unspecified...

Try creating a new project with an Unspecified S7-1200, and upload, or under "online access" try copy/paste.
Forum: LIVE PLC Questions And Answers June 16th, 2019, 01:54 PM
Replies: 19
Views: 8,538
Posted By sigmadelta
This is the only one I have. It should work ...

This is the only one I have. It should work

Send a screenshot of the problem you have trying to run the software.
Forum: LIVE PLC Questions And Answers June 14th, 2019, 05:20 AM
Replies: 1
Views: 115
Posted By sigmadelta
Here is a link to the SIMOREG DC MASTER Manuals: ...

Here is a link to the SIMOREG DC MASTER Manuals:

https://support.industry.siemens.com/cs/products?dtp=Manual&mfn=ps&pnid=13303&lc=en-US

And a link to the SIMOREG DCM DC drives:
...
Forum: LIVE PLC Questions And Answers June 14th, 2019, 05:06 AM
Replies: 2
Views: 134
Posted By sigmadelta
One way I can think if is to change your FC to an...

One way I can think if is to change your FC to an FB, and use a STAT for DSTBLK, and use the value from the instance DB.

Otherwise, you have to construct the pointer for #stringvalue (which would...
Forum: LIVE PLC Questions And Answers June 14th, 2019, 04:48 AM
Replies: 19
Views: 8,538
Posted By sigmadelta
This should be it... ...

This should be it...

https://ufile.io/eu2b99xt
Forum: LIVE PLC Questions And Answers June 12th, 2019, 10:35 PM
Replies: 1
Views: 155
Posted By sigmadelta
Try uploading from the PLC using STEP 7 V5.6: ...

Try uploading from the PLC using STEP 7 V5.6:

https://support.industry.siemens.com/cs/document/109761679/step-7-v5-6-sp1-step-7-professional-2017-sr1-trial-download?dti=0&lc=en-MA

If your...
Forum: LIVE PLC Questions And Answers June 12th, 2019, 07:33 AM
Replies: 24
Views: 628
Posted By sigmadelta
Yeah... correct all the errors in Simatic Manager...

Yeah... correct all the errors in Simatic Manager before importing/migrating.

I'll assume you're right-clicking the Blocks folder, and choosing "Check Block Consistency".
Forum: LIVE PLC Questions And Answers June 12th, 2019, 05:40 AM
Replies: 24
Views: 628
Posted By sigmadelta
No, these blocks are system blocks used by the...

No, these blocks are system blocks used by the program. You can't edit them - they're pre-written by Siemens.
Forum: LIVE PLC Questions And Answers June 12th, 2019, 04:56 AM
Replies: 24
Views: 628
Posted By sigmadelta
It's WinCC flexible Runtime - which is a...

It's WinCC flexible Runtime - which is a computer-based HMI. It should be a fairly straight-forward conversion to TIA Portal (WinCC Advanced RT). I did several of these conversions.

For the...
Forum: LIVE PLC Questions And Answers June 12th, 2019, 02:23 AM
Replies: 3
Views: 299
Posted By sigmadelta
If the communication and all your functions are...

If the communication and all your functions are working, I would just ignore the error and/or contact Kollmorgen and tell them they have a glitch in their GSDML file.
Forum: LIVE PLC Questions And Answers June 11th, 2019, 01:31 PM
Replies: 24
Views: 628
Posted By sigmadelta
The HMI would not be in the HWConfig, it would be...

The HMI would not be in the HWConfig, it would be an object in SIMATIC Manager. Did you get any messages about missing software packages when opening the project?
Forum: LIVE PLC Questions And Answers June 11th, 2019, 06:44 AM
Replies: 24
Views: 628
Posted By sigmadelta
I have done it, from V5.5 + WinCC flexible 2008...

I have done it, from V5.5 + WinCC flexible 2008 to TIA Portal V13 SP1, then in turn to V14 and V15. I had warnings in the conversion, where I had to compile in STEP 7 and WinCC flexible before doing...
Forum: LIVE PLC Questions And Answers June 11th, 2019, 06:03 AM
Replies: 3
Views: 299
Posted By sigmadelta
Try the following link for the GSDML files...

