You are not registered yet. Please click here to register!


 
 
plc storereviewsdownloads
This board is for PLC Related Q&A ONLY. Please DON'T use it for advertising, etc.
 
Try our online PLC Simulator- FREE.  Click here now to try it.

---------->>>>>Get FREE PLC Programming Tips

New Here? Please read this important info!!!


Go Back   PLCS.net - Interactive Q & A > Search Forums

Showing results 1 to 25 of 160
Search took 0.02 seconds.
Search: Posts Made By: iknowsomeplc
Forum: LIVE PLC Questions And Answers March 12th, 2019, 07:37 AM
Replies: 67
Views: 5,608
Posted By iknowsomeplc
Really classic Manglemender :)

Really classic Manglemender :)
Forum: LIVE PLC Questions And Answers March 11th, 2019, 11:58 PM
Replies: 67
Views: 5,608
Posted By iknowsomeplc
These links are not working for some reason. ...

These links are not working for some reason.
Here is the new link to check the designs https://teespring.com/stores/funny-logo-parody-shirts
Forum: LIVE PLC Questions And Answers March 11th, 2019, 03:37 PM
Replies: 8
Views: 949
Posted By iknowsomeplc
What I understood is Ecostruxure Control Expert...

What I understood is Ecostruxure Control Expert has a completely new licensing system which includes floating license also.
Unity Ver13 or 13.1 license will not work with it , you need to get an...
Forum: LIVE PLC Questions And Answers March 11th, 2019, 02:46 PM
Replies: 67
Views: 5,608
Posted By iknowsomeplc
Just made these designs... Check out and let me...

Just made these designs... Check out and let me know @5618 this is what you want?

Online Links below
https://www.amazon.com/dp/B07PKRGV6B
https://www.amazon.com/dp/B07PJLV15J...
Forum: LIVE PLC Questions And Answers March 11th, 2019, 12:36 PM
Replies: 67
Views: 5,608
Posted By iknowsomeplc
Smile Soooo many funny quotes:) I will try to make...

Soooo many funny quotes:)
I will try to make designs soon...

What about this?
" I speak ladder Logic Language"
" Ladder Logic - the ladder only to climb down - never to climb up!"
"Move that...
Forum: LIVE PLC Questions And Answers March 11th, 2019, 01:13 AM
Replies: 67
Views: 5,608
Posted By iknowsomeplc
Funny phrases a PLC Automation engineer want on a T-Shirt

Being an Automation Engineer for quiet long time, what will be some funny phrases you want to wear on a T-shirt? I recently developed a hobby to design some T-shirts. Any input welcome.
Forum: LIVE PLC Questions And Answers December 26th, 2012, 02:26 AM
Replies: 1
Views: 1,353
Posted By iknowsomeplc
Solved this issue. first 2 input words to NOC...

Solved this issue. first 2 input words to NOC module gives status and then next 2 words give speed feedback in REAL format. Similarly, first 2 output words from NOC module to drive give commands and...
Forum: LIVE PLC Questions And Answers December 24th, 2012, 01:16 AM
Replies: 1
Views: 1,314
Posted By iknowsomeplc
Redundancy in Vijeo Citect can be defined at many...

Redundancy in Vijeo Citect can be defined at many different levels.
<LI class=pSmartList1 value=1>I/O Server Redundancy...
Forum: LIVE PLC Questions And Answers December 24th, 2012, 01:12 AM
Replies: 1
Views: 1,353
Posted By iknowsomeplc
Powerflex drive communication with Modicon Quantum over Ethernet I/P

We are trying to control AB Powerflex 755 drive on Ethernet I/P prototocl with Quantum PLC with NOC module ( Ethernet I/P module). Not sure what is the input word and output word configuartion for...
Forum: LIVE PLC Questions And Answers January 23rd, 2012, 07:46 AM
Replies: 3
Views: 2,174
Posted By iknowsomeplc
Yes, it will work with 127.0.0.1 Ip address and...

Yes, it will work with 127.0.0.1 Ip address and 502 port configured in Citect. I have used many times.
Forum: LIVE PLC Questions And Answers January 23rd, 2012, 07:44 AM
Replies: 7
Views: 1,471
Posted By iknowsomeplc
Thank you all for the inputs. I'm thinking from...

Thank you all for the inputs.
I'm thinking from a system integrator or contractor point of view. Classification is required to allow me add/deduct some process steps ( small projects don't require...
Forum: LIVE PLC Questions And Answers January 22nd, 2012, 05:31 AM
Replies: 8
Views: 6,810
Posted By iknowsomeplc
In unity, make Temp.2 as EBOOL type and directly...

In unity, make Temp.2 as EBOOL type and directly use posite edge. So you can write the logic in one rung as shown below.

