Forum: LIVE PLC Questions And Answers February 12th, 2019, 06:46 AM
Replies: 11
Views: 543
Posted By mjp123gp
Thanks for the help. After messing with it a...

Thanks for the help. After messing with it a little more I found out that most traffic between me and that CPU is being blocked at the firewall. Echo request is the only thing currently set to pass...
Forum: LIVE PLC Questions And Answers February 11th, 2019, 02:00 PM
Replies: 11
Views: 543
Posted By mjp123gp
Screenshots would be cool. I've tried both ways...

Screenshots would be cool. I've tried both ways and still can't get a connection. I'm still able to ping the cpu but can't find it in AS.

Another quick question. I have the original source code...
Forum: LIVE PLC Questions And Answers February 11th, 2019, 08:35 AM
Replies: 11
Views: 543
Posted By mjp123gp
So this won't work if connected through on...

So this won't work if connected through on different VLAN through router? I'm able to ping the processor from my desk but AS doesn't find the device. Is there another way to get this to work across...
Forum: LIVE PLC Questions And Answers January 4th, 2019, 07:38 PM
Replies: 6
Views: 373
Posted By mjp123gp
Thanks! Solution #2 in the first link you posted...

Thanks! Solution #2 in the first link you posted with the Harmony files is the one I was thinking about. I'll try them when I get back to the office Monday.
Forum: LIVE PLC Questions And Answers January 3rd, 2019, 12:28 PM
Replies: 6
Views: 373
Posted By mjp123gp
FTView Studio Slow Tag Browser

I'm working on a new project now and everytime I open the tag browser from an objects properties box to assign a tag, it the whole program freezes up for about 30 seconds. I've tried rebooting PC but...
Forum: LIVE PLC Questions And Answers December 24th, 2018, 07:23 AM
Replies: 24
Views: 1,524
Posted By mjp123gp
Should be able to connect with the ethernet...

Should be able to connect with the ethernet driver. I've never used a wifi converter but have used quite a few ethernet-Serial converters.
Forum: LIVE PLC Questions And Answers December 11th, 2018, 06:32 PM
Replies: 7
Views: 396
Posted By mjp123gp
Thanks! The explanation is kinda funny because...

Thanks! The explanation is kinda funny because that's exactly what started our issue. We're doing new construction on an existing system and the electrical contractor wired up a new flow meter...
Forum: LIVE PLC Questions And Answers December 11th, 2018, 04:04 PM
Replies: 7
Views: 396
Posted By mjp123gp
Thanks for the feedback. It led me to finding a...

Thanks for the feedback. It led me to finding a different technote showing the exact issue I was seeing. Link below for anyone else interested.
...
Forum: LIVE PLC Questions And Answers December 11th, 2018, 03:51 PM
Replies: 7
Views: 396
Posted By mjp123gp
Makes sense. But also brings up another question,...

Makes sense. But also brings up another question, why does my IF16 module only show 8 inputs? It's set to differential float.
Forum: LIVE PLC Questions And Answers December 11th, 2018, 03:06 PM
Replies: 7
Views: 396
Posted By mjp123gp
1756-IF16 Question

While troubleshooting an issue with an analog input card the other day, I removed the terminal block from the input card. Looking at the values in the program, everything went high to a value just...
Forum: LIVE PLC Questions And Answers November 6th, 2018, 08:39 PM
Replies: 9
Views: 509
Posted By mjp123gp
Thanks for the help everyone! I really appreciate...

Thanks for the help everyone! I really appreciate it. I'm going to order the parts and hopefully everything works out.
Forum: LIVE PLC Questions And Answers November 6th, 2018, 06:14 PM
Replies: 9
Views: 509
Posted By mjp123gp
I do have an open slot on backplane. I've found...

I do have an open slot on backplane. I've found the C200H-LK201-V1 used on eBay for around $90. Also found the IP007 for around $150. I've got the Allen-Bradley 9300-USB adapter cable and it's worked...
Forum: LIVE PLC Questions And Answers November 6th, 2018, 07:46 AM
Replies: 9
Views: 509
Posted By mjp123gp
Could I also use the C200H-IP007 peripheral...