Try the following link for the GSDML files required for Profinet:

https://www.kollmorgen.com/en-us/query/AKD%20GSDML/

I think you have to make sure you get the right version of GSDML for the...
Forum: LIVE PLC Questions And Answers June 11th, 2019, 05:48 AM
Replies: 1
Views: 183
Posted By sigmadelta
Can you post a screenshot of the error(s)? ...

Can you post a screenshot of the error(s)?

Also, the part number of the safety module in slot 1.
Forum: LIVE PLC Questions And Answers June 10th, 2019, 09:50 AM
Replies: 15
Views: 412
Posted By sigmadelta
You can download the trial version for V5.6+SP1...

You can download the trial version for V5.6+SP1 here:

https://support.industry.siemens.com/cs/document/109761679/step-7-v5-6-sp1-step-7-professional-2017-sr1-trial-download?dti=0&lc=en-MA
...
Forum: LIVE PLC Questions And Answers June 10th, 2019, 09:38 AM
Replies: 5
Views: 192
Posted By sigmadelta
I can help. I have WinCC V6 and WinCC flexible.

I can help. I have WinCC V6 and WinCC flexible.
Forum: LIVE PLC Questions And Answers June 10th, 2019, 07:42 AM
Replies: 17
Views: 26,206
Posted By sigmadelta
See this thread: ...

See this thread:

http://www.plctalk.net/qanda/showthread.php?t=83166
Forum: LIVE PLC Questions And Answers June 10th, 2019, 06:12 AM
Replies: 28
Views: 773
Posted By sigmadelta
That doesn't make sense... The error you posted...

That doesn't make sense... The error you posted means you have a reference to DB10 in the running PLC program, but the DB10 that exists is too short.
Forum: LIVE PLC Questions And Answers June 10th, 2019, 05:17 AM
Replies: 28
Views: 773
Posted By sigmadelta
You're accessing DB10 somewhere in your program,...

You're accessing DB10 somewhere in your program, and DB10 doesn't exist in the PLC.

Do a cross reference for DB10 in your program, if you're not sure where it is used.
Forum: LIVE PLC Questions And Answers June 10th, 2019, 04:55 AM
Replies: 28
Views: 773
Posted By sigmadelta
Can you look post the screenshot of the...

Can you look post the screenshot of the diagnostic buffer, but with the "details on event" which are further down?

http://www.plctalk.net/qanda/attachment.php?attachmentid=51214&d=1560157389
Forum: LIVE PLC Questions And Answers June 10th, 2019, 04:18 AM
Replies: 28
Views: 773
Posted By sigmadelta
Then the DB is not right... check that it is...

Then the DB is not right... check that it is indeed an instance DB of FB11. You can see this in the properties of the DB.
Forum: LIVE PLC Questions And Answers June 8th, 2019, 11:28 PM
Replies: 4
Views: 381
Posted By sigmadelta
It is possible to download a trial version of...

It is possible to download a trial version of STEP 7 Professional (TIA Portal) or STEP 7 V5.6 TRIAL (often referred to as "Classic"). Which one you download will depend what variant of software was...
Forum: LIVE PLC Questions And Answers June 7th, 2019, 11:15 PM
Replies: 10
Views: 283
Posted By sigmadelta
Another thing is to make sure the Profibus cable...

Another thing is to make sure the Profibus cable shield is making proper contact with the Profibus connector or terminals. I've had this affect communications with the Profibus device in question,...
Forum: LIVE PLC Questions And Answers June 7th, 2019, 11:06 PM
Replies: 10
Views: 283
Posted By sigmadelta
Silly question, is the Profibus adapter on the...

Silly question, is the Profibus adapter on the VFD seated properly? I've had hours of troubleshooting an intermittent problem with a Siemens Profibus network, because one drive in a terribly remote...
Forum: LIVE PLC Questions And Answers June 7th, 2019, 02:31 PM
Replies: 10
Views: 283
Posted By sigmadelta
A network layout diagram would help. Make...

A network layout diagram would help.

Make sure your Profibus network or segment(s) are in straight-line Daisy chain fashion, and not in a split or star method.

Check the Profibus connector for...