Temp.2
--|P|------------( ) Temp.3

EBOOL is enhanced BOOL which can...
Forum: LIVE PLC Questions And Answers January 22nd, 2012, 05:23 AM
Replies: 7
Views: 1,471
Posted By iknowsomeplc
Classification of Automation Project

I am classifying automation projects into small, medium and large categories. This calssification has to be done during tendering stage hence low level design details are not known. Can somebody...
Forum: LIVE PLC Questions And Answers December 13th, 2011, 05:18 AM
Replies: 1
Views: 1,365
Posted By iknowsomeplc
Vijoe Citect support LG K500 and K1000 series...

Vijoe Citect support LG K500 and K1000 series through serial via computer link module. You have to go to project editor> communication > express wizard and create/reuse IO Server, create new IO...
Forum: LIVE PLC Questions And Answers December 13th, 2011, 05:05 AM
Replies: 1
Views: 1,793
Posted By iknowsomeplc
When you plug in the USB cable at PLC and laptop...

When you plug in the USB cable at PLC and laptop end, there will be a popup message to install USB driver. Did you clicked next, next and installed the USB driver?
Forum: LIVE PLC Questions And Answers September 28th, 2011, 12:57 AM
Replies: 14
Views: 7,230
Posted By iknowsomeplc
@GeoffC , you are right, BOOL takes a byte ( i...

@GeoffC , you are right, BOOL takes a byte ( i thought it is a microprocessor architecture limitation to read and write bits faster !, is it as per IEC ? ) and the most common way to address a DDT...
Forum: LIVE PLC Questions And Answers February 12th, 2011, 01:12 AM
Replies: 4
Views: 2,062
Posted By iknowsomeplc
use DDE

use DDE
Forum: LIVE PLC Questions And Answers February 10th, 2011, 06:15 AM
Replies: 5
Views: 1,449
Posted By iknowsomeplc
I remember that some where in the documentation...

I remember that some where in the documentation it mentions that we can pass up to 255 parameters to a supergenie pop up page. If you are using A s s w i n function, maximum eight parameters only can...
Forum: LIVE PLC Questions And Answers January 31st, 2011, 07:13 AM
Replies: 7
Views: 2,887
Posted By iknowsomeplc
Use wireshark or ethereal to monitor your...

Use wireshark or ethereal to monitor your ethernet network and you can see if anything abnomal in the network. Also see there is a physical key on the cpu which is not in memory protect mode.
Forum: LIVE PLC Questions And Answers January 31st, 2011, 07:08 AM
Replies: 5
Views: 1,324
Posted By iknowsomeplc
There is no rule of thumb for scan time, as far...

There is no rule of thumb for scan time, as far as I know. In your example, use a counter input input so that you won't missany pulse at whatever scan time PLC takes. Actually your program should not...
Forum: LIVE PLC Questions And Answers January 16th, 2011, 05:23 AM
Replies: 5
Views: 1,519
Posted By iknowsomeplc
You need to write this cicode function, only if...

You need to write this cicode function, only if you are creating your own Alarm pages and want to scroll through the Alarms. If you are using the original Template from CSV_Include project ( or...
Forum: LIVE PLC Questions And Answers January 13th, 2011, 07:09 AM
Replies: 2
Views: 2,319
Posted By iknowsomeplc
Are you using the Citect's Database Exchange...

Are you using the Citect's Database Exchange Manager? have configured connection to your SQL database and successfully tested it? Then all data should be shown in runtime
Forum: LIVE PLC Questions And Answers January 13th, 2011, 06:45 AM
Replies: 5
Views: 1,519
Posted By iknowsomeplc
Its actually calling Cicode functions...

Its actually calling Cicode functions AlarmDspNext and AlarmDspPrev
Forum: LIVE PLC Questions And Answers January 13th, 2011, 02:32 AM
Replies: 15
Views: 4,760
Posted By iknowsomeplc
There is a startup guide for Unity Pro...

There is a startup guide for Unity Pro (http://www.schneider-electric.cn/downloads//85257689000007EE/All/CC539D99DC776078852576B2006B8991/$File/05-Unity-EN.pdf).
Old. published during 2004 . May be...
Forum: LIVE PLC Questions And Answers January 12th, 2011, 04:55 AM
Replies: 5
Views: 2,431
Posted By iknowsomeplc
RTD wiring diagram for TM2AMI4LT module is...

RTD wiring diagram for TM2AMI4LT module is attached.

TWDLCAA24DRF is compact type but support upto 4 extension modules
and 230 V AC power supply can be directly given to PLC

TWDLMDA20DTK is...
Showing results 1 to 25 of 160

 
Forum Jump

All times are GMT -5. The time now is 02:23 AM.


.