Could I also use the C200H-IP007 peripheral interface with the CQM1-CIF02 cable for programming? It looks like this would plug into the port on the bottom of the processor. I'm trying to find the...
Forum: LIVE PLC Questions And Answers November 5th, 2018, 07:51 PM
Replies: 9
Views: 509
Posted By mjp123gp
Omron PLC Info Needed

I've got a customer with a printing machine that has an Omron C200H-CPU21-E and the processor is dead. I've got 120VAC but no status indicator lights, 24VDC output power, or anything else. I've found...
Forum: LIVE PLC Questions And Answers November 2nd, 2018, 07:38 PM
Replies: 7
Views: 594
Posted By mjp123gp
Funny you mentioned that. I was just thinking...

Funny you mentioned that. I was just thinking earlier that I haven't had to update any 32-bit databases in a while. I just imported an old APA yesterday so I can confirm it works.
I've always...
Forum: LIVE PLC Questions And Answers September 9th, 2018, 09:11 PM
Replies: 3
Views: 654
Posted By mjp123gp
I haven't used the IFM mentioned above but their...

I haven't used the IFM mentioned above but their other products are pretty solid. I've always used Cognex for vision and they work very well but are usually more expensive. When I was working field...
Forum: LIVE PLC Questions And Answers July 27th, 2018, 07:55 AM
Replies: 4
Views: 646
Posted By mjp123gp
No I hadn't tried that. Just tried an it worked....

No I hadn't tried that. Just tried an it worked. How would I upload the program if I don't have the offline copy? When I look at block in the accessible node list nothing shows up.
Thanks!
Forum: LIVE PLC Questions And Answers July 26th, 2018, 02:21 PM
Replies: 4
Views: 646
Posted By mjp123gp
Connect to Siemens via Ethernet

I'm trying to setup our Siemens PLC's so I can access them remotely via Ethernet but can't quite figure it out. I've got my PG setup and can see all the devices on the Accessible Nodes list. My issue...
Forum: LIVE PLC Questions And Answers June 1st, 2018, 10:14 PM
Replies: 15
Views: 1,096
Posted By mjp123gp
Thanks for all the info guys! Much appreciated!

Thanks for all the info guys! Much appreciated!
Forum: LIVE PLC Questions And Answers June 1st, 2018, 10:09 PM
Replies: 15
Views: 1,096
Posted By mjp123gp
I changed it in the controller properties.

I changed it in the controller properties.
Forum: LIVE PLC Questions And Answers May 30th, 2018, 10:57 PM
Replies: 15
Views: 1,096
Posted By mjp123gp
I ended up having to put the old processor back...

I ended up having to put the old processor back in due to other communication related issues but I'm going to attempt the replacement again next time I get a chance. Since the sample time affects the...
Forum: LIVE PLC Questions And Answers May 30th, 2018, 09:21 PM
Replies: 15
Views: 1,096
Posted By mjp123gp
PID Loop Update Match Execution Time

Today I upgraded an L55 processor with an L82, which ended up being the 2nd unsuccessful attempt but thats a different story. After starting the process back up we noticed a few of the pumps that try...
Forum: LIVE PLC Questions And Answers May 13th, 2018, 04:09 PM
Replies: 8
Views: 1,168
Posted By mjp123gp
Thanks for the reply. I'll check out that...

Thanks for the reply. I'll check out that document when I get back onsite tomorrow and see if there's anything that applies to our issue. We did have some issues with our SCADA as well which is iFix....
Forum: LIVE PLC Questions And Answers May 11th, 2018, 06:17 PM
Replies: 8
Views: 1,168
Posted By mjp123gp
Ours our conditioned with the MSG enable bit like...

Ours our conditioned with the MSG enable bit like you've shown and also have the timers so they're not executed every scan
Forum: LIVE PLC Questions And Answers May 10th, 2018, 09:30 PM
Replies: 8
Views: 1,168
Posted By mjp123gp
They're on timers. I just went back through and...

They're on timers. I just went back through and counted 47 message instructions being triggered by 30 different timers so I guess it's possible too many of them are being triggered at the same